49 research outputs found

    Utilization of mechanical power and associations with clinical outcomes in brain injured patients. a secondary analysis of the extubation strategies in neuro-intensive care unit patients and associations with outcome (ENIO) trial

    Get PDF
    BackgroundThere is insufficient evidence to guide ventilatory targets in acute brain injury (ABI). Recent studies have shown associations between mechanical power (MP) and mortality in critical care populations. We aimed to describe MP in ventilated patients with ABI, and evaluate associations between MP and clinical outcomes.MethodsIn this preplanned, secondary analysis of a prospective, multi-center, observational cohort study (ENIO, NCT03400904), we included adult patients with ABI (Glasgow Coma Scale <= 12 before intubation) who required mechanical ventilation (MV) >= 24 h. Using multivariable log binomial regressions, we separately assessed associations between MP on hospital day (HD)1, HD3, HD7 and clinical outcomes: hospital mortality, need for reintubation, tracheostomy placement, and development of acute respiratory distress syndrome (ARDS).ResultsWe included 1217 patients (mean age 51.2 years [SD 18.1], 66% male, mean body mass index [BMI] 26.3 [SD 5.18]) hospitalized at 62 intensive care units in 18 countries. Hospital mortality was 11% (n = 139), 44% (n = 536) were extubated by HD7 of which 20% (107/536) required reintubation, 28% (n = 340) underwent tracheostomy placement, and 9% (n = 114) developed ARDS. The median MP on HD1, HD3, and HD7 was 11.9 J/min [IQR 9.2-15.1], 13 J/min [IQR 10-17], and 14 J/min [IQR 11-20], respectively. MP was overall higher in patients with ARDS, especially those with higher ARDS severity. After controlling for same-day pressure of arterial oxygen/fraction of inspired oxygen (P/F ratio), BMI, and neurological severity, MP at HD1, HD3, and HD7 was independently associated with hospital mortality, reintubation and tracheostomy placement. The adjusted relative risk (aRR) was greater at higher MP, and strongest for: mortality on HD1 (compared to the HD1 median MP 11.9 J/min, aRR at 17 J/min was 1.22, 95% CI 1.14-1.30) and HD3 (1.38, 95% CI 1.23-1.53), reintubation on HD1 (1.64; 95% CI 1.57-1.72), and tracheostomy on HD7 (1.53; 95%CI 1.18-1.99). MP was associated with the development of moderate-severe ARDS on HD1 (2.07; 95% CI 1.56-2.78) and HD3 (1.76; 95% CI 1.41-2.22).ConclusionsExposure to high MP during the first week of MV is associated with poor clinical outcomes in ABI, independent of P/F ratio and neurological severity. Potential benefits of optimizing ventilator settings to limit MP warrant further investigation

    Massachusetts Institute of Technology Electric Vehicle Team Porsche designing a cooling system for the AC24 electric motor

    No full text
    Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.Cataloged from PDF version of thesis.Includes bibliographical references (p. 32-33).In this thesis I worked on the design and analysis of a cooling system for the electric motor of the MIT Electric Vehicle Team's Porsche 914 Battery Electric Vehicle. The vehicle's Azure Dynamics AC24 motor tended to overheat (up to around 140C), which caused the motor controller to limit the maximum power of the motor. The maximum operating temperature of the motor is listed as 55C. The power limitation prevented the vehicle from achieving its top possible speeds, reaching only 87mph when it should get to over 100mph. To solve this problem, I designed a heat-exchanger system that runs coolant (a mix of water and ethylene glycol) through aluminum passages over the motor surface. The coolant then enters a heat-sink apparatus which consists of winding copper pipes attached to an aluminum array of fins (the heat sink) which convect away the heat into the moving ambient air. I found that with this system, at an ambient temperature of 50C, the maximum motor temperature would be about 72.61C. Even if the air temperature is 32C (89.6F), the maximum motor temperature will only be 54.7C, which is within the listed operating temperature of the motor and meets our goal. The total cost of this system is estimated to be $646.91.by Jordan N. Meenen.S.B

    Hydroxyapatite-ceramic for juxta-articular implantation

    No full text

    Histologische Untersuchungen nach autologer osteochondraler Transplantation

    No full text

    Fully automated postoperative ventilation in cardiac surgery patients: a randomised clinical trial

    No full text
    Background: Ensuring that lung-protective ventilation is achieved at scale is challenging in perioperative practice. Fully automated ventilation may be more effective in delivering lung-protective ventilation. Here, we compared automated lung-protective ventilation with conventional ventilation after elective cardiac surgery in haemodynamically stable patients. Methods: In this single-centre investigator-led study, patients were randomly assigned at the end of cardiac surgery to receive either automated (adaptive support ventilation) or conventional ventilation. The primary endpoint was the proportion of postoperative ventilation time characterised by exposure to predefined optimal, acceptable, and critical (injurious) ventilatory parameters in the first three postoperative hours. Secondary outcomes included severe hypoxaemia (SpO2 <85%) and resumption of spontaneous breathing. Data are presented as mean (95% confidence intervals [CIs]). Results: We randomised 220 patients (30.4% females; age: 62–76 yr). Subjects randomised to automated ventilation (n=109) spent a 29.7% (95% CI: 22.1–37.4) higher mean proportion of postoperative ventilation time receiving optimal postoperative ventilation after surgery (P<0.001) compared with subjects receiving conventional postoperative ventilation (n=111). Automated ventilation also reduced the proportion of postoperative ventilation time that subjects were exposed to injurious ventilatory settings by 2.5% (95% CI: 1–4; P=0.003). Severe hypoxaemia was less likely in subjects randomised to automated ventilation (risk ratio: 0.26 [0.22–0.31]; P<0.01). Subjects resumed spontaneous breathing more rapidly when randomised to automated ventilation (hazard ratio: 1.38 [1.05–1.83]; P=0.03). Conclusions: Fully automated ventilation in haemodynamically stable patients after cardiac surgery optimised lung-protective ventilation during postoperative ventilation, with fewer episodes of severe hypoxaemia and an accelerated resumption of spontaneous breathing. Clinical trial registration: NCT03180203

    Fully automated postoperative ventilation in cardiac surgery patients: a randomised clinical trial

    No full text
    Background: Ensuring that lung-protective ventilation is achieved at scale is challenging in perioperative practice. Fully automated ventilation may be more effective in delivering lung-protective ventilation. Here, we compared automated lung-protective ventilation with conventional ventilation after elective cardiac surgery in haemodynamically stable patients. Methods: In this single-centre investigator-led study, patients were randomly assigned at the end of cardiac surgery to receive either automated (adaptive support ventilation) or conventional ventilation. The primary endpoint was the proportion of postoperative ventilation time characterised by exposure to predefined optimal, acceptable, and critical (injurious) ventilatory parameters in the first three postoperative hours. Secondary outcomes included severe hypoxaemia (SpO 2 <85%) and resumption of spontaneous breathing. Data are presented as mean (95% confidence intervals [CIs]). Results: We randomised 220 patients (30.4% females; age: 62–76 yr). Subjects randomised to automated ventilation (n=109) spent a 29.7% (95% CI: 22.1–37.4) higher mean proportion of postoperative ventilation time receiving optimal postoperative ventilation after surgery (P<0.001) compared with subjects receiving conventional postoperative ventilation (n=111). Automated ventilation also reduced the proportion of postoperative ventilation time that subjects were exposed to injurious ventilatory settings by 2.5% (95% CI: 1–4; P=0.003). Severe hypoxaemia was less likely in subjects randomised to automated ventilation (risk ratio: 0.26 [0.22–0.31]; P<0.01). Subjects resumed spontaneous breathing more rapidly when randomised to automated ventilation (hazard ratio: 1.38 [1.05–1.83]; P=0.03). Conclusions: Fully automated ventilation in haemodynamically stable patients after cardiac surgery optimised lung-protective ventilation during postoperative ventilation, with fewer episodes of severe hypoxaemia and an accelerated resumption of spontaneous breathing. Clinical trial registration: NCT03180203

    Practice of Awake Prone Positioning in Critically Ill COVID-19 Patients—Insights from the PRoAcT–COVID Study

    Get PDF
    We describe the incidence, practice and associations with outcomes of awake prone positioning in patients with acute hypoxemic respiratory failure due to coronavirus disease 2019 (COVID-19) in a national multicenter observational cohort study performed in 16 intensive care units in the Netherlands (PRoAcT–COVID-study). Patients were categorized in two groups, based on received treatment of awake prone positioning. The primary endpoint was practice of prone positioning. Secondary endpoint was ‘treatment failure’, a composite of intubation for invasive ventilation and death before day 28. We used propensity matching to control for observed confounding factors. In 546 patients, awake prone positioning was used in 88 (16.1%) patients. Prone positioning started within median 1 (0 to 2) days after ICU admission, sessions summed up to median 12.0 (8.4–14.5) hours for median 1.0 day. In the unmatched analysis (HR, 1.80 (1.41–2.31); p p = 0.30), treatment failure occurred more often in patients that received prone positioning. The findings of this study are that awake prone positioning was used in one in six COVID-19 patients. Prone positioning started early, and sessions lasted long but were often discontinued because of need for intubation
    corecore