18 research outputs found

    Results of salt intake restriction monitored with the new sodium control biosensor

    Full text link
    Adherence to a low sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CareSystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor.A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CareSystem monitor with activation of the Na module. Total Na balance, pre/postdialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake.Restricted Na intake increased the percentage of patients on a low-sodium diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily sodium by more than 3 g Na/day lowered their systolic blood pressure.The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.S. Karger AG, Basel

    Large kidneys predict poor renal outcome in subjects with diabetes and chronic kidney disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Renal hypertrophy occurs early in diabetic nephropathy, its later value is unknown. Do large kidneys still predict poor outcome in patients with diabetes and Chronic Kidney Disease (CKD)?</p> <p>Methods</p> <p>Seventy-five patients with diabetes and CKD according to a Glomerular Filtration Rate (GFR, by 51Cr-EDTA clearance) below 60 mL/min/1.73 m<sup>2 </sup>or an Albumin Excretion Rate above 30 mg/24 H, had an ultrasound imaging of the kidneys and were cooperatively followed during five years by the Diabetology and Nephrology departments of the Centre Hospitalier Universitaire de Bordeaux.</p> <p>Results</p> <p>The patients were mainly men (44/75), aged 62 ± 13 yrs, with long-standing diabetes (duration:17 ± 9 yrs, 55/75 type 2), and CKD: initial GFR: 56.5 (8.5-209) mL/min/1.73 m<sup>2</sup>, AER: 196 (20-2358) mg/24 H. Their mean kidney lenght (108 ± 13 mm, 67-147) was correlated to the GFR (r = 0.23, p < 0.05). During the follow-up, 9/11 of the patients who had to start dialysis came from the half with the largest kidneys (LogRank: p < 0.05), despite a 40% higher initial isotopic GFR. Serum creatinine were initially lower (Small kidneys: 125 (79-320) μmol/L, Large: 103 (50-371), p < 0.05), but significantly increased in the "large kidneys" group at the end of the follow-up (Small kidneys: 129 (69-283) μmol/L, Large: 140 (50-952), p < 0.005 vs initial). The difference persisted in the patients with severe renal failure (KDOQI stages 4,5).</p> <p>Conclusions</p> <p>Large kidneys still predict progression in advanced CKD complicating diabetes. In these patients, ultrasound imaging not only excludes obstructive renal disease, but also provides information on the progression of the renal disease.</p

    La imagen de la semana

    No full text

    Supplementary Material for: Sensitivity of Blood Volume Monitoring for Fluid Status Assessment in Hemodialysis Patients

    No full text
    <b><i>Background/Aims:</i></b> This study investigates the use of blood volume monitoring (BVM) markers for the assessment of fluid status. <b><i>Methods:</i></b> Predialysis fluid overload (FO) and BVM data were collected in 55 chronic hemodialysis patients in 317 treatments. Predialysis FO was measured using bioimpedance spectroscopy. The slope of the intravascular volume decrease over time normalized by ultrafiltration rate (Slope4h) was used as the primary BVM marker and compared against FO. <b><i>Results:</i></b> Average relative blood volume curves were well separated in different FO groups between 0 and 5 liters. Receiver-operating characteristics analysis revealed that the sensitivity of BVM was moderate in median FO ranges between 1 and 3 liters (AUC 0.60-0.65), slightly higher for volume depletion of FO <1 liter (AUC 0.7) and highest for excess fluid of FO >3 liters (AUC 0.85). <b><i>Conclusion</i></b>: Devices that monitor blood volume are well suited to detect high FO, but are not as sensitive at moderate or low levels of fluid status
    corecore