2,006 research outputs found

    The dendritic pathologist

    Get PDF
    Click on the link to view

    Estimations of orbital parameters of exoplanets from transit photometry by using dynamical constraints

    Get PDF
    The probability of the detection of Earth-like exoplanets may increase in the near future after the launch of the space missions using the transit photometry as observation method. By using this technique only the semi-major axis of the detected planet can be determined, and there will be no information on the upper limit of its orbital eccentricity. However, the orbital eccentricity is a very important parameter, not only from a dynamical point of view, since it gives also information on the climate and the habitability of the Earth-like planets. In this paper a possible procedure is suggested for confining the eccentricity of an exoplanet discovered by transit photometry if an already known giant planet orbits also in the system.Comment: 16 pages, 10 figures, accepted for Cel. Mech. Dyn. Astro

    Stimulus statistics shape oscillations in nonlinear recurrent neural networks.

    Get PDF
    Rhythmic activity plays a central role in neural computations and brain functions ranging from homeostasis to attention, as well as in neurological and neuropsychiatric disorders. Despite this pervasiveness, little is known about the mechanisms whereby the frequency and power of oscillatory activity are modulated, and how they reflect the inputs received by neurons. Numerous studies have reported input-dependent fluctuations in peak frequency and power (as well as couplings across these features). However, it remains unresolved what mediates these spectral shifts among neural populations. Extending previous findings regarding stochastic nonlinear systems and experimental observations, we provide analytical insights regarding oscillatory responses of neural populations to stimulation from either endogenous or exogenous origins. Using a deceptively simple yet sparse and randomly connected network of neurons, we show how spiking inputs can reliably modulate the peak frequency and power expressed by synchronous neural populations without any changes in circuitry. Our results reveal that a generic, non-nonlinear and input-induced mechanism can robustly mediate these spectral fluctuations, and thus provide a framework in which inputs to the neurons bidirectionally regulate both the frequency and power expressed by synchronous populations. Theoretical and computational analysis of the ensuing spectral fluctuations was found to reflect the underlying dynamics of the input stimuli driving the neurons. Our results provide insights regarding a generic mechanism supporting spectral transitions observed across cortical networks and spanning multiple frequency bands

    Melanin-concentrating hormone in peripheral circulation in the human

    Get PDF
    Melanin-concentrating hormone (MCH) is a hypothalamic neuropeptide with a well-characterised role in energy homeostasis and emergent roles in diverse physiologic functions such as arousal, mood and reproduction. Work to date has predominantly focused on its hypothalamic functions using animal models; however, little attention has been paid to its role in circulation in humans. The aims of this study were to (a) develop a radioimmunoassay for the detection of MCH in human plasma; (b) establish reference ranges for circulating MCH and (c) characterise the pattern of expression of circulating MCH in humans. A sensitive and specific RIA was developed and cross-validated by RP-HPLC and MS. The effective range was 19.5–1248 pg MCH/mL. Blood samples from 231 subjects were taken to establish a reference range of 19.5–55.4 pg/mL for fasting MCH concentrations. There were no significant differences between male and female fasting MCH concentrations; however, there were correlations between MCH concentrations and BMI in males and females with excess fat (P < 0.001 and P = 0.020) and between MCH concentrations and fat mass in females with excess fat (P = 0.038). Plasma MCH concentrations rose significantly after feeding in a group of older individuals (n = 50, males P = 0.006, females P = 0.023). There were no robust significant correlations between fasting or post-prandial MCH and resting metabolic rate, plasma glucose, insulin or leptin concentrations although there were correlations between circulating MCH and leptin concentrations in older individuals (P = 0.029). These results indicate that the role of circulating MCH may not be reflective of its regulatory hypothalamic role

    What makes medical students better listeners?

    Get PDF
    Diagnosing heart conditions by auscultation is an important clinical skill commonly learnt by medical students. Clinical proficiency for this skill is in decline [1], and new teaching methods are needed. Successful discrimination of heartbeat sounds is believed to benefit mainly from acoustical training [2]. From recent studies of auditory training [3,4] we hypothesized that semantic representations outside the auditory cortex contribute to diagnostic accuracy in cardiac auscultation. To test this hypothesis, we analysed auditory evoked potentials (AEPs) which were recorded from medical students while they diagnosed quadruplets of heartbeat cycles. The comparison of trials with correct (Hits) versus incorrect diagnosis (Misses) revealed a significant difference in brain activity at 280-310 ms after the onset of the second cycle within the left middle frontal gyrus (MFG) and the right prefrontal cortex. This timing and locus suggest that semantic rather than acoustic representations contribute critically to auscultation skills. Thus, teaching auscultation should emphasize the link between the heartbeat sound and its meaning. Beyond cardiac auscultation, this issue is of interest for all fields where subtle but complex perceptual differences identify items in a well-known semantic context

    Optimal path planning for nonholonomic robotics systems via parametric optimisation

    Get PDF
    Abstract. Motivated by the path planning problem for robotic systems this paper considers nonholonomic path planning on the Euclidean group of motions SE(n) which describes a rigid bodies path in n-dimensional Euclidean space. The problem is formulated as a constrained optimal kinematic control problem where the cost function to be minimised is a quadratic function of translational and angular velocity inputs. An application of the Maximum Principle of optimal control leads to a set of Hamiltonian vector field that define the necessary conditions for optimality and consequently the optimal velocity history of the trajectory. It is illustrated that the systems are always integrable when n = 2 and in some cases when n = 3. However, if they are not integrable in the most general form of the cost function they can be rendered integrable by considering special cases. This implies that it is possible to reduce the kinematic system to a class of curves defined analytically. If the optimal motions can be expressed analytically in closed form then the path planning problem is reduced to one of parameter optimisation where the parameters are optimised to match prescribed boundary conditions.This reduction procedure is illustrated for a simple wheeled robot with a sliding constraint and a conventional slender underwater vehicle whose velocity in the lateral directions are constrained due to viscous damping

    Process mapping of laser surface modification of AISI 316L stainless steel for biomedical applications

    Get PDF
    A 1.5-kW CO2 laser in pulsed mode at 3 kHz was used to investigate the effects of varied laser process parameters and resulting morphology of AISI 316L stainless steel. Irradiance and residence time were varied between 7.9 to 23.6 MW/cm2 and 50 to 167 µs respectively. A strong correlation between irradiance, residence time, depth of processing and roughness of processed steel was established. The high depth of altered microstructure and increased roughness were linked to higher levels of both irradiance and residence times. Energy fluence and surface temperature models were used to predict levels of melting occurring on the surface through the analysis of roughness and depth of the region processed. Microstructural images captured by the SEM revealed significant grain structure changes at higher irradiances, but due to increased residence times, limited to the laser in use, the hardness values were not improved

    Emotional pre-eminence of human vocalizations.

    Get PDF
    Human vocalizations (HV), as well as environmental sounds, convey a wide range of information, including emotional expressions. The latter have been relatively rarely investigated, and, in particular, it is unclear if duration-controlled non-linguistic HV sequences can reliably convey both positive and negative emotional information. The aims of the present psychophysical study were: (i) to generate a battery of duration-controlled and acoustically controlled extreme valence stimuli, and (ii) to compare the emotional impact of HV with that of other environmental sounds. A set of 144 HV and other environmental sounds was selected to cover emotionally positive, negative, and neutral values. Sequences of 2 s duration were rated on Likert scales by 16 listeners along three emotional dimensions (arousal, intensity, and valence) and two non-emotional dimensions (confidence in identifying the sound source and perceived loudness). The 2 s stimuli were reliably perceived as emotionally positive, negative or neutral. We observed a linear relationship between intensity and arousal ratings and a "boomerang-shaped" intensity-valence distribution, as previously reported for longer, duration-variable stimuli. In addition, the emotional intensity ratings for HV were higher than for other environmental sounds, suggesting that HV constitute a characteristic class of emotional auditory stimuli. In addition, emotionally positive HV were more readily identified than other sounds, and emotionally negative stimuli, irrespective of their source, were perceived as louder than their positive and neutral counterparts. In conclusion, HV are a distinct emotional category of environmental sounds and they retain this emotional pre-eminence even when presented for brief periods

    Brain mechanisms for perceiving illusory lines in humans.

    Get PDF
    Illusory contours (ICs) are perceptions of visual borders despite absent contrast gradients. The psychophysical and neurobiological mechanisms of IC processes have been studied across species and diverse brain imaging/mapping techniques. Nonetheless, debate continues regarding whether IC sensitivity results from a (presumably) feedforward process within low-level visual cortices (V1/V2) or instead are processed first within higher-order brain regions, such as lateral occipital cortices (LOC). Studies in animal models, which generally favour a feedforward mechanism within V1/V2, have typically involved stimuli inducing IC lines. By contrast, studies in humans generally favour a mechanism where IC sensitivity is mediated by LOC and have typically involved stimuli inducing IC forms or shapes. Thus, the particular stimulus features used may strongly contribute to the model of IC sensitivity supported. To address this, we recorded visual evoked potentials (VEPs) while presenting human observers with an array of 10 inducers within the central 5°, two of which could be oriented to induce an IC line on a given trial. VEPs were analysed using an electrical neuroimaging framework. Sensitivity to the presence vs. absence of centrally-presented IC lines was first apparent at ∼200 ms post-stimulus onset and was evident as topographic differences across conditions. We also localized these differences to the LOC. The timing and localization of these effects are consistent with a model of IC sensitivity commencing within higher-level visual cortices. We propose that prior observations of effects within lower-tier cortices (V1/V2) are the result of feedback from IC sensitivity that originates instead within higher-tier cortices (LOC)

    The coupling of low-level auditory dysfunction and oxidative stress in psychosis patients.

    Get PDF
    Patients diagnosed with schizophrenia often present with low-level sensory deficits. It is an open question whether there is a functional link between these deficits and the pathophysiology of the disease, e.g. oxidative stress and glutathione (GSH) metabolism dysregulation. Auditory evoked potentials (AEPs) were recorded from 21 psychosis disorder patients and 30 healthy controls performing an active, auditory oddball task. AEPs to standard sounds were analyzed within an electrical neuroimaging framework. A peripheral measure of participants' redox balance, the ratio of glutathione peroxidase and glutathione reductase activities (GPx/GR), was correlated with the AEP data. Patients displayed significantly decreased AEPs over the time window of the P50/N100 complex resulting from significantly weaker responses in the left temporo-parietal lobe. The GPx/GR ratio significantly correlated with patients' brain activity during the time window of the P50/N100 in the medial frontal lobe. We show for the first time a direct coupling between electrophysiological indices of AEPs and peripheral redox dysregulation in psychosis patients. This coupling is limited to stages of auditory processing that are impaired relative to healthy controls and suggests a link between biochemical and sensory dysfunction. The data highlight the potential of low-level sensory processing as a trait-marker of psychosis
    corecore