    Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results

    Get PDF
    We report on the first stages of a clinical study designed to test elastic-scattering spectroscopy, mediated by fiberoptic probes, for three specific clinical applications in breast-tissue diagnosis: (1) a transdermal-needle (interstitial) measurement for instant diagnosis with minimal invasiveness similar to fine-needle aspiration but with sensitivity to a larger tissue volume, (2) a hand-held diagnostic probe for use in assessing tumor/resection margins during open surgery, and (3) use of the same probe for real-time assessment of the `sentinel' node during surgery to determine the presence or absence of tumor (metastatic). Preliminary results from in vivo measurements on 31 women are encouraging. Optical spectra were measured on 72 histology sites in breast tissue, and 54 histology sites in sentinel nodes. Two different artificial intelligence methods of spectral classification were studied. Artificial neural networks yielded sensitivities of 69% and 58%, and specificities of 85% and 93%, for breast tissue and sentinel nodes, respectively. Hierarchical cluster analysis yielded sensitivities of 67% and 91%, and specificities of 79% and 77%, for breast tissue and sentinel nodes, respectively. These values are expected to improve as the data sets continue to grow and more sophisticated data preprocessing is employed. The study will enroll up to 400 patients over the next two years

    Eye movements and hazard perception in active and passive driving

    Get PDF
    Differences in eye movement patterns are often found when comparing passive viewing paradigms to actively engaging in everyday tasks. Arguably, investigations into visuomotor control should therefore be most useful when conducted in settings that incorporate the intrinsic link between vision and action. We present a study that compares oculomotor behaviour and hazard reaction times across a simulated driving task and a comparable, but passive, video-based hazard perception task. We found that participants scanned the road less during the active driving task and fixated closer to the front of the vehicle. Participants were also slower to detect the hazards in the driving task. Our results suggest that the interactivity of simulated driving places increased demand upon the visual and attention systems than simply viewing driving movies. We offer insights into why these differences occur and explore the possible implications of such findings within the wider context of driver training and assessment

    Detection of gastrointestinal cancer by elastic scattering and absorption spectroscopies with the Los Alamos Optical Biopsy System

    Full text link
    The Los Alamos National Laboratory has continued the development of the Optical Biopsy System (OBS) for noninvasive, real-time in situ diagnosis of tissue pathologies. In proceedings of earlier SPIE conferences we reported on clinical measurements in the bladder, and we report here on recent results of clinical tests in the gastrointestinal tract. With the OBS, tissue pathologies are detected/diagnosed using spectral measurements of the elastic optical transport properties (scattering and absorption) of the tissue over a wide range of wavelengths. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, exhibit significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes m an optical signature that is derived from the wavelength-dependence of elastic scattering. Additionally, the optical geometry of the OBS beneficially enhances its sensitivity for measuring absorption bands. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope or catheter, or to direct surface examination, as well as interstitial needle insertion. Data acquistion/display time is <1 second

    Rh discrepancies caused by variable reactivity of partial and weak D types with different serologic techniques

    Full text link
    RhD discrepancies between current and historical results are problematic to resolve. The investigation of 10 discrepancies is reported here. STUDY DESIGN: Samples identified were those that reacted by automated gel technology and were negative with an FDA-approved reagent. Reactivity with a commercially available panel of monoclonal anti-D was performed. Genomic DNA was evaluated for RHD alleles with multiplex RHD exon polymerase chain reaction (PCR), weak D PCR-restriction fragment length polymorphism, and RHD exon 5 and 7 sequence analyses. RESULTS: The monoclonal anti-D panel identified two samples as DVa, yet possessed the DAR allele. Two weak D Type 1 samples had a similar monoclonal anti-D profile, but only one reacted directly with one of two FDA-approved anti-D. Only two of four weak D Type 2 samples reacted directly with one FDA-approved anti-D, and their D epitope profile differed. CONCLUSIONS: The monoclonal anti-D reagents did not distinguish between partial and weak D Types 1 and 2. Weak D Types 1 and 2 do not show consistent reactivity with FDA-approved reagents and technology. To limit anti-D alloimmunization, it is recommended that samples yielding an immediate-spin tube test cutoff score of not more than 5 (i.e., ≤1+ agglutination) or a score of not more than 8 (i.e., ≤2+ hemagglutination) by gel technology be considered D– for transfusion and Rh immune globulin prophylaxis. That tube test anti-D reagents react poorly with some Weak D Types 1 and 2 red cells is problematic, inasmuch as they should be considered D+ for transfusion and prenatal care. Molecular tests that distinguish common partial and Weak D types provide the solution to resolving D antigen discrepancies.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75591/1/j.1537-2995.2007.01551.x.pd

    Using an oblique incident laser beam to measure the optical properties of stomach mucosa/submucosa tissue

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of the study is to determine the optical properties and their differences for normal human stomach mucosa/submucosa tissue in the cardiac orifice <it>in vitro </it>at 635, 730, 808, 890 and 980 nm wavelengths of laser.</p> <p>Methods</p> <p>The measurements were performed using a CCD detector, and the optical properties were assessed from the measurements using the spatially resolved reflectance, and nonlinear fitting of diffusion equation.</p> <p>Results</p> <p>The results of measurement showed that the absorption coefficients, the reduced scattering coefficients, the optical penetration depths, the diffusion coefficients, the diffuse reflectance and the shifts of diffuse reflectance of tissue samples at five different wavelengths vary with a change of wavelength. The maximum absorption coefficient for tissue samples is 0.265 mm<sup>-1 </sup>at 980 nm, and the minimum absorption coefficient is 0.0332 mm<sup>-1 </sup>at 730 nm, and the maximum difference in the absorption coefficients is 698% between 730 and 980 nm, and the minimum difference is 1.61% between 635 and 808 nm. The maximum reduced scattering coefficient for tissue samples is 1.19 mm<sup>-1 </sup>at 635 nm, and the minimum reduced scattering coefficient is 0.521 mm<sup>-1 </sup>at 980 nm, and the maximum difference in the reduced scattering coefficients is 128% between 635 and 980 nm, and the minimum difference is 1.15% between 890 and 980 nm. The maximum optical penetration depth for tissue samples is 3.57 mm at 808 nm, and the minimum optical penetration depth is 1.43 mm at 980 nm. The maximum diffusion constant for tissue samples is 0.608 mm at 890 nm, and the minimum diffusion constant is 0.278 mm at 635 nm. The maximum diffuse reflectance is 3.57 mm<sup>-1 </sup>at 808 nm, and the minimum diffuse reflectance is 1.43 mm<sup>-1 </sup>at 980 nm. The maximum shift Δx of diffuse reflectance is 1.11 mm<sup>-1 </sup>at 890 nm, and the minimum shift Δx of diffuse reflectance is 0.507 mm<sup>-1 </sup>at 635 nm.</p> <p>Conclusion</p> <p>The absorption coefficients, the reduced scattering coefficients, the optical penetration depths, the diffusion coefficients, the diffuse reflectance and the shifts of diffuse reflectance of tissue samples at 635, 730, 808, 890 and 980 nm wavelengths vary with a change of wavelength. There were significant differences in the optical properties for tissue samples at five different wavelengths (<it>P </it>< 0.01).</p

    Frequency and distribution of rare electrophoretic mobility variants in a population of human newborns in Ann Arbor, Michigan

    Full text link
    We have summarized the frequency and distribution of the rare variants encountered during the screening of 258 815 allele products, the products of 51 different loci, in 3242 predominantly Caucasian (88 %) newborns. Seventy-nine different rare variants, representing 187 occurrences, were identified. Almost 60 % (46 of 79) of the rare variants occurred as singletons while another 20 % were seen in two unrelated individuals. No rare variants were detected at 18 loci while no variants, either rare or polymorphic, were detected at 14 loci. More rare variants were identified at loci that were classified as polymorphic and also at loci where the gene products exist as a monomer. A positive relationship was observed between variant frequency, either classes or copies, and subunit molecular mass.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65173/1/j.1469-1809.1987.tb01065.x.pd

    People of the British Isles: preliminary analysis of genotypes and surnames in a UK control population

    Get PDF
    There is a great deal of interest in fine scale population structure in the UK, both as a signature of historical immigration events and because of the effect population structure may have on disease association studies. Although population structure appears to have a minor impact on the current generation of genome-wide association studies, it is likely to play a significant part in the next generation of studies designed to search for rare variants. A powerful way of detecting such structure is to control and document carefully the provenance of the samples involved. Here we describe the collection of a cohort of rural UK samples (The People of the British Isles), aimed at providing a well-characterised UK control population that can be used as a resource by the research community as well as providing fine scale genetic information on the British population. So far, some 4,000 samples have been collected, the majority of which fit the criteria of coming from a rural area and having all four grandparents from approximately the same area. Analysis of the first 3,865 samples that have been geocoded indicates that 75% have a mean distance between grandparental places of birth of 37.3km, and that about 70% of grandparental places of birth can be classed as rural. Preliminary genotyping of 1,057 samples demonstrates the value of these samples for investigating fine scale population structure within the UK, and shows how this can be enhanced by the use of surnames
    • …