552 research outputs found

    Memory Function versus Binary Correlator in Additive Markov Chains

    Full text link
    We study properties of the additive binary Markov chain with short and long-range correlations. A new approach is suggested that allows one to express global statistical properties of a binary chain in terms of the so-called memory function. The latter is directly connected with the pair correlator of a chain via the integral equation that is analyzed in great detail. To elucidate the relation between the memory function and pair correlator, some specific cases were considered that may have important applications in different fields.Comment: 31 pages, 1 figur

    The Influence of Annealing Thermal on the Properties of Au:TiO2 Nanocomposite Film

    Get PDF
    Two sets of nanocomposite films consisting of different atomic concentrations of Au dispersed in a TiO2 dielectric matrix were deposited by DC reactive magnetron sputtering, and subjected to several annealing trataments in vacuum, for temperatures ranging from 300 to 800 0C. The obtained results show that the structure and the size of Au clusters, together with the matrix crystallinity, changed as a result of the annealing As a result of these structural variations the film optical properties were modified too. The optical changes, and the correspondent Surface Plasmon Resonance effect were confirmed by reflectivity and CIELab colour measurements. XRD analysis confirmed the presence of gold in all the samples, and the crystallization of the TiO2 matrix for the samples annealed at temperatures above 4000C. With further increase of the annealing temperature, there is a change from the TiO2 anatase phase into rutile-type structure. Simultaneously, the Au atoms are organized in crystalline nanoparticles (revealing an fcc-type structure, with the (111) preferential growth orientation). When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/3491

    Influence Of A Cobalt-chromium Metal Framework On Surface Roughness And Knoop Hardness Of Visible Light-polymerized Acrylic Resins

    Get PDF
    Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-μm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm 2) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 μm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p<0.05) for roughness and Knoop hardness, with light-polymerized resin presenting the highest values (Ra = 0.11 μm and hardness between 20.2 and 21.4 Kg/mm 2). Knoop values at different distances from the metal bar did not differ statistically (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.143208212Anusavice, K.J., (2003) Philip's Science of Dental Materials. 11 th Ed., p. 96. , 11 St. Louis: Elsevier ScienceBollen, C.M.L., Lambrechts, P., Quirynen, M., Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature (1997) Dent Mater, 13 (4), pp. 258-269Borchers, L., Tavassol, F., Tschernitschek, H., Surface quality achieved by polishing and by varnishing of temporary crown and fixed partial denture resins (1999) J Prosthet Dent, 82 (5), pp. 550-556Braun, K.O., Del Bel Cury, A.A., Cury, J.A., Use of microwave energy for processing acrylic resin near metal (1998) Braz Oral Res, 12 (2), pp. 173-180Curtis, D.A., Eggleston, T.L., Marshall, S.J., Watanabe, L.G., Shear bond strength of visible-light-cured resin relative to heat-cured resin (1989) Dental Mater, 5 (7), pp. 314-318De Clerck, J.P., Microwave polymerization of acrylic resins used in dental prosthesis (1987) J Prosthet Dent, 57 (5), pp. 650-658Khan, Z., Von Fraunhofer, J.A., Razavi, R., The staining characteristics, transverse strength, and microhardness of a visible light-cured denture base material (1987) J Prosthet Dent, 57 (3), pp. 384-386Levin, B., Sanders, J.L., Reitz, P.V., The use of microwave energy for processing acrylic resins (1989) J Prosthet Dent, 61 (3), pp. 381-383Ogle, R.E., Sorensen, S.E., Lewis, E.A., A new visible light-cured resin system applied to removable prosthodontics (1986) J Prosthet Dent, 56 (4), pp. 497-506Quirynen, M., Cml, B., Willems, G., Van Steenberghe, D., Comparison of surface characteristics of six commercially pure titanium abutments (1994) JOMI, 9 (1), pp. 71-76Reitz, P.V., Sanders, J.L., Levin, B., The curing of denture acrylic resins by microwave energy. Physical properties (1985) Quintessence Int, 6 (8), pp. 547-551Rodrigues Garcia, R.C.M., Souza Jr., J.A., Rached, R.N., Del Bel Cury, A.A., Effect of denture cleansers on the surface roughness and hardness of a microwave-cured acrylic resin and dental alloys (2004) J Prosthodont, 13 (3), pp. 1-6Rueggeberg, F.A., Goughman, W.F., Curtis Jr., J.W., Effect of light intensity and exposure duration on cure of resin composite (1994) Oper Dent, 19 (1), pp. 26-32Truong, V.T., Thomasz, F.G., Comparison of denture acrylic resins cured by boiling water and microwave energy (1988) Aust Dent J, 33 (3), pp. 201-204Ulusoy, M., Ulusoy, N., Aydin, A.K., An evaluation of polishing technique on surface roughness of acrylic rsins (1986) J Prosthetic Dent, 56 (1), pp. 107-11

    Comparation Between Pulsed Nd: Yag Laser Superficial Treatment and Ceramic Coating in Creep Test of Ti-6aAl-4V Alloy

    Get PDF
    The objective of this work was evaluating the creep resistance of the Ti-6Al-4V alloy with superficial treatment of pulsed Nd:YAG laser and ceramic coating in creep test of Ti-6Al-4V alloy. It was used Ti-6Al-4V alloy as cylindrical bars under forged and annealing of 190oC by 6 hours condition and cooled by air. The Ti-6Al-4V alloy after the superficial treatment of pulsed Nd:YAG laser and ceramic coating was submitted to creep tests at 600°C and 125 at 319 MPa, under constant load mode. In the Nd:YAG pulsed laser treatment was used an environment of 40 % N and 60 % Ar, with 2.1 W of power and 10 m/s of speed. Yttria (8 wt.%) stabilized zirconia (YSZ) with a CoNiCrAlY bond coat was atmospherically plasma sprayed on Ti-6Al-4V substrates by Sulzer Metco Type 9 MB. The obtained results suggest the laser treatment on Ti-6Al-4V alloy improved its creep resistance

    Membrane-associated proteins of ejaculated sperm from Morada Nova rams

    Get PDF
    AbstractThe objective was to describe the profile of membrane proteins from sperm of tropically adapted Morada Nova rams (N = 5). Samples from protein-enriched fractions of ejaculated sperm (containing 400 μg of protein) were separated by two-dimensional electrophoresis and respective maps analyzed using PDQuest software (version 7.3.0; Bio-Rad). Proteins were identified using tandem mass spectrometry. Also, membrane proteins were incubated with antibodies against binder of sperm protein (BSP) 1 and bodhesin 2 (Bdh-2), components of vesicular gland secretion. For membrane proteins of ejaculated sperm, an average of 133 ± 4.6 spots were detected per gel, of which, 107 spots were consistently present on all gels. Sixty-eight spots and 37 proteins were identified using mass spectrometry, corresponding to 71.6% of the intensity of all spots detected. Three major spots identified as ram seminal vesicle protein (RSVP) 14 represented approximately 30% of the intensity of all spots. Two of the most intense spots in the gel reacted against anti-BSP1, at 14 kDa. In addition, four low molecular weight spots reacted with anti-Bdh-2 antibodies. Proteins RSVP and Bdh-2 belong to the BSP and spermadhesin families, respectively, and were previously reported as major components of ram seminal proteins. Additional proteins identified in the sperm membrane two-dimensional maps included alpha-2-heparan sulfate-glycoprotein, plasma glutamate carboxypeptidase, arylsulfatase A, cathelicidin, heat shock protein 70 kDa, angiotensin-converting enzyme, leucine aminopeptidase, and clusterin. Some proteins were present as multiple isoforms, such as tubulin (12), alpha-2-heparan sulfate-glycoprotein (5), ATP synthase (5), Bdh-2 (4) and RSVP14 (3). Based on gene ontology analysis, the most common biological processes associated with the membrane proteins were cellular processes (34%), response to stimulus (14%), and metabolic processes (11%). Binding (37%) and catalytic activity (32%) corresponded to the most frequent molecular functions for those proteins. In conclusion, we identified a diverse cohort of components of membrane proteins in ram sperm. Major proteins previously reported in seminal plasma, such as RSVP14 and Bdh-2, were also extracted from sperm membranes. Knowledge of sperm proteins is crucial for elucidating mechanisms underlying their association with sperm function

    Classical Solutions in a Lorentz-violating Maxwell-Chern-Simons Electrodynamics

    Full text link
    We take as starting point the planar model arising from the dimensional reduction of the Maxwell Electrodynamics with the (Lorentz-violating) Carroll-Field-Jackiw term. We then write and study the extended Maxwell equations and the corresponding wave equations for the potentials. The solution to these equations show some interesting deviations from the usual MCS Electrodynamics, with background-dependent correction terms. In the case of a time-like background, the correction terms dominate over the MCS sector in the region far from the origin, and establish the behaviour of a massless Electrodynamics (in the electric sector). In the space-like case, the solutions indicate the clear manifestation of spatial anisotropy, which is consistent with the existence of a privileged direction is space.Comment: latex, 8 page

    Signatures of small-world and scale-free properties in large computer programs

    Full text link
    A large computer program is typically divided into many hundreds or even thousands of smaller units, whose logical connections define a network in a natural way. This network reflects the internal structure of the program, and defines the ``information flow'' within the program. We show that, (1) due to its growth in time this network displays a scale-free feature in that the probability of the number of links at a node obeys a power-law distribution, and (2) as a result of performance optimization of the program the network has a small-world structure. We believe that these features are generic for large computer programs. Our work extends the previous studies on growing networks, which have mostly been for physical networks, to the domain of computer software.Comment: 4 pages, 1 figure, to appear in Phys. Rev.

    Seminal plasma proteins and their relationship with percentage of morphologically normal sperm in 2-year-old Brahman (Bos indicus) bulls

    Get PDF
    The objective was to determine the relationship between seminal plasma proteins and sperm morphology in Bos indicus bulls of the Brahman breed. Fifty-six 24-month-old Australian Brahman bulls were electroejaculated and samples were examined to determine the percentage of morphologically normal sperm (PNS24) and the seminal plasma protein composition was identified and quantified by 2-D gel electrophoresis. The total integrated optical density of 152 seminal plasma protein spots (SPPs) across all gels was determined using the PDQuest software version 8.0 (Bio Rad, USA). Using a single regression mixed model with the density of individual spots as a covariate for PNS24, 17 SPPs were significantly associated with PNS24 (
    corecore