    How to diagnose acute appendicitis: ultrasound first

    Get PDF
    International audienceAcute appendicitis (AA) is a common abdominal emergency with a lifetime prevalence of about 7 %. As the clinical diagnosis of AA remains a challenge to emergency physicians and surgeons, imaging modalities have gained major importance in the diagnostic work-up of patients with suspected AA in order to keep both the negative appendectomy rate and the perforation rate low. Introduced in 1986, graded-compression ultrasound (US) has well-established direct and indirect signs for diagnosing AA. In our opinion, US should be the first-line imaging modality, as graded-compression US has excellent specificity both in the paediatric and adult patient populations. As US sensitivity is limited, and non-diagnostic US examinations with non-visualization of the appendix are more a rule than an exception, diagnostic strategies and algorithms after non-diagnostic US should focus on clinical reassessment and complementary imaging with MRI/CT if indicated. Accordingly, both ionizing radiation to our patients and cost of pre-therapeutic diagnosis of AA will be low, with low negative appendectomy and perforation rates

    Imaging patients with renal colic\ue2\u80\u94consider ultrasound first

    No full text
    Abstract: Renal colic is a common disease in Europe and a common cause of visit to the Emergency Department. Clinical diagnosis is usually confirmed by imaging modalities. Unenhanced computed tomography (CT) is considered the best diagnostic test due to its excellent accuracy detecting ureteral stones. However, ultrasound (US) should be considered as the primary imaging technique. It is a reproducible, non-invasive and non-expensive imaging technique, achieving accurate diagnosis in most cases without the need for radiation. Diagnosis is based on the presence of ureteral stones, but indirect findings such as the asymmetry or absence of ureteric jet, an increase of the resistive index or a colour Doppler twinkling artefact may help to suggest the diagnosis when the stone is not identified. Main Messages: \ue2\u80\ua2 Renal colic diagnosis is usually confirmed by imaging modalities. \ue2\u80\ua2 Imaging diagnosis of renal colic is based on the detection of ureteral stones. \ue2\u80\ua2 CT is the most accurate imaging technique to identify ureteral stones. \ue2\u80\ua2 US allows correct diagnosis in most cases without using radiation. \ue2\u80\ua2 US should be used as the first imaging modality in patients with renal colic

    Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group

    No full text
    Abstract Objectives The objective of these recommendations is to highlight the importance of infection prevention and control in ultrasound (US), including diagnostic and interventional settings. Methods Review of available publications and discussion within a multidisciplinary group consistent of radiologists and microbiologists, in consultation with European patient and industry representatives. Recommendations Good basic hygiene standards are essential. All US equipment must be approved prior to first use, including hand held devices. Any equipment in direct patient contact must be cleaned and disinfected prior to first use and after every examination. Regular deep cleaning of the entire US machine and environment should be undertaken. Faulty transducers should not be used. As outlined in presented flowcharts, low level disinfection is sufficient for standard US on intact skin. For all other minor and major interventional procedures as well as all endo-cavity US, high level disinfection is mandatory. Dedicated transducer covers must be used when transducers are in contact with mucous membranes or body fluids and sterile gel should be used inside and outside covers. Conclusions Good standards of basic hygiene and thorough decontamination of all US equipment as well as appropriate use of US gel and transducer covers are essential to keep patients safe. Main messages • Transducers must be cleaned/disinfected before first use and after every examination. • Low level disinfection is sufficient for standard US on intact skin. • High level disinfection is mandatory for endo-cavity US and all interventions. • Dedicated transducer covers must be used for endo-cavity US and all interventions. • Sterile gel should be used for all endo-cavity US and all interventions
    corecore