22 research outputs found

    Cancer risks following diagnostic and therapeutic radiation exposure in children

    Get PDF
    The growing use of interventional and fluoroscopic imaging in children represents a tremendous benefit for the diagnosis and treatment of benign conditions. Along with the increasing use and complexity of these procedures comes concern about the cancer risk associated with ionizing radiation exposure to children. Children are considerably more sensitive to the carcinogenic effects of ionizing radiation than adults, and children have a longer life expectancy in which to express risk. Numerous epidemiologic cohort studies of childhood exposure to radiation for treatment of benign diseases have demonstrated radiation-related risks of cancer of the thyroid, breast, brain and skin, as well as leukemia. Many fewer studies have evaluated cancer risk following diagnostic radiation exposure in children. Although radiation dose for a single procedure might be low, pediatric patients often receive repeated examinations over time to evaluate their conditions, which could result in relatively high cumulative doses. Several cohort studies of girls and young women subjected to multiple diagnostic radiation exposures have been informative about increased mortality from breast cancer with increasing radiation dose, and case-control studies of childhood leukemia and postnatal diagnostic radiation exposure have suggested increased risks with an increasing number of examinations. Only two long-term follow-up studies of cancer following cardiac catheterization in childhood have been conducted, and neither reported an overall increased risk of cancer. Most cancers can be induced by radiation, and a linear dose-response has been noted for most solid cancers. Risks of radiation-related cancer are greatest for those exposed early in life, and these risks appear to persist throughout life

    Guidelines on "Standards of management of idiopathic scoliosis with corrective braces in everyday clinics and in clinical research": SOSORT Consensus 2008

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reported failure rates,(defined based on percentage of cases progressing to surgery) of corrective bracing for idiopathic scoliosis are highly variable. This may be due to the quality of the brace itself, but also of the patient care during treatment. The latter is sometimes neglected, even though it is considered a main determinant of good results among conservative experts of SOSORT. The aim of this paper was to develop and verify the Consensus on management of scoliosis patients treated with braces</p> <p>Methods</p> <p>We followed a Delphi process in four steps, distributing and gradually changing according to the results a set of recommendations: we involved the SOSORT Board twice, then all SOSORT members twice, with a Pre-Meeting Questionnaire (PMQ), and during a Consensus Session at the SOSORT Athens Meeting with a Meeting Questionnaire (MQ). We set a 90% agreement as the minimum to be reached.</p> <p>Results</p> <p>We had a 71% response rate to PMQ, and 66.7% to MQ. Since the PMQ we had a good agreement (no answers below 72% – 70.2% over 90%). With the MQ the agreement consistently increased for all the answers previously below 90% (no answers below 83%, 75% over 90%). With increasing experience in bracing all numerical criteria tended to become more strict. We finally produced a set of 14 recommendations, grouped in 6 Domains (Experience/competence, Behaviours, Prescription, Construction, Brace Check, Follow-up).</p> <p>Conclusion</p> <p>The Consensus permits establishment of recommendations concerning the standards of management of idiopathic scoliosis with bracing, with the aim to increase efficacy and compliance to treatment. The SOSORT recommends to professionals engaged in patient care to follow the guidelines of this Consensus in their clinical practice. The SOSORT criteria should also be followed in clinical research studies to achieve a minimum quality of care. If the aim is to verify the efficacy of bracing these criteria should be companions of the methodological research criteria for bracing proposed by other societies.</p

    Interventional radiography and mortality risks in U.S. radiologic technologists

    Get PDF
    With the exponential increase in minimally invasive fluoroscopically guided interventional radiologic procedures, concern has increased about the health effects on staff and patients of radiation exposure from these procedures. There has been no systematic epidemiologic investigation to quantify serious disease risks or mortality. To quantify all-cause, circulatory system disease and cancer mortality risks in U.S. radiologic technologists who work with interventional radiographic procedures, we evaluated mortality risks in a nationwide cohort of 88,766 U.S. radiologic technologists (77% female) who completed a self-administered questionnaire during 1994–998 and were followed through 31 December 2003. We obtained information on work experience, types of procedures (including fluoroscopically guided interventional procedures), and protective measures plus medical, family cancer history, lifestyle, and reproductive information. Cox proportional hazards regression models were used to compute relative risks (RRs) with 95% confidence intervals (CIs). Between completion of the questionnaire and the end of follow-up, there were 3,581 deaths, including 1,209 from malignancies and 979 from circulatory system diseases. Compared to radiologic technologists who never or rarely performed or assisted with fluoroscopically guided interventional procedures, all-cause mortality risks were not increased among those working on such procedures daily. Similarly, there was no increased risk of mortality resulting from all circulatory system diseases combined, all cancers combined, or female breast cancer among technologists who daily performed or assisted with fluoroscopically guided interventional procedures. Based on small numbers of deaths (n=151), there were non-significant excesses (40%–0%) in mortality from cerebrovascular disease among technologists ever working with these procedures. The absence of significantly elevated mortality risks in radiologic technologists reporting the highest frequency of interventional radiography procedures must be interpreted cautiously in light of the small number of deaths during the relatively short follow-up. The present study cannot rule out increased risks of cerebrovascular disease, specific cancers, and diseases with low case-fatality rates or a long latency period preceding death

    Identification of women with an increased risk of developing radiation-induced breast cancer: a case only study

    Get PDF
    Introduction: Radiation exposure at a young age is one of the strongest risk factors for breast cancer. Germline mutations in genes involved in the DNA-damage repair pathway (DDRP) may render women more susceptible to radiation-induced breast cancer. Methods: We evaluated the contribution of germline mutations in the DDRP genes BRCA1, BRCA2, CHEK2 and ATM to the risk of radiation-induced contralateral breast cancer (CBC). The germline mutation frequency was assessed, in a case-only study, in women who developed a CBC after they had a first breast cancer diagnosed before the age of 50 years, and who were (n = 169) or were not (n = 78) treated with radiotherapy for their first breast tumour. Results: We identified 27 BRCA1, 5 BRCA2, 15 CHEK2 and 4 truncating ATM germline mutation carriers among all CBC patients tested (21%). The mutation frequency was 24.3% among CBC patients with a history of radiotherapy, and 12.8% among patients not irradiated for the first breast tumour (odds ratio 2.18 (95% confidence interval 1.03 to 4.62); p = 0.043). The association between DDRP germline mutation carriers and risk of radiation-induced CBC seemed to be strongest in women who developed their second primary breast tumour at least 5 years after radiotherapy. Th

    A new system for measuring three-dimensional back shape in scoliosis

    No full text
    The aim of this work was to develop a low-cost automated system to measure the three-dimensional shape of the back in patients with scoliosis. The resulting system uses structured light to illuminate a patient’s back from an angle while a digital photograph is taken. The height of the surface is calculated using Fourier transform profilometry with an accuracy of Β±1Β mm. The surface is related to body axes using bony landmarks on the back that have been palpated and marked with small coloured stickers prior to photographing. Clinical parameters are calculated automatically and presented to the user on a monitor and as a printed report. All data are stored in a database. The database can be interrogated and successive measurements plotted for monitoring the deformity changes. The system developed uses inexpensive hardware and open source software. Accurate surface topography can help the clinician to measure spinal deformity at baseline and monitor changes over time. It can help the patients and their families to assess deformity. Above all it reduces the dependence on serial radiography and reduces radiation exposure when monitoring spinal deformity

    The rasterstereographic–dynamic analysis of posture in adolescents using a modified Matthiass test

    No full text
    The Matthiass posture test is a clinical test to detect posture changes in children and adolescents. Aim of this study was to objectify this test using a dynamic rasterstereographic measuring device. We examined 31 healthy athletes during a modified Matthiass test with a dynamic rasterstereographic measuring system. Hereby the trunk inclination, kyphosis and lordosis angle were measured. The trunk inclination decreased by about 50% of the basic value just by raising the arms. Additional weight loads of only 5% body weight (bw) resulted in significant changes of the posture (lordosis and kyphosis angle) during this test. With this rasterstereographic measuring device it seems to be possible to determine spinal posture changes under dynamic conditions. The results suggest that additional weights of 5% bw during the Matthias-test are enough to create significant deviations in posture parameters, even in healthy subjects
    corecore