114 research outputs found

    Piercing the Religious Veil of the So-Called Cults

    Get PDF

    Prospectus, January 21, 2004

    Get PDF
    https://spark.parkland.edu/prospectus_2004/1000/thumbnail.jp

    Appalachian Transition: A cross sector approach to regional transition.

    Get PDF
    Appalachia is made up of many mountains, many communities and many different sectors of work. The Appalachian Transition Fellows based out of the Highlander Education Center have spent 9 months working throughout central Appalachia to build cross sector bridges and to help further a positive growth in the region’s economy. Through the fellowship people are working with different models of transition, including value chains, worker owner cooperatives, local food initiatives, policy making, etc. In this session we will be breaking out into different groups each led by one or two fellows to talk about various ways these different models could be beneficial in different communities in Appalachia. There is value in working not only across county and state lines, but also working across economic sector boundaries. This is a workshop to understand the different models being used and to further discuss how to growth between these models for a more diverse and stronger Appalachian economy

    Inter-calibration of a proposed new primary reference standard AA-ETH Zn for zinc isotopic analysis

    Get PDF
    We have prepared a large volume of pure, concentrated and homogenous zinc standard solution. This new standard solution is intended to be used as a primary reference standard for the zinc isotope community, and to serve as a replacement for the near-exhausted current reference standard, the so-called JMC-Lyon Zn. The isotopic composition of this new zinc standard (AA-ETH Zn) has been determined through an inter-laboratory calibration exercise, calibrated against the existing JMC-Lyon standard, as well as the certified Zn reference standard IRMM-3702. The data show that the new standard is isotopically indistinguishable from the IRMM-3702 zinc standard, with a weighted d66/64Zn value of 0.28±0.02‰ relative to JMC-Lyon. We suggest that this new standard be assigned a value d66/64Zn of +0.28‰ for reporting of future Zn isotope data, with the rationale that all existing published Zn isotope data are presented relative to the JMC-Lyon standard. Therefore our proposed presentation allows a direct comparison with all previously published data, and that is directly traceable to a certified reference standard, IRMM-3702 Zn. This standard will be made freely available to all interested labs through contact with the corresponding author

    Prostate MR image quality of apparent diffusion coefficient maps versus fractional intracellular volume maps from VERDICT MRI using the PI-QUAL score and a dedicated Likert scale for artefacts

    Get PDF
    PURPOSE: This study aimed to assess the image quality of apparent diffusion coefficient (ADC) maps derived from conventional diffusion-weighted MRI and fractional intracellular volume maps (FIC) from VERDICT MRI (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) in patients from the INNOVATE trial. The inter-reader agreement was also assessed. METHODS: Two readers analysed both ADC and FIC maps from 57 patients enrolled in the INNOVATE prospective trial. Image quality was assessed using the Prostate Imaging Quality (PI-QUAL) score and a subjective image quality Likert score (Likert-IQ). The image quality of FIC and ADC were compared using a Wilcoxon Signed Ranks test. The inter-reader agreement was assessed with Cohen's kappa. RESULTS: There was no statistically significant difference between the PI-QUAL score for FIC datasets compared to ADC datasets for either reader (p = 0.240 and p = 0.614). Using the Likert-IQ score, FIC image quality was higher compared to ADC (p = 0.021) as assessed by reader-1 but not for reader-2 (p = 0.663). The inter-reader agreement was 'fair' for PI-QUAL scoring of datasets with FIC maps at 0.27 (95% confidence interval; 0.08-0.46) and ADC datasets at 0.39 (95% confidence interval 0.22-0.57). For Likert scoring, the inter-reader agreement was also 'fair' for FIC maps at 0.38 (95% confidence interval; 0.10-0.65) and substantial for ADC maps at 0.62 (95% confidence interval; 0.39-0.86). CONCLUSION: Image quality was comparable for FIC and ADC. The inter-reader agreement was similar when using PIQUAL for both FIC and ADC datasets but higher for ADC maps compared to FIC maps using the image quality Likert score

    Histo-MRI map study protocol: a prospective cohort study mapping MRI to histology for biomarker validation and prediction of prostate cancer

    Get PDF
    INTRODUCTION: Multiparametric MRI (mpMRI) is now widely used to risk stratify men with a suspicion of prostate cancer and identify suspicious regions for biopsy. However, the technique has modest specificity and a high false-positive rate, especially in men with mpMRI scored as indeterminate (3/5) or likely (4/5) to have clinically significant cancer (csPCa) (Gleason ≥3+4). Advanced MRI techniques have emerged which seek to improve this characterisation and could predict biopsy results non-invasively. Before these techniques are translated clinically, robust histological and clinical validation is required. METHODS AND ANALYSIS: This study aims to clinically validate two advanced MRI techniques in a prospectively recruited cohort of men suspected of prostate cancer. Histological analysis of men undergoing biopsy or prostatectomy will be used for biological validation of biomarkers derived from Vascular and Extracellular Restricted Diffusion for Cytometry in Tumours and Luminal Water imaging. In particular, prostatectomy specimens will be processed using three-dimension printed patient-specific moulds to allow for accurate MRI and histology mapping. The index tests will be compared with the histological reference standard to derive false positive rate and true positive rate for men with mpMRI scores which are indeterminate (3/5) or likely (4/5) to have clinically significant prostate cancer (csPCa). Histopathological validation from both biopsy and prostatectomy samples will provide the best ground truth in validating promising MRI techniques which could predict biopsy results and help avoid unnecessary biopsies in men suspected of prostate cancer. ETHICS AND DISSEMINATION: Ethical approval was granted by the London-Queen Square Research Ethics Committee (19/LO/1803) on 23 January 2020. Results from the study will be presented at conferences and submitted to peer-reviewed journals for publication. Results will also be available on ClinicalTrials.gov. TRIAL REGISTRATION NUMBER: NCT04792138

    Mixed Chamber Ensembles

    Get PDF
    Kennesaw State University School of Music presents Mixed Chamber Ensembles, 4:00 performance.https://digitalcommons.kennesaw.edu/musicprograms/1428/thumbnail.jp

    Magnetic Resonance Imaging and targeted biopsies compared to transperineal mapping biopsies prior to salvage focal therapy/ablation in localised and metastatic recurrent prostate cancer after radiotherapy. Primary Outcomes from the FORECAST Trial

    Get PDF
    BACKGROUND: Recurrent prostate cancer after radiotherapy occurs in one in five patients. The efficacy of prostate magnetic resonance imaging (MRI) in recurrent cancer has not been established. Furthermore, high-quality data on new minimally invasive salvage focal ablative treatments are needed. OBJECTIVE: To evaluate the role of prostate MRI in detection of prostate cancer recurring after radiotherapy and the role of salvage focal ablation in treating recurrent disease. DESIGN, SETTING, AND PARTICIPANTS: The FORECAST trial was both a paired-cohort diagnostic study evaluating prostate multiparametric MRI (mpMRI) and MRI-targeted biopsies in the detection of recurrent cancer and a cohort study evaluating focal ablation at six UK centres. A total of 181 patients were recruited, with 155 included in the MRI analysis and 93 in the focal ablation analysis. INTERVENTION: Patients underwent choline positron emission tomography/computed tomography and a bone scan, followed by prostate mpMRI and MRI-targeted and transperineal template-mapping (TTPM) biopsies. MRI was reported blind to other tests. Those eligible underwent subsequent focal ablation. An amendment in December 2014 permitted focal ablation in patients with metastases. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Primary outcomes were the sensitivity of MRI and MRI-targeted biopsies for cancer detection, and urinary incontinence after focal ablation. A key secondary outcome was progression-free survival (PFS). RESULTS AND LIMITATIONS: Staging whole-body imaging revealed localised cancer in 128 patients (71%), with involvement of pelvic nodes only in 13 (7%) and metastases in 38 (21%). The sensitivity of MRI-targeted biopsy was 92% (95% confidence interval [CI] 83-97%). The specificity and positive and negative predictive values were 75% (95% CI 45-92%), 94% (95% CI 86-98%), and 65% (95% CI 38-86%), respectively. Four cancer (6%) were missed by TTPM biopsy and six (8%) were missed by MRI-targeted biopsy. The overall MRI sensitivity for detection of any cancer was 94% (95% CI 88-98%). The specificity and positive and negative predictive values were 18% (95% CI 7-35%), 80% (95% CI 73-87%), and 46% (95% CI 19-75%), respectively. Among 93 patients undergoing focal ablation, urinary incontinence occurred in 15 (16%) and five (5%) had a grade ≥3 adverse event, with no rectal injuries. Median follow-up was 27 mo (interquartile range 18-36); overall PFS was 66% (interquartile range 54-75%) at 24 mo. CONCLUSIONS: Patients should undergo prostate MRI with both systematic and targeted biopsies to optimise cancer detection. Focal ablation for areas of intraprostatic recurrence preserves continence in the majority, with good early cancer control. PATIENT SUMMARY: We investigated the role of magnetic resonance imaging (MRI) scans of the prostate and MRI-targeted biopsies in outcomes after cancer-targeted high-intensity ultrasound or cryotherapy in patients with recurrent cancer after radiotherapy. Our findings show that these patients should undergo prostate MRI with both systematic and targeted biopsies and then ablative treatment focused on areas of recurrent cancer to preserve their quality of life. This trial is registered at ClinicalTrials.gov as NCT01883128

    The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe

    Get PDF
    The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed plan for a world-class experiment dedicated to addressing these questions. LBNE is conceived around three central components: (1) a new, high-intensity neutrino source generated from a megawatt-class proton accelerator at Fermi National Accelerator Laboratory, (2) a near neutrino detector just downstream of the source, and (3) a massive liquid argon time-projection chamber deployed as a far detector deep underground at the Sanford Underground Research Facility. This facility, located at the site of the former Homestake Mine in Lead, South Dakota, is approximately 1,300 km from the neutrino source at Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino charge-parity symmetry violation and mass ordering effects. This ambitious yet cost-effective design incorporates scalability and flexibility and can accommodate a variety of upgrades and contributions. With its exceptional combination of experimental configuration, technical capabilities, and potential for transformative discoveries, LBNE promises to be a vital facility for the field of particle physics worldwide, providing physicists from around the globe with opportunities to collaborate in a twenty to thirty year program of exciting science. In this document we provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess.Comment: Major update of previous version. This is the reference document for LBNE science program and current status. Chapters 1, 3, and 9 provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess. 288 pages, 116 figure
    • …
    corecore