345 research outputs found

    The risks of defensive (emergency) medicine. The laboratory perspective

    Get PDF
    Diagnostic testing is a crucial aspect of the clinical decision making, especially in emergency settings where timely and accurate diagnoses are essential for appropriate patient management. Reliable statistics attest that the vast majority of clinical decisions for diagnosis, treatment and follow-up of both acute and chronic diseases are influenced by results of laboratory analyses. As specifically concerns the emergency department, many unnecessary laboratory tests are also ordered in this healthcare setting, with unfavorable consequences on laboratory and healthcare organization. As far as the laboratory environment is concerned, defensive (emergency medicine) may be associated with incremental costs, derangement of laboratory organization, enhanced complexity of data management process, diagnostic delay attributable to performance of unnecessary testing, and litigation. Educative or even regulatory interventions are hence urgently needed to addresses problems of the current liability system, in order to decrease the detrimental effects of defensive (emergency) medicine in the laboratory

    Relationship between ABO blood group and von Willebrand factor levels: from biology to clinical implications

    Get PDF
    Although a number of studies have demonstrated the influence of ABO blood group on plasma levels of von Willebrand factor (VWF), the nature of this association and its clinical importance is still largely unknown

    Comparison of platelet function between sedentary individuals and competitive athletes at rest

    Get PDF
    BACKGROUND: There are controversial evidences on the effect of different types and workloads of physical exercise on primary hemostasis. In particular, little is known on the chronic influence of a strenuous and regular aerobic training regimen on platelet function. METHODS: The aim of this investigation was to compare platelet function between sedentary controls and trained athletes at rest and to evaluate whether a greater amount of exercise performed in professional cyclists may contribute to increased platelet chronic responsiveness compared to both elite cyclists and sedentary individuals. Platelet's ability to adhere and aggregate was assayed following a 12–24 h resting period in 49 active professional male road cyclists, 40 elite male cyclists and 43 matched sedentary healthy male volunteers, by the platelet function analyzer 100 (PFA-100). RESULTS AND DISCUSSION: Mean values of the collagen-epinephrine test did not differ between controls and athletes (sedentary controls: 111 ± 33 s; elite athletes: 113 ± 26 s, p = 0.93; professional athletes: 120 ± 33 s; p = 0.33), whereas mean values of the collagen-ADP test displayed a slightly but significant trend towards decreased values when comparing sedentary controls (83 ± 21 s) with either elite (77 ± 11 s, p < 0.01) or professional (75 ± 16 s, p < 0.01) athletes. CONCLUSION: The trend towards slightly lower collagen-ADP values are suggestive for a modest but significant chronic activation of primary hemostasis, highlighting the need to set appropriate reference ranges for the PFA-100 when evaluating primary hemostasis in physically active subjects

    Plasma D-dimer concentration in patients with systemic sclerosis

    Get PDF
    BACKGROUND: Systemic sclerosis (SSc) is an autoimmune disorder of the connective tissue characterized by widespread vascular lesions and fibrosis. Little is known so far on the activation of the hemostatic and fibrinolytic systems in SSc, and most preliminary evidences are discordant. METHODS: To verify whether SSc patients might display a prothrombotic condition, plasma D-dimer was assessed in 28 consecutive SSc patients and in 33 control subjects, matched for age, sex and environmental habit. RESULTS AND DISCUSSION: When compared to healthy controls, geometric mean and 95% confidence interval (IC95%) of plasma D-dimer were significantly increased in SSc patients (362 ng/mL, IC 95%: 361–363 ng/mL vs 229 ng/mL, IC95%: 228–231 ng/mL, p = 0.005). After stratifying SSc patients according to disease subset, no significant differences were observed between those with limited cutaneous pattern and controls, whereas patients with diffuse cutaneous pattern displayed substantially increased values. No correlation was found between plasma D-dimer concentration and age, sex, autoantibody pattern, serum creatinine, erythrosedimentation rate, nailfold videocapillaroscopic pattern and pulmonary involvement. CONCLUSION: We demonstrated that SSc patients with diffuse subset are characterized by increased plasma D-dimer values, reflecting a potential activation of both the hemostatic and fibrinolytic cascades, which might finally predispose these patients to thrombotic complications

    Non-commutability of results of highly sensitive troponin I and T immunoassays

    Get PDF
    Introduction: The measurement of cardiospecific troponins is pivotal in the diagnostic and prognostic approach of patients with suspected acute myocardial infarction (AMI). However, no information is available on the commutability of results between the novel highly-sensitive (HS) troponin T (TnT) and I (TnI) immunoassays. Materials and methods: The study population consisted in 47 consecutive patients presenting at the emergency department (ED) of the Academic Hospital of Parma with suspected AMI. TnI was measu-red with the novel prototype Beckman Coulter HS-AccuTnI immunoassay on Access 2, whereas TnT was measured with the Roche HS-TnT immunoassay on Cobas. Results: Eight out of the 47 patients (17%) were finally diagnosed as having an AMI. The overall cor-relation between TnT and TnI for total patient group was acceptable (r = 0.944; P < 0.01). Neverthe-less, when the analysis of data was carried out in separate groups according to the final diagnosis of AMI, two different equation results were obtained, i.e., HS-TnT = HS-AccuTnI x 0.349 + 20 (r = 0.823; P < 0.01) in non-AMI patients, and HS-TnT = HS-AccuTnI x 0.134 + 67 (r = 0.972; P < 0.01) in those with AMI. Conclusions: This study suggests the existence of two biological relationships between TnI and TnT in plasma, depending on the source of release from the myocardium. Moreover, the non-commutability of data between HS-TnT and HS-AccuTnI jeopardizes the clinical decision making, makes it impossible to calculate the delta or reference change value using the two biomarkers and to finally establish a reliable kinetics of troponin release from the injured myocardium

    The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure

    Get PDF
    Introduction: The phlebotomists’ procedures are a still source of laboratory variability. The aim of this study was to verify the efficacy of minor modification in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document is able to reduce the tourniquet application time. Materials and methods: Thirty phlebotomists were invited to participate. Each phlebotomist was trained individually to perform the new venipuncture procedure that shortens the time of tourniquet release and removal. The phlebotomy training program was delivered over 8h. After training, all phlebotomists were monitored for 20 working days, to guarantee the adoption of the correct new procedures for collection of diagnostic blood specimens. After this time frame the phlebotomists were evaluated to verify whether the new procedure for blood collection derived from CLSI H03-A6 document was effective to improve the quality process by decrease in tourniquet application time. We compared the tourniquet application time and qualitative difference of phlebotomy procedures between laboratories before and after phlebotomy training. Results: The overall mean ± SD tourniquet application time before and after this intervention were 118 ± 1 s and 30 ± 1 s respectively. Minor modifications in procedure for blood collection were able to reduce significantly the tourniquet application time (-88 s, P < 0.001). Conclusions: The minor modifications in procedure for collection of diagnostic blood specimens by venipuncture from CLSI H03-A6 document were able to reduce the tourniquet application time. Now the proposed new procedure for collection of diagnostic blood specimens by venipuncture could be considered usefulness and should be put into practice by all quality laboratory managers and/or phlebotomy coordinators to avoid preanalytical errors regard venous stasis and guarantee patient safety

    Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis

    Get PDF
    Introduction: Glycolysis affects glucose determination in vitro. The placement of sample tubes in ice-water slurry with plasma separation within 30 minutes is recommended, or alternatively the use of a glycolysis inhibitor. The aim of our two-steps study was to evaluate which Terumo tube is best for glucose determination in routine clinical setting. Materials and methods: In the first study, blood from 100 volunteers was collected into lithium heparin (LH), NaF/Na heparin (FH) and NaF/citrate buffer/Na2EDTA (FC-Mixture) tubes. LH sample was treated as recommended and considered as reference, while FH and FC-Mixture samples were aliquoted, maintained at room temperature (RT) for 1, 2 and 4 hours; centrifuged and plasma analysed in triplicate. In the second study, samples from 375 volunteers were collected in LH, FH and FC-Mixture tubes and held at RT before centrifugation from 10 to 340 minutes, depending on each laboratory practice. Samples were analysed in one analytical run. Results: In the first study, FH glucose concentrations were 5.15 ± 0.66 mmol/L, 5.05 ± 0.65 mmol/L and 5.00 ± 0.65 mmol/L (P < 0.001) in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases in all time points exceeded the analytical goal for desirable bias based on biological variation criteria. FC-Mixture glucose concentrations were 5.48 ± 0.65 mmol/L, 5.46 ± 0.6 mmol/L and 5.46 ± 0.64 mmol/L in tubes stored at RT for 1, 2 and 4 hours, respectively. Mean biases for FC-Mixture glucose in all time points reached optimal analytical goals. In the second study, the biases for LH and FH glucose compared to reference FC-Mixture glucose exceeded the preset analytical goals, regardless of the blood collection to centrifugation time interval. Conclusions: FC-mixture tubes glucose concentrations were preserved up to 4h storage at RT. We confirmed that NaF alone does not allow immediate glycolysis inhibition in real life pre-centrifugation storage conditions (up to 340 minutes). FC-Mixture should be used exclusively for glucose determination in laboratories unable to implement the recommended blood samples’ treatment

    Effect of CYP4F2, VKORC1, and CYP2C9 in Influencing Coumarin Dose: A Single-Patient Data Meta-Analysis in More Than 15,000 Individuals

    Get PDF
    The cytochrome P450 (CYP)4F2 gene is known to influence mean coumarin dose. The aim of the present study was to undertake a meta-analysis at the individual patients level to capture the possible effect of ethnicity, gene—gene interaction, or other drugs on the association and to verify if inclusion of CYP4F2*3 variant into dosing algorithms improves the prediction of mean coumarin dose. We asked the authors of our previous meta-analysis (30 articles) and of 38 new articles retrieved by a systematic review to send us individual patients’ data. The final collection consists of 15,754 patients split into a derivation and validation cohort. The CYP4F2*3 polymorphism was consistently associated with an increase in mean coumarin dose (+9% (95% confidence interval (CI) 7–10%), with a higher effect in women, in patients taking acenocoumarol, and in white patients. The inclusion of the CYP4F2*3 in dosing algorithms slightly improved the prediction of stable coumarin dose. New pharmacogenetic equations potentially useful for clinical practice were derived

    Patient posture for blood collection by venipuncture: recall for standardization after 28 years

    Get PDF
    Although data about the effect of posture on routine hematological testing were published 28 years ago, this pre-analytical issue has not been standardized so far. This study was planned to evaluate whether postural changes influence the results of hematology testing. METHODS: A complete blood count was performed in 19 healthy volunteers after 25min in the supine position, 20min in a sitting position and 20min stationary standing in an upright position. RESULTS: The change from supine to sitting position caused clinically significant increases in the hemoglobin, hematocrit and red blood cell count. Furthermore, the change from supine to standing caused clinically significant increases in the hemoglobin, hematocrit, red blood cell, leukocyte, neutrophil, lymphocyte, basophil and platelet counts, and mean platelet volume, and that from sitting to standing caused clinically significant increases in hemoglobin, hematocrit, and red blood cell, leukocyte, neutrophil and lymphocyte counts. CONCLUSION: The results of this investigation provide further support to the notion that effort should be made to achieve widespread standardization in the practice of phlebotomy, including patient posture. Copyright \ua9 2017 Associa\ue7\ue3o Brasileira de Hematologia, Hemoterapia e Terapia Celular. Published by Elsevier Editora Ltda. All rights reserved
    • …
    corecore