442 research outputs found

    Privileged burial in the Pava Pieve (Siena, 8th century AD)

    Get PDF
    During the 6th archaeological excavation campaign performed at the «Pieve di Pava» (San Giovanni d’Asso, Siena, Italy) in the summer of 2009, a stone-lined burial of a high-status single individual (US 2378) was discovered, covered by a monolithic slab and placed in front of the altar. The tomb is about 160 cm long, 40 cm wide and over 70 cm deep. The skeletal remains of a young male (18-20 years), not in anatomical connection, were found on the floor of the tomb. 14C dating revealed a period between 650 and 688 AD. Stable isotope analysis (18O, 13C, 15N) attested that he was a member of the local community, with a diet quite rich in animal proteins. We are in presence of the secondary burial of an eminent personage, perhaps a saint, likely to have been transported to the church in a sack of perishable material, possibly textile, which caused their alignment along a curved line, as clearly demonstrated by the circular delimitation of the bones. The body was probably used for the re-consecration of the church, following the restoration works of the 8th century. The paleopathological study diagnosed a case of acromesomelic dysplasia, a congenital anomaly with disproportionate limbs: short, enlarged distal segments (radius-ulna and tibia), almost normal proximal segments (humerus and femur), short stature of about 150 cm, and bilateral fibular agenesis. Tibiae malformation and fibulae agenesis led to bilateral talipes valgus, with major walking problems. Extensive enthesopathies in the upper limbs indicate the use of crutches

    Dosimetric characterization of CVD diamonds irradiated with 62 MeV proton beams

    Get PDF
    Diamond is potentially a very suitable material for use as on-line radiation dosimeter. Recent advances in the synthesis of polycrystalline diamond by chemical vapor deposition (CVD) techniques have produced material with electronic properties suitable for dosimetry applications. In this work the possibility to use a segmented commercial CVD detector in the dosimetry of proton beams has been investigated. The response as function of dose, dose rate, the priming and the rise time have been investigated thoroughly. This study shows the suitability of CVD diamond for dosimetry of clinical 62 MeV proton beams. r 2005 Elsevier B.V. All rights reserved

    Dosimetric characterization of CVD diamonds in photon, electron and proton beams

    Get PDF
    The purpose of this work is the characterization, in an on line configuration, of the dosimetric response of a commercial CVD diamond. The study shows the possibility of using CVD diamond for dosimetric purposes with clinical, high-energy electron (4-15 MeV), photon (6-15 MV) and proton (62 MeV) beams

    Resistive Plate Chambers with Gd-coated electrodes as thermal neutron detectors

    Get PDF
    Abstract Resistive Plate Chambers (RPCs) are wide spread, cheap, easy-to-build and large size detectors, used mainly to reveal ionising particles in high-energy physics experiments. Here a technique, consisting in coating the inner surface of the bakelite electrodes with a mixture of linseed oil and Gd 2 O 3 is reported. This allows to make RPCs sensitive also to thermal neutrons, making them suitable to be employed for industrial, medical or de-mining applications. Thermal neutron-sensitive RPCs can be operated at atmospheric pressure, are lightweighted, have low Îł -ray sensitivity and are easy to handle even when large areas have to be covered. This paper reports the results of the first test of this detector, performed at the Geel Linear Accelerator (GELINA) in Belgium

    Echocardiography and pulse contour analysis to assess cardiac output in trauma patients.

    Get PDF
    Echocardiography is a valuable technique to assess cardiac output (CO) in trauma patients, but it does not allow a continuous bedside monitoring. Beat-to-beat CO assessment can be obtained by other techniques, including the pulse contour method MostCare. The aim of our study was to compare CO obtained with MostCare (MC-CO) with CO estimated by transthoracic echocardiography (TTE-CO) in trauma patients. METHODS: Forty-nine patients with blunt trauma admitted to an intensive care unit and requiring hemodynamic optimization within 24 hours from admission were studied. TTE-CO and MC-CO were estimated simultaneously at baseline, after a fluid challenge and after the start of vasoactive drug therapy. RESULTS: One hundred sixteen paired CO values were obtained. TTE-CO values ranged from 2.9 to 7.6 L·min-1, and MC-CO ranged from 2.8 to 8.2 L·min-1. The correlation between the two methods was 0.94 (95% confidence interval [CI] = 0.89 to 0.97; p<0.001). The mean bias was -0.06 L·min-1 with limits of agreements (LoA) of -0.94 to 0.82 L·min-1 (lower 95% CI, -1.16 to -0.72; upper 95% CI, 0.60 to 1.04) and a percentage error of 18%. Changes in CO showed a correlation of 0.91 (95% CI = 0.87 to 0.95; p<0.001), a mean bias of - 0.01 L·min-1 with LoA of -0.67 to 0.65 L·min-1 (lower 95% CI, -0.83 to -0.51; upper 95% CI, 0.48 to 0.81). CONCLUSION: CO measured by MostCare showed good agreement with CO obtained by transthoracic echocardiography. Pulse contour analysis can complement echocardiography in evaluating hemodynamics in trauma patients

    Status of the Cylindical-GEM project for the KLOE-2 Inner Tracker

    Full text link
    The status of the R&D on the Cylindrical-GEM (CGEM) detector foreseen as Inner Tracker for KLOE-2, the upgrade of the KLOE experiment at the DAFNE phi-factory, will be presented. The R&D includes several activities: i) the construction and complete characterization of the full-size CGEM prototype, equipped with 650 microns pitch 1-D longitudinal strips; ii) the study of the 2-D readout with XV patterned strips and operation in magnetic field (up to 1.5T), performed with small planar prototypes in a dedicated test at the H4-SPS beam facility; iii) the characterization of the single-mask GEM technology for the realization of large-area GEM foils.Comment: 4 pages, 10 figures, Presented at Vienna Conference on Instrumentation (Feb 15-20, 2010, Vienna, Austria). Submitted to the Proceeding

    The game of trading jobs for emissions

    Get PDF
    Following the debate on the implications of international trade for global climate policy, this paper introduces the topic of the economic benefits from trade obtained by exporting countries in relation to the emissions generated in the production of exports. In 2008, 24% of global greenhouse gas (GHG) emissions and 20% of the employment around the world were linked to international trade. China “exported” 30% of emissions and hosted 37.5% of the jobs generated by trade worldwide. The European Union and the United States of America were the destination of 25% and 18.4% of the GHG emissions embodied in trade. The imports of these two regions contributed to the creation of 45% of the employment generated by international trade. This paper proposes the idea of including trade issues in international climate negotiations, taking into account not only the environmental burden generated by developed countries when displacing emissions to developing countries through their imports, but also the economic benefits of developing countries producing the goods exported to developed countries

    A Monitoring Framework with Integrated Sensing Technologies for Enhanced Food Safety and Traceability

    Get PDF
    A novel and low-cost framework for food traceability, composed by commercial and proprietary sensing devices, for the remote monitoring of air, water, soil parameters and herbicide contamination during the farming process, has been developed and verified in real crop environments. It offers an integrated approach to food traceability with embedded systems supervision, approaching the problem to testify the quality of the food product. Moreover, it fills the gap of missing low-cost systems for monitoring cropping environments and pesticides contamination, satisfying the wide interest of regulatory agencies and final customers for a sustainable farming. The novelty of the proposed monitoring framework lies in the realization and the adoption of a fully automated prototype for in situ glyphosate detection. This device consists of a custom-made and automated fluidic system which, leveraging on the Molecularly Imprinted Polymer (MIP) sensing technology, permits to detect unwanted glyphosate contamination. The custom electronic mainboard, called ElectroSense, exhibits both the potentiostatic read-out of the sensor and the fluidic control to accomplish continuous unattended measurements. The complementary monitored parameters from commercial sensing devices are: temperature, relative humidity, atmospheric pressure, volumetric water content, electrical conductivity of the soil, pH of the irrigation water, total Volatile Organic Compounds (VOCs) and equivalent CO (Formula presented.). The framework has been validated during the olive farming activity in an Italian company, proving its efficacy for food traceability. Finally, the system has been adopted in a different crop field where pesticides treatments are practiced. This has been done in order to prove its capability to perform first level detection of pesticide treatments. Good correlation results between chemical sensors signals and pesticides treatments are highlighted

    Analysis of factors influencing the ultrasonic fetal weight estimation

    Get PDF
    Objective: The aim of our study was the evaluation of sonographic fetal weight estimation taking into consideration 9 of the most important factors of influence on the precision of the estimation. Methods: We analyzed 820 singleton pregnancies from 22 to 42 weeks of gestational age. We evaluated 9 different factors that potentially influence the precision of sonographic weight estimation ( time interval between estimation and delivery, experts vs. less experienced investigator, fetal gender, gestational age, fetal weight, maternal BMI, amniotic fluid index, presentation of the fetus, location of the placenta). Finally, we compared the results of the fetal weight estimation of the fetuses with poor scanning conditions to those presenting good scanning conditions. Results: Of the 9 evaluated factors that may influence accuracy of fetal weight estimation, only a short interval between sonographic weight estimation and delivery (0-7 vs. 8-14 days) had a statistically significant impact. Conclusion: Of all known factors of influence, only a time interval of more than 7 days between estimation and delivery had a negative impact on the estimation
    • …
    corecore