124 research outputs found

    Development of a single retention time prediction model integrating multiple liquid chromatography systems: Application to new psychoactive substances.

    Full text link
    Database-driven suspect screening has proven to be a useful tool to detect new psychoactive substances (NPS) outside the scope of targeted screening; however, the lack of retention times specific to a liquid chromatography (LC) system can result in a large number of false positives. A singular stream-lined, quantitative structure-retention relationship (QSRR)-based retention time prediction model integrating multiple LC systems with different elution conditions is presented using retention time data (n = 1281) from the online crowd-sourced database, HighResNPS. Modelling was performed using an artificial neural network (ANN), specifically a multi-layer perceptron (MLP), using four molecular descriptors and one-hot encoding of categorical labels. Evaluation of test set predictions (n = 193) yielded coefficient of determination (R2) and mean absolute error (MAE) values of 0.942 and 0.583 min, respectively. The model successfully differentiated between LC systems, predicting 54%, 81% and 97% of the test set within ±0.5, ±1 and ±2 min, respectively. Additionally, retention times for an analyte not previously observed by the model were predicted within ±1 min for each LC system. The developed model can be used to predict retention times for all analytes on HighResNPS for each participating laboratory's LC system to further support suspect screening

    Interleukin-2 therapy in patients with HIV infection

    Get PDF
    BACKGROUND Used in combination with antiretroviral therapy, subcutaneous recombinant interleukin-2 raises CD4+ cell counts more than does antiretroviral therapy alone. The clinical implication of these increases is not known. METHODS We conducted two trials: the Subcutaneous Recombinant, Human Interleukin-2 in HIV-Infected Patients with Low CD4+ Counts under Active Antiretroviral Therapy (SILCAAT) study and the Evaluation of Subcutaneous Proleukin in a Randomized International Trial (ESPRIT). In each, patients infected with the human immunodeficiency virus (HIV) who had CD4+ cell counts of either 50 to 299 per cubic millimeter (SILCAAT) or 300 or more per cubic millimeter (ESPRIT) were randomly assigned to receive interleukin-2 plus antiretroviral therapy or antiretroviral therapy alone. The interleukin-2 regimen consisted of cycles of 5 consecutive days each, administered at 8-week intervals. The SILCAAT study involved six cycles and a dose of 4.5 million IU of interleukin-2 twice daily; ESPRIT involved three cycles and a dose of 7.5 million IU twice daily. Additional cycles were recommended to maintain the CD4+ cell count above predefined target levels. The primary end point of both studies was opportunistic disease or death from any cause. RESULTS In the SILCAAT study, 1695 patients (849 receiving interleukin-2 plus antiretroviral therapy and 846 receiving antiretroviral therapy alone) who had a median CD4+ cell count of 202 cells per cubic millimeter were enrolled; in ESPRIT, 4111 patients (2071 receiving interleukin-2 plus antiretroviral therapy and 2040 receiving antiretroviral therapy alone) who had a median CD4+ cell count of 457 cells per cubic millimeter were enrolled. Over a median follow-up period of 7 to 8 years, the CD4+ cell count was higher in the interleukin-2 group than in the group receiving antiretroviral therapy alone--by 53 and 159 cells per cubic millimeter, on average, in the SILCAAT study and ESPRIT, respectively. Hazard ratios for opportunistic disease or death from any cause with interleukin-2 plus antiretroviral therapy (vs. antiretroviral therapy alone) were 0.91 (95% confidence interval [CI], 0.70 to 1.18; P=0.47) in the SILCAAT study and 0.94 (95% CI, 0.75 to 1.16; P=0.55) in ESPRIT. The hazard ratios for death from any cause and for grade 4 clinical events were 1.06 (P=0.73) and 1.10 (P=0.35), respectively, in the SILCAAT study and 0.90 (P=0.42) and 1.23 (P=0.003), respectively, in ESPRIT. CONCLUSIONS Despite a substantial and sustained increase in the CD4+ cell count, as compared with antiretroviral therapy alone, interleukin-2 plus antiretroviral therapy yielded no clinical benefit in either study. (ClinicalTrials.gov numbers, NCT00004978 [ESPRIT] and NCT00013611 [SILCAAT study].

    Resveratrol inhibits benzo[a]pyrene–DNA adduct formation in human bronchial epithelial cells

    Get PDF
    Resveratrol ( trans-3,4’,5-trihydroxystilbene), a phytoalexin present in various plants and foods, has in several in vitro and in vivo studies demonstrated cancer chemopreventive and chemotherapeutic potential. We investigated the in vitro effect of resveratrol on benzo[ a] pyrene ( B[ a] P)-induced DNA adducts in human bronchial epithelial cells. This was compared to the effect of resveratrol on the expression of the cytochrome P450 (CYP) genes CYP1A1 and CYP1B1 and the formation of B[ a] P metabolites. Exposure of BEAS-2B and BEP2D cells to B[ a] P and increasing concentrations of resveratrol resulted in a dose- and time-dependent inhibition of DNA adduct formation quantified by P-32-postlabelling. Supporting this result, resveratrol was shown to inhibit CYP1A1 and CYP1B1 gene expression, as measured by real-time reverse transcriptase - polymerase chain reaction. Also, a significant correlation was found between the number of DNA adducts and the mRNA levels of these genes. Using HPLC analysis, a concomitant decrease in the formation of B[ a]P-derived metabolic products was detected. In conclusion, these data lend support to a chemopreventive role of resveratrol in polycyclic aromatic hydrocarbon-induced carcinogenesis

    Mass Spectrometric Mapping of the DNA Adductome as a Means to Study Genotoxin Exposure, Metabolism, and Effect.

    Get PDF
    Covalent binding of endo- or exogenous chemicals to DNA results in the formation of DNA adducts which are reflective of exposure of the human body to DNA-damaging molecules and their metabolic pathways. The study of DNA adduct types and levels in human tissue therefore offers an interesting tool in several fields of research, including toxicology and cancer epidemiology. Over the years, a range of techniques and methods have been developed to study the formation of endo- and exogenous DNA adducts. However, for the simultaneous detection, identification and quantification of both known and unknown DNA adducts, mass spectrometry (MS) is deemed to be the most promising technique. In this perspective, we focus on the analysis of multiple DNA adducts within a sample with the emphasis on untargeted analysis. The advantageous use of MS methodologies for DNA adductome mapping is discussed comprehensively with relevant field examples. In addition, several aspects of study design, sample pretreatment, and analysis are addressed as these factors significantly affect the reliability of DNA adductomics studies

    Metagenomic analysis reveals previously undescribed bat coronavirus strains in Eswatini

    Get PDF
    We investigated the prevalence of coronaviruses in 44 bats from four families in northeastern Eswatini using high-throughput sequencing of fecal samples. We found evidence of coronaviruses in 18% of the bats. We recovered full or near-full-length genomes from two bat species: Chaerephon pumilus and Afronycteris nana, as well as additional coronavirus genome fragments from C. pumilus, Epomophorus wahlbergi, Mops condylurus, and Scotophilus dinganii. All bats from which we detected coronaviruses were captured leaving buildings or near human settlements, demonstrating the importance of continued surveillance of coronaviruses in bats to better understand the prevalence, diversity, and potential risks for spillover.The National Science Foundation Graduate Research Fellowship; a National Science Foundation Graduate Research Opportunities Worldwide grant; Innovation Fund Denmark; a Student Research Grant from Bat Conservation International; a University of Florida Biodiversity Institute Fellowship; the Zuckerman STEM Leadership Program and an NIH Grant.http://link.springer.com/journal/10393hj2022Mammal Research InstituteZoology and Entomolog

    Pre-Flight Calibration of the Mars 2020 Rover Mastcam Zoom (Mastcam-Z) Multispectral, Stereoscopic Imager

    Get PDF
    The NASA Perseverance rover Mast Camera Zoom (Mastcam-Z) system is a pair of zoomable, focusable, multi-spectral, and color charge-coupled device (CCD) cameras mounted on top of a 1.7 m Remote Sensing Mast, along with associated electronics and two calibration targets. The cameras contain identical optical assemblies that can range in focal length from 26 mm (25.5∘×19.1∘ FOV) to 110 mm (6.2∘×4.2∘ FOV) and will acquire data at pixel scales of 148-540 μm at a range of 2 m and 7.4-27 cm at 1 km. The cameras are mounted on the rover’s mast with a stereo baseline of 24.3±0.1 cm and a toe-in angle of 1.17±0.03∘ (per camera). Each camera uses a Kodak KAI-2020 CCD with 1600×1200 active pixels and an 8 position filter wheel that contains an IR-cutoff filter for color imaging through the detectors’ Bayer-pattern filters, a neutral density (ND) solar filter for imaging the sun, and 6 narrow-band geology filters (16 total filters). An associated Digital Electronics Assembly provides command data interfaces to the rover, 11-to-8 bit companding, and JPEG compression capabilities. Herein, we describe pre-flight calibration of the Mastcam-Z instrument and characterize its radiometric and geometric behavior. Between April 26thth and May 9thth, 2019, ∼45,000 images were acquired during stand-alone calibration at Malin Space Science Systems (MSSS) in San Diego, CA. Additional data were acquired during Assembly Test and Launch Operations (ATLO) at the Jet Propulsion Laboratory and Kennedy Space Center. Results of the radiometric calibration validate a 5% absolute radiometric accuracy when using camera state parameters investigated during testing. When observing using camera state parameters not interrogated during calibration (e.g., non-canonical zoom positions), we conservatively estimate the absolute uncertainty to be 0.2 design requirement. We discuss lessons learned from calibration and suggest tactical strategies that will optimize the quality of science data acquired during operation at Mars. While most results matched expectations, some surprises were discovered, such as a strong wavelength and temperature dependence on the radiometric coefficients and a scene-dependent dynamic component to the zero-exposure bias frames. Calibration results and derived accuracies were validated using a Geoboard target consisting of well-characterized geologic samples
    • …
    corecore