67 research outputs found

    Differential effects of tissue plasminogen activator and streptokinase on infarct size and on rate of enzyme release: influence of early infarct related artery patency: The GUSTO Enzyme Substudy

    Get PDF
    Background The recent international GUSTO trial of 41 021 patients with acute myocardial infarction demonstrated improved 90-mm infarct related artery patency as well as reduced mortality in patients treated with an accelerated regimen of tissue plasminogen activator, compared to patients treated with streptokinase. A regimen combining tissue plasminogen activator and streptokinase yielded intermediate results. The present study investigated the effects of treatment on infarct size and enzyme release kinetics in a subgroup of these patients. Methods A total of 553 patients from 15 hospitals were enrolled in the study. Four thrombolytic strategies were compared: streptokinase with subcutaneous heparin, streptokinase with intravenous (iv.) heparin, tissue plasminogen activator with iv. heparin, and streptokinase plus tissue plasminogen activator with i.v. heparin. The activity of alpha-hydroxybutyrate dehydrogenase (HBDH) in plasma was centrally analysed and infarct size was defined as cumulative HBDH release per litre of plasma within 72 h of the first symptoms (Q(72)). Patency of the infarct-related vessel was determined by angiography in 159 patients, 90 mm after treatment. Results Infarct size was 3·72 g-eq . 1−1 in patients with adequate coronary perfusion (TIMI-3) at the 90 mm angi-ogram and larger in patients with TIMI-2 (4·35 g-eq . 1−1) or TIMI 0-1 (5·07 g-eq . 1−1)flow (P=0·024). In this subset of the GUSTO angiographic study, early coronary patency rates (TIMI 2+3) were similar in the two streptokinase groups (53 and 46%). Higher, but similar, patency rates were observed in the tissue plasminogen activator and combination therapy groups (87 and 90%). Median infarct size for the four treatment groups, expressed in gram- equivalents (g-eq) of myocardium, was 4·4, 4·5, 3·9 and 3·9 g-eq per litre of plasma (P=0·04 for streptokinase vs tissue plasminogen activator). Six hours after the first symptoms, respectively 5·3, 6·6, 14·0 and 13·6% of total HBDH release was complete (P<0·000l for streptokinase vs tissue plasminogen activator). Conclusions Rapid and complete coronary reperfusion salvages myocardial tissue, resulting in limitation of infarct size and accelerated release of proteins from the myocardium. Treatment with tissue plasminogen activator, resulting in earlier reperfusion was more effective in reducing infarct size than the streptokinase regimens, which contributes to the differences in survival between treatment groups in the GUSTO tria

    Tissue Doppler echocardiography – A case of right tool, wrong use

    Get PDF
    BACKGROUND: The developments in echocardiography or ultrasound cardiography (UCG) have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE) is one such example? PRESENTATION OF THE HYPOTHESIS: TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. TESTING THE HYPOTHESIS: To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. IMPLICATIONS OF THE HYPOTHESIS: As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist

    Reverse left ventricular remodeling is more likely in non ischemic cardiomyopathy patients upgraded to biventricular stimulation after chronic right ventricular pacing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Chronic right ventricular (RV) apical pacing may lead to left ventricular (LV) dyssynchrony and LV dysfunction. In heart failure due to RV pacing, upgrading to biventricular stimulation (CRT) can improve NYHA Class and LV function. A proportion of patients do not respond to upgrading. Aim was to assess whether etiology of LV dysfunction accounts for responses to CRT in RV-paced patients.</p> <p>Methods</p> <p>Sixty-two patients treated by CRT, under RV pacing from 50.2 ± 5.4 months, were studied. Cause of LV dysfunction was non-ischemic (NIC) in 28 and ischemic cardiomyopathy (IC) in 34 patients. Clinical and conventional echocardiographic parameters were available within 1 month before RV pacing, within 1 month before CRT and at 12 ± 2 months of follow-up (FU).</p> <p>Results</p> <p>Decreased LVEF (from 37.0 ± 8.8 to 25.6 ± 6.1%, p <0.001), increased LV end-systolic dimensions (LVESD) (from 48.1 ± 8.6 to 55.2 ± 7.9 mm, p <0.001) and worsened NYHA Class (from 1.9 ± 1.1 to 3.2 ± .6, p < 0.005) were found before CRT, compared to pre RV-pacing. After CRT, 44/62 patients showed a ≥ 1 NYHA Class improvement; >10% decrease in LVESD was observed in 24 patients: 5 with IC, 19 with NIC (p < .0.001). The association between cause of LV dysfunction with >10% decrease in LVESD remained highly significant (p < 0.001) adjusting for pre-CRT QRS duration, NYHA Class, LVEF, LVESD, treatment or RV pacing duration.</p> <p>Conclusions</p> <p>CRT improves functional class even after long-lasting pacing. Reverse remodeling is evident in a small population, more likely with NIC.</p

    Acute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy

    Get PDF
    Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized optimization of device based AV delays and VV intervals compared to empiric programming.25 recipients of CRT (male: 56%, mean age: 67 years) were included in this study. Ejection fraction (EF), the primary outcome parameter, and left ventricular (LV) dimensions were evaluated by 3DE before CRT (baseline), after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming) and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI) was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI), calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation), and the VV interval with the lowest SDI was programmed (individualized optimization).EF increased from baseline 23±7% to 30±8 (p<0.001) after AV delay optimization and to 32±8% (p<0.05) after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001). Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001).Compared with empiric programming of biventricular pacemakers, individualized echocardiographic optimization with the integration of 3-dimensional indices into the optimization protocol acutely improved LV systolic function and decreased ESV and can be used to select the optimal AV delay and VV interval in CRT
    corecore