11 research outputs found

    Results of a phase 1, randomized, placebocontrolled first-in-human trial of griffithsin formulated in a carrageenan vaginal gel

    Full text link
    HIV pre-exposure prophylaxis (PrEP) is dominated by clinical therapeutic antiretroviral (ARV) drugs. Griffithsin (GRFT) is a non-ARV lectin with potent anti-HIV activity. GRFT’s preclinical safety, lack of systemic absorption after vaginal administration in animal studies, and lack of cross-resistance with existing ARV drugs prompted its development for topical HIV PrEP. We investigated safety, pharmacokinetics (PK), pharmacodynamics (PD), and immunogenicity of PC-6500 (0.1% GRFT in a carrageenan (CG) gel) in healthy women after vaginal administration. This randomized, placebo-controlled, parallel group, double-blind first-in-human phase 1 study enrolled healthy, HIV-negative, non-pregnant women aged 24–45 years. In the open label period, all participants (n = 7) received single dose of PC- 6500. In the randomized period, participants (n = 13) were instructed to self-administer 14 doses of PC-6500 or its matching CG placebo (PC-535) once daily for 14 days. The primary outcomes were safety and PK after single dose, and then after 14 days of dosing. Exploratory outcomes were GRFT concentrations in cervicovaginal fluids, PD, inflammatory mediators and gene expression in ectocervical biopsies. This trial is registered with ClinicalTrials. gov, number NCT02875119. No significant adverse events were recorded in clinical or laboratory results or histopathological evaluations in cervicovaginal mucosa, and no anti-drug (GRFT) antibodies were detected in serum. No cervicovaginal proinflammatory responses and no changes in the ectocervical transcriptome were evident. Decreased levels of proinflammatory chemokines (CXCL8, CCL5 and CCL20) were observed. GRFT was not detected in plasma. GRFT and GRFT/CG in cervicovaginal lavage samples inhibited HIV and HPV, respectively, in vitro in a dose-dependent fashion. These data suggest GRFT formulated in a CG gel is a safe and promising on-demand multipurpose prevention technology product that warrants further investigation

    Contribution to Synchronization and Tracking Modelisation in a CDMA Receiver

    No full text
    We propose and analyze a noncoherent receiver with PN code tracking for direct sequence code division multiple access (DS-CDMA) communication systems. We employ the delay-lock loop (DLL) architectures for the tracking stage. The choice of DLL parameters is studied with special focus on DS-CDMA communication systems and orthogonality conditions. We described the modeling and simulation of the NCO using hardware description language VHDL. Details of the VHDL implementation are shown

    Isolated radial volar dislocation of the fifth carpometacarpal joint :a rare injury Case report Open Access

    No full text
    Abstract Isolated palmar dislocation of the fifth carpometacarpal joint is an uncommon injury and classified as radio-palmar or ulno-palmar according to the direction of displacement of the fifth metacarpal base . This very rare injury is often difficult to recognize. A careful neurologic assessment of the patient is a necessity, as well as obtaining proper radiographs of the hand. The purpose of this report is to present a patient with a pure isolated volar dislocation of the fifth carpometacarpal joint that was satisfactorily treated with closed reduction and casting. A review of the literature is presented

    Progesterone vaginal ring as a new contraceptive option for lactating mothers: Evidence from a multicenter non-randomized comparative clinical trial in India

    No full text
    Objectives: Evaluate and compare contraceptive efficacy, safety, continuation rates and duration of lactational amenorrhea (LA) in married lactating women (20-35 years) using the progesterone vaginal ring (PVR) or Copper-T380A intrauterine device (IUD) during the first postpartum year. Study design: We conducted a one-year multicenter, non-randomized, non-inferiority, open-label, comparative trial at 20 centers in India and compared efficacy, safety, continuation and LA plus feeding patterns and growth/well-being of participants’ infants. Women used four 3-month PVRs consecutively (lost PVRs were not replaced) and were to breastfeed at least four times/day. We used Pearl Index (PI) and Kaplan Meier (K-M) rates to analyze pregnancy and K-M for continuation. Results: We enrolled 789 women (459 PVR, 330 IUD). Neither PI nor K-M one-year pregnancy rates differed significantly between groups (PI: PVR-0.62; IUD-0.35); (K-M: PVR-0.7; IUD-0.4, p=0.58). Continuation rates at 12 months were 78.5% (IUD) vs. 56.9% (PVR) (p \u3c 0.001). Ring expulsions and menorrhagia were the most common discontinuation among PVR/ IUD users respectively. The median duration of LA among PVR vs. IUD users was 405 vs. 120 days (p \u3c 0.001). Both groups reported similar adverse events (PVR: 24.2%; IUD: 23.0%); there were no serious adverse events among PVR users. Infants from both groups fed 12-7 times/day and grew at expected rates. Conclusions: Efficacy and safety outcomes were comparable among women in both groups. Continuation rates for PVR, a woman-controlled method, were shorter than IUD rates while PVR users maintained LA significantly longer than IUD users. Infant breastfeeding and growth patterns/well-being were favorable in both groups. Implications: PVR, a user-controlled device, offers an additional contraceptive choice for lactating women for one-year postpartum use and can help to address the unmet need for contraception among postpartum women while encouraging breastfeeding to enhance infant growth and well-being

    Effects of concurrent vaginal miconazole treatment on the absorption and exposure of Nestorone® (segesterone acetate) and ethinyl estradiol delivered from a contraceptive vaginal ring: A randomized, crossover drug–drug interaction study

    No full text
    Objectives: To evaluate the effects of concurrent administration of three vaginal miconazole nitrate formulations on the absorption and exposure of Nestorone® (segesterone acetate) and ethinyl estradiol from a novel contraceptive vaginal ring (NES/EE CVR). Study design: This was an open-label, randomized, crossover, drug-drug interaction study conducted over three menstrual cycles in healthy women with regular menses. We compared systemic exposure to NES and EE by determining area under the curve (AUC_8–21d) with CVR-only and CVR with each miconazole treatment. Three different miconazole formulations (single dose suppository, multiple dose suppository or multiple dose cream) were administered in a single dose on day 8 or multiple doses on days 8–10 after CVR insertion. We evaluated safety and tolerability of the CVR in the presence of antimycotic co-medication. Results: 45 participants were randomized and 29 completed participation. Systemic exposure to NES and EE released from the CVR increased with single or multiple doses of miconazole suppositories but not with multiple dose cream. The maximum EE geometric mean ratio (GMR) for AUC_8–21d was 1.67 (1.51–1.86) for single dose and 1.42 (1.21–1.66) for multiple dose suppositories. By contrast, systemic exposure to NES and EE was comparable with and without miconazole cream (all GMRs and confidence intervals within 0.80 to 1.25). Adverse events (AEs) were similar with CVR only and with all miconazole treatment groups. There were no serious treatment related AEs. Conclusions: Miconazole vaginal suppositories were associated with increased systemic levels of NES and EE, while systemic exposure with miconazole vaginal cream was comparable to no-miconazole exposure. Implications: Co-administration of miconazole suppositories with the investigational NES/EE CVR led to higher systemic exposure of both hormones, while co-administration with miconazole cream did not affect hormone levels. Women utilizing the NES/EE CVR may be advised to use an oral formulation or miconazole cream rather than suppository to treat vaginal candidiasis

    A first-in-human trial of MIV-150 and zinc acetate co-formulated in a carrageenan gel: Safety, pharmacokinetics, acceptability, adherence and pharmacodynamics

    No full text
    Objective: To evaluate the safety and pharmacokinetics (PK) of MIV-150 and zinc acetate in a carrageenan gel (PC-1005). Acceptability, adherence, and pharmacodynamics (PD) were also explored. Design: A 3-day open label safety run-in (n=5) preceded a placebo-controlled, double-blind trial in healthy, HIV-negative, abstinent women randomized (4:1) to vaginally apply 4 mL of PC-1005 or placebo once daily for 14d. Methods: Assessments included physical exams, safety labs, colposcopy, biopsies, cervicovaginal lavages (CVLs), and behavioral questionnaires. MIV-150 (plasma, CVL, tissue), zinc (plasma, CVL), and carrageenan (CVL) concentrations were determined with LCMS-MS, ICP-MS, and ELISA, respectively. CVL antiviral activity was measured using cell-based assays. Safety, acceptability and adherence were analyzed descriptively. PK parameters were calculated using non-compartmental techniques and actual sampling times. CVL antiviral EC50 values were calculated using a dose-response inhibition analysis. Results: Participants (n=20) ranged from 19-44 years old; 52% were Black or African American. Among those completing the trial (13/17, PC-1005; 3/3, placebo), 11/17 reported liking the gel overall; 7 recommended reducing the volume. Adverse events, which were primarily mild and/or unrelated, were comparable between groups. Low systemic MIV-150 levels were observed, without accumulation. Plasma zinc levels were unchanged from baseline. 7/7 CVLs collected 4h post-dose demonstrated antiviral (HIV, HPV) activity. High baseline CVL anti-HSV-2 activity precluded assessment of post-dose activity. Conclusion: PC-1005 used vaginally for 14d was well-tolerated. Low systemic levels of MIV-150 were observed. Plasma zinc levels were unchanged. Post-dose CVLs had anti-HIV and anti-HPV activity. These data warrant further development of PC-1005 for HIV and STI prevention

    A dose-finding, cross-over study to evaluate the effect of a Nestorone®/Estradiol transdermal gel delivery on ovulation suppression in normal ovulating women

    No full text
    Objective: This study aims to determine the lowest effective of three Nestorone (NES)/estradiol (E2) transdermal gel doses to ensure ovulation suppression in 90–95% of cycles. Methods: This was a randomized, open-label, three-treatment-period cross-over study to evaluate the effects of NES/E2 transdermal gel on ovulation inhibition, suppression of follicular growth and pharmacokinetic parameters. The doses were low (1.5 mg NES/0.5 mg E2), medium (3.0 mg NES/1.0 mg E2) and high (4.5 mg NES/1.5 mg E2). Participants applied gel daily to a fixed area on the abdomen for 21 consecutive days. They were interviewed regarding their experiences using the gel. Results: Eighteen participants were randomized; 16 completed the study. Median NES Cmax values for low, medium and high dose groups at day 21 were 318.6 pmol/L, 783.0 pmol/L and 1063.8 pmol/L, respectively. Median maximum follicular diameter was higher with the lowest dose with 16.2 mm versus 10.0 and 10.4 mm with the medium and high doses, respectively. Among adherent participants, ovulation was inhibited in all dose groups, except for one participant in the medium dose (6.7%) that had luteal activity and an ultrasound image suggestive of a luteinized unruptured follicle. There were few reports of unscheduled bleeding, with more episodes reported for the lower dose. Adverse events were mild, and no skin irritation was reported from gel application. Conclusion: While all three doses blocked ovulation effectively and were evaluated as safe and acceptable, the medium dose was considered the lowest effective dose based on a more adequate suppression of follicular development. Further development of this novel contraceptive delivering NES and E2 is warranted and has potential for improved safety compared to ethinyl-estradiol-based methods

    Segesterone acetate/ethinyl estradiol 12-month contraceptive vaginal system safety evaluation

    Get PDF
    Objectives: To evaluate safety outcomes from clinical studies of a 12-month contraceptive vaginal system (CVS) releasing an average of segesterone acetate (SA) 150 mcg and ethinyl estradiol (EE) 13 mcg daily. Study design: We integrated clinical safety data from nine studies in which women used the CVS for 21 consecutive days and removed it for 7 days of each 28-day cycle. Four studies used the final manufactured CVS, including a 1-year pharmacokinetic study, two 1-year phase 3 trials and a second-year treatment extension study. We assessed safety by evaluating adverse events women reported in a daily diary. We also included data from focused safety studies evaluating endometrial biopsies, vaginal microbiology and liver proteins from one of the phase 3 studies. Results: The combined studies included 3052 women; 2308 women [mean age 26.7±5.1 years; mean body mass index (BMI) 24.1±3.7 kg/m2] received the final manufactured CVS, of whom 999 (43.3%) completed 13 cycles of use. Women using the final CVS most commonly reported adverse events of headache (n=601, 26%), nausea (n=420, 18%), vaginal discharge/vulvovaginal mycotic infection (n=242, 10%) and abdominal pain (n=225, 10%). Few ( \u3c 1.5%) women discontinued for these complaints. Four (0.2%) women experienced venous thromboembolism (VTE), three of whom had risk factors for thrombosis [Factor V Leiden mutation (n=1); BMI \u3e 29 kg/m2 (n=2)]. During 21,482 treatment cycles in the phase 3 studies evaluable for expulsion, women reported partial expulsions in 4259 (19.5%) cycles and complete expulsions in 1509 (7%) cycles, most frequently in the initial cycle [499/2050 (24.3%) and 190/2050 (9.3%), respectively]. Safety-focused studies revealed no safety concerns. Conclusion: The 1-year SA/EE CVS has an acceptable safety profile. Additional studies are warranted in obese women at higher risk of VTE. Implications: This 1-year contraceptive vaginal system represents a new long-term, user-controlled and procedure-free option with a safety profile similar to other combination hormonal contraceptives. The same precautions currently used for combination hormonal contraceptive prescriptions apply to this new contraceptive vaginal system
    corecore