    Науково-практичне обґрунтування процедури терапевтичного лікарського моніторингу на прикладі вальпроєвої кислоти: валідація аналітичної методики

    Get PDF
    The need for careful therapeutic drug monitoring (TDM) arises for measurement of drugs with a narrow therapeutic index (NTIDs), as well as for assuring their safe and controlled replacement with generics. In particular, this category includes anti-epileptic drugs, which use is associated with the range of issues during the management of therapy effectiveness and safety. One of these examples is valproic acid, which therapeutic concentrations vary greatly depending on the individual patient. The need to substantiate the choice and control of individual optimal dosing regimen of drugs, as well as to provide the rational use of generic NTIDs, determines the relevance of the introduction of TLM in the routine practice of standardized medical care for certain categories of patients, and it requires appropriate scientific and practical justification.Aim. To provide the scientific and practical substantiation of the procedure of TDM by validation of the laboratory method for determining the concentration of valproic acid in the blood plasma.Materials and methods. Analytical, statistical and biological methods were used in the study. Measurement of valproic acid concentration in a standardized sample of the blood plasma was performed by the photometric method using reagents produced by SIEMENS, Inc., USA and the control serum “Chemical control, level1” produced by Bio-Rad, Inc., USA. Measurements were made by a Siemens Bio Dimension RxL Max automatic biochemical analyzer.Results. The limits of intra-laboratory reproducibility by the factor of the laboratory assistant have been estimated as R = 3.25. The assessment of the repeatability and reproducibility of the method by the time factor and in different concentration ranges has shown the absence of gross errors and statistically significant differences in the measurements. It has been found that in the range of 73.8 ± 110 µg/ml valproic acid concentration values determined by this method using the Siemens Dimension RxL Max device can be considered accurate and reliable. The linearity of this method within the range of the concentrations measured has been also proven; it confirms the possibility of its use for measuring the concentration of valproic acid in the blood plasma.Conclusions. The scientific and practical substantiation obtained is necessary for the proper implementation of TDM in the process of providing medical care to particular categories of patients to optimize the individual dosing regimen of NTIDs. In addition, validation of the TDM method allows using it for assuring the safe and controlled generic replacement of NTIDs. The results of the work can be used in the process of further improvement and development of new analytical methods for TDM of valproic acid, as well as other NTIDs.Проведение тщательного терапевтического лекарственного мониторинга (ТЛМ) является актуальным при применении лекарственных препаратов с узким терапевтическим индексом (NTIDs), а также при осуществлении их безопасной и контролированной генерической замены. К этой категории относятся противоэпилептические препараты, применение которых связано с трудностями контроля эффективности и безопасности лечения. Одним из таких примеров является вальпроевая кислота, терапевтические концентрации которой варьируются у каждого конкретного пациента. Необходимость обоснования выбора и контроля индивидуального оптимального режима дозирования лекарственных средств, а также обеспечения рационального применения генерических NTIDs обусловливает актуальность внедрения ТЛМ в рутинную практику стандартизированной медицинской помощи отдельным категориям пациентов, что требует соответствующего научно-практического обоснования.Цель исследования. Научно-практическое обоснование процедуры лекарственного мониторинга путем валидации лабораторной методики определения концентрации вальпроевой кислоты в плазме крови.Материалы и методы. В процессе работы использовались аналитические, статистические и биологические методы. Измерение концентрации вальпроевой кислоты в стандартных образцах плазмы крови проводилось фотометрическим методом с использованием реактивов производства SIEMENS, Inc., USA и контрольной сыворотки «Химический контроль, урoвень 1» производства Bio-Rad, Inc., USA. Измерения выполнялись на автоматическом биохимическом анализаторе Siemens Dimension RxL Max.Результаты. Оценка границы внутрилабораторной воспроизводимости по фактору оператор-лаборант составила R = 3,25. Оценка повторяемости и воспроизводимости методики по фактору времени и в разных диапазонах концентраций показала отсутствие грубых ошибок в работе анализатора и статистически важных отличий при проведении измерений. В диапазоне 73,8±110 мкг/мл значения концентраций вальпроевой кислоты, установленные с помощью исследуемой методики на приборе Siemens Dimension RxL Max, можно считать точными и достоверными. Также показана линейность данной методики в диапазоне измеряемых концентраций, что подтверждает возможность её использования для измерения концентрации вальпроевой кислоты в плазме крови.Выводы. Научно-практическое обоснование, полученное в ходе работы, является необходимым для надлежащей имплементации процедуры ТЛМ в процесс оказания стандартизированной медицинской помощи отдельным категориям пациентов с целью оптимизации индивидуального режима дозирования NTIDs. Кроме того, валидация методик ТЛМ позволяет использовать его для осуществления безопасной контролируемой генерической замены NTIDs. Результаты проведенной работы могут быть использованы в процессе дальнейшего усовершенствования и разработки новых аналитических методик ТЛМ вальпроевой кислоты, а также других NTIDs.Проведення ретельного терапевтичного лікарського моніторингу (ТЛМ) є актуальним при застосуванні лікарських препаратів з вузьким терапевтичним індексом (NTIDs), а також при здійсненні їх безпечної та контрольованої генеричної заміни. До цієї категорії належать антиепілептичні препарати, застосування яких пов’язане з ускладненим контролем ефективності та безпеки лікування. Одним з таких прикладів є вальпроєва кислота, терапевтичні концентрації якої значно варіюються в залежності від конкретного пацієнта. Необхідність здійснювати обґрунтований вибір та контроль індивідуального оптимального режиму дозування лікарських засобів, а також забезпечувати раціональне використання генеричних NTIDs зумовлюють актуальність впровадження ТЛМ у рутинну практику стандартизованої медичної допомоги окремим категоріям пацієнтів, що потребує відповідного науково-практичного підґрунтя.Мета дослідження. Надання науково-практичного обґрунтування процедури лікарського моніторингу шляхом валідації лабораторної методики визначення концентрації вальпроєвої кислоти у плазмі крові.Матеріали та методи. В процесі роботі були використані аналітичні, статистичні та біологічні методи. Вимірювання концентрації вальпроєвої кислоти в стандартних зразках плазми крові проводилося фотометричним методом з використанням реактивів виробництва SIEMENS, Inc., USA та контрольної сироватки «Хімічний контроль, рівень 1» виробництва Bio-Rad, Inc., USA. Вимірювання проводилися на автоматичному біохімічному аналізаторі Siemens Dimension RxL Max.Результати. Оцінка межі внутрішньолабораторної відтворюваності за фактором оператор-лаборант склала R = 3,25. Оцінка збіжності та відтворюваності методики за фактором часу та в різних діапазонах концентрацій показала відсутність грубих помилок у роботі аналізатора та статистично важливих відмінностей при проведенні вимірювань. Встановлено, що у діапазоні 73,8±110 мкг/мл значення концентрації вальпроєвої кислоти, визначені за допомогою досліджуваної методики на приладі Siemens Dimension RxL Max, можна вважати точними та достовірними. Також доведено лінійність даної методики у діапазоні вимірюваних концентрацій, що підтверджує можливість її використання для вимірювання концентрації вальпроєвої кислоти в плазмі крові.Висновки. Отримане науково-практичне підґрунтя є необхідним для належного впровадження процедури ТЛМ у процес надання стандартизованої медичної допомоги окремим категоріям пацієнтів з метою оптимізації індивідуального режиму дозування NTIDs. Окрім цього валідація методик ТЛМ дозволяє використовувати його для здійснення безпечної та контрольованої генеричної заміни NTIDs. Результати проведеної роботи можуть бути використані в процесі подальшого удосконалення та розробки нових аналітичних методик ТЛМ вальпроєвої кислоти, а також інших NTIDs.

    Валідація біохімічної методики визначення рівня загального холестерину у зразках біологічних рідин як основа забезпечення якості діагностики дисліпідемій

    Get PDF
    The main principles of creating a quality system in modern laboratory diagnostics are: standardization of laboratory processes by developing standard operating procedures; general quality management of laboratory research based on the development and implementation of the requirements of international standards (according to ISO 15189: 2015 "Medical laboratories. Basic requirements for quality and competence"); quality control of all stages of the laboratory process through the implementation of the validation procedure. Aim. To develop a methodology for conducting validation procedures to assess the suitability of a biochemical method for determining the level of total cholesterol in biological fluids in the Clinical Diagnostic Laboratory of the Clinical Diagnostic Center of the NUPh. Materials and methods. The object of the study was a standardized method for determining the concentration of total cholesterol. The method was validated using the “Cholesterol Reagent Set” test kit and the standard sample “Chemical control. Reagent kit. Level 1 ", manufactured by High Technology, Inc. (USA) with known concentration. The measurements were carried out on an Express Plus automatic biochemical analyzer manufactured by Bayer Corporation, Germany. When processing the research results, descriptive statistics were used and a number of statistical evaluations were carried out. Results. A protocol and a validation report were developed at the Clinical Diagnostic Laboratory of the CDC NUPh to assess the suitability of the method for determining the concentration of cholesterol in biological fluids by the photometric enzymatic method on an automatic biochemical analyzer Express Plus (using reagents and control material manufactured by High Technology, Inc., USA). The validation characteristics of the method were determined: repeatability and reproducibility, correctness and uncertainty of measurements. Evaluation of the internal laboratory repeatability and reproducibility of this technique indicates the absence of gross errors in the operation of the instrument and statistically important differences in measurements. The assessment of the correctness of the method (carried out using the control material) proved that the systematic error is not significant (according to a given acceptance criterion). The expanded uncertainty calculation showed that the obtained values ​​of the total cholesterol level can be considered accurate and reliable. Conclusions. Validation of the method for determining total cholesterol in human blood by the photometric enzymatic method has proven that this method has performance characteristics that correspond to the regulated ones, meets the established criteria, and the parameters measured with it correspond to the proper ones. Key words: validation, determination method, total cholesterol, repeatability and reproducibility, correctness and uncertainty of measurementsОсновными принципами создания системы качества в современной лабораторной диагностике являются: стандартизация лабораторных процессов путем разработки стандартных операционных процедур; общее управление качеством лабораторных исследований на основе разработки и выполнения требований международных стандартов (согласно ISO 15189:2015 «Лаборатории медицинские. Основные требования к качеству и компетентности»); контроль за качеством всех этапов лабораторного процесса через внедрение процедуры валидации. Цель. Разработка методики проведения валидационных процедур по оценке пригодности биохимической методики определения уровня общего холестерина в биологических жидкостях в Лаборатории клинической диагностики Клинико-диагностического центра НФаУ. Материалы и методы. Объектом исследования была стандартизированая методика определения концентрации общего холестерина. Валидацию методики проведено при использовании тест - набора «Cholesterol Reagent Set» и по стандартному образцу «Химический контроль. Набор реагентов. Уровень 1», производства High Technology, Inc. (США) с известной концентрацией. Измерения проводились на автоматическом биохимическом анализаторе Express Plus производства фирмы «Bayer Corporation», Германия. При обработке результатов исследований были использованы показатели описательной статистики и проведен ряд статистических оценок. Результаты. В Лаборатории клинической диагностики КДЦ НФаУ были разработаны протокол и валидационный отчет для оценки пригодности методики определения концентрации холестерина в биологических жидкостях фотометрическим ферментативным методом на автоматическом биохимическом анализаторе Еxpress Рlus (с помощью реагентов и контрольного материала производства High Technology, Inc., США). Были определены валидационные характеристики методики: сходимость и воспроизводимость, правильность и неопределенность измерений. Оценка внутреннелабораторной сходимости и воспроизводимости данной методики указывает на отсутствие грубых ошибок в работе прибора и статистически важных различий при проведении измерений. Оценка правильности методики (проводили с помощью контрольного материала) доказала, что систематическая погрешность не значима (по заданному критерию приемлемости). Расчет расширенной неопределенности показал, что полученные значения уровня общего холестерина можно считать точными и достоверными. Выводы. Валидация методики определения общего холестерина в крови человека фотометрическим ферментативным методом доказала, что данная методика имеет рабочие характеристики, которые соответствуют регламентированным, удовлетворяет установленным критериям, а измеренные с помощью нее параметры соответствуют должным. Ключевые слова: валидация, методика определения, общий холестерин, сходимость и воспроизводимость, правильность и неопределенность измеренийОсновними принципами створення системи якості у сучасній лабораторній діагностиці є: стандартизація лабораторних процесів через розробку стандартних операційних процедур; загальне управління якістю лабораторних досліджень на основі розробки та виконання вимог міжнародних стандартів (згідно ISO 15189:2015 «Лабораторії медичні. Основні вимоги до якості і компетентності»); контроль за якістю всіх етапів лабораторного процесу через впровадження процедури валідації. Мета. Розробка методики проведення валідаційних процедур з оцінки придатності біохімічної методики визначення рівня загального холестерину у біологічних рідинах у Лабораторії клінічної діагностики Клініко-діагностичного центру НФаУ. Матеріали та методи. Об’єктом дослідження була стандартизована методика визначення концентрації загального холестерину. Валідацію методики проведено при використанні тест – набору «Cholesterol Reagent Set» та за стандартним зразком «Хімічний контроль. Набір реагентів. Рівень 1», виробництва High Technology, Inc. (США) з відомою концентрацією. Вимірювання проводилися на автоматичному біохімічному аналізаторі Express Plus виробництва фірми «Bayer Corporation», Німеччина. При обробці результатів досліджень були використані показники описової статистики та проведено ряд статистичних оцінок. Результати. У Лабораторії клінічної діагностики КДЦ НФаУ були розроблені протокол та валідаційний звіт для оцінки придатності методики визначення концентрації холестерину в біологічних рідинах фотометричним ферментативним методом на автоматичному біохімічному аналізаторі Еxpress Рlus (за допомогою реагентів та контрольного матеріалу виробництва High Technology, Inc., США). Були визначені валідаційні характеристики методики: збіжність і відтворюваність, правильність та невизначеність вимірювань. Оцінка внутрішньо-лабораторної збіжності та відтворюваності даної методики вказує на відсутність грубих помилок в роботі приладу та статистично важливих відмінностей при проведені вимірювань. Оцінка правильності методики (проводили за допомогою контрольного матеріалу) довела, що систематична похибка не значима (по заданому критерію прийнятності). Розрахунок розширеної невизначеності показав, що отримані значення рівня загального холестерину можна вважати точними та достовірними. Висновки. Валідація методики визначення загального холестерину в крові людини фотометричним ферментативним методом довела, що дана методика має робочі характеристики, які відповідають регламентованим, задовольняє встановленим критеріям, а вимірюванні за допомогою неї параметри відповідають належним. Ключові слова: валідація, методика визначення, загальний холестерин, збіжність та відтворюваність, правильність та невизначеність вимірюван

    Впровадження системи якості згідно з державним стандартом ISO 15189:2015 у лабораторії клінічної діагностики Клініко-діагностичного центру Національного фармацевтичного університету: прикладні аспекти

    Get PDF
    One of the stages in development and implementation of the quality system in medical laboratories is to conduct the validation works. The main objects of these works are the methods by which measurements of various parameters inthe laboratory are carried out.Aim. To study the quality assurance aspects in the Laboratory of the Clinical Diagnostics of the Clinical and Diagnostic Center at the National University of Pharmacy (NPhU) by carrying out validation procedures to assess the intra-laboratory reproducibility of biochemical methods.Materials and methods. The objects of the study were standardized biochemical methods for determining the levels of gamma-glutamyltransferase (GGT) and alkaline phosphatase in the samples of biological fluids. The “Chemical control.A reagent kit” produced by High Technology, Inc. (USA) with the known concentration of analytes was selected as a control serum. The measurements were carried out using the Express Plus automatic biochemical analyzer manufactured by Bayer (Germany). When processing the results of the research the indicators of descriptive statistics were used, and statistical estimates were made.Results. The assessment of intralaboratory convergence and reproducibility of the methods for determining the concentration of GGT and alkaline phosphatase by the photometric method when working on the Express Plus biochemicalanalyzer carried out by two operators-laboratory technicians of the same qualification indicates the absence of gross errors in the analyzer operation and statistically significant differences in the measurements. The assessment of themethod correctness using the standard sample has proven that the systematic error is insignificant (according to the  criterion of acceptability specified). Thus, these methods provide the correctness of measurements within the laboratory. The increased uncertainty calculated as a metrological assessment of acceptability has shown that the values of the GGT and alkaline phosphatase levels obtained can be considered accurate and reliable.                            Conclusions. The validation of the methods for determination of GGT and alkaline phosphatase in the human blood by the photometric method has proven that these methods have performance characteristics corresponding to the regulated ones, satisfy the criteria specified, and the parameters measured with them correspond to the proper ones.Одним из этапов разработки и внедрения системы качества в медицинских лабораториях является проведение валидационных работ. Основными объектами этих работ становятся методики, с помощью которых проводятся измерения различных параметров в лаборатории.Цель. Исследование аспектов обеспечения качества в Лаборатории клинической диагностики Клинико-диагностического центра НФаУ путем проведения валидационных процедур по оценке внутрилабораторной вос-производимости биохимических методик.Материалы и методы. Объектами исследования стали стандартизированные биохимические методики определения уровней гамма-глутамилтрансферазы (ГГТ) и щелочной фосфатазы в образцах биологических жидкостей. В качестве контрольной сыворотки был выбран «Химический контроль. Набор реагентов» производства High Technology, Inc. (США) с известной концентрацией аналитов. Измерения проводились на автоматическом биохимическом анализаторе Express Plus фирмы Bayer (Германия). При обработке результатов исследований были использованы показатели описательной статистики и проведен ряд статистических оценок.Результаты. Оценка внутрилабораторной сходимости и воспроизводимости методик определения концентрации ГГТ и щелочной фосфатазы фотометрическим методом при работе на биохимическом анализаторе Еxpress Рlus, которая была проведена двумя операторами-лаборантами одинаковой квалификации, указывает на отсутствие грубых ошибок в работе анализатора и статистически важных различий при проведении измерений. Оценка правильности методик, проведенных с помощью стандартного образца доказала, что систематическая погрешность незначима (по заданному критерию приемлемости). Таким образом, данные методики обеспечивают правильность измерений в пределах лаборатории. Расширенная неопределенность, которая была рассчитана как метрологическая оценка приемлемости, показала, что полученные значения уровня ГГТ и щелочной фосфатазы можно считать точными и достоверными.Выводы. Валидация методик определения гамма-глутамилтрансферазы и щелочной фосфатазы в крови человека фотометрическим методом доказала, что данные методики имеют рабочие характеристики, которые соответствуют регламентированным, удовлетворяют установленным критериям, а измеренные с их помощью параметры соответствуют надлежащим.Одним з етапів розробки та впровадження системи якості у медичних лабораторіях є проведення валідаційних робіт. Основними об’єктами цих робіт стають методики, за допомогою яких проводяться вимірювання різних параметрів у лабораторії.Мета. Дослідження аспектів забезпечення якості у Лабораторії клінічної діагностики Клініко-діагностичного центру НФаУ шляхом проведення валідаційних процедур з оцінки придатності біохімічних методик.Матеріали та методи. Об’єктами дослідження стали стандартизовані біохімічні методики визначення рівнів гамма-глутамілтрансферази (ГГТ) та лужної фосфатази у зразках біологічних рідин. У якості контрольної сироватки був обраний «Хімічний контроль. Набір реагентів» виробництва High Technology, Inc. (США) з відомою концентрацією аналітів. Вимірювання проводилися на автоматичному біохімічному аналізаторі Express Plus фірми Bayer (Німеччина). При обробці результатів досліджень були використані показники описової статистики та проведений ряд статистичних оцінок.Результати. Оцінка внутрішньолабораторної збіжності та відтворюваності методик визначення концентрації ГГТ та лужної фосфатази фотометричним методом при роботі на аналізаторі біохімічному Еxpress Рlus, проведена двома операторами-лаборантами однакової кваліфікації, вказує на відсутність грубих помилок у роботі аналізатора та статистично важливих відмінностей при проведенні вимірювань. Оцінка правильності методик, проведених за допомогою стандартного зразка, довела, що систематична похибка не значима (по заданому критерію прийнятності). Отже, дані методики забезпечують правильність вимірів у межах лабораторії. Розширена невизначеність, яка була розрахована як метрологічна оцінка придатності, показала, що отримані значення рівня ГГТ та лужної фосфатази можна вважати точними та достовірними.Висновки. Валідація методик визначення гамма-глутамілтрансферази та лужної фосфатази в крові людини фотометричним методом довела, що дані методики мають робочі характеристики, які відповідають регламентованим, задовольняють встановленим критеріям, а вимірювані за допомогою них параметри відповідають належним

    Підходи до впровадження системи якості згідно з ISO 15189:2015 у Лабораторії клінічної діагностики Клініко-діагностичного центру Національного фармацевтичного університету на прикладі методик визначення рівнів лактатдегідрогенази та глюкози у біологічних

    Get PDF
    A modern clinical and diagnostic laboratory should solve the problems of implementing and maintaining the quality system based on the application of the principles of the specialized standard ISO 15189: 2015 “Medical laboratories. Some requirements for quality and competence” as an element of providing the procedure for assessing the conformity of the laboratory research results. The effective solution of these issues becomes one of the important conditions for accreditation, and the introduction of the assessment of the suitability of methods in daily activities is evidence of the competence of modern clinical and diagnostic laboratories.Aim. To study the approaches to quality assurance in the Clinical Diagnostics Laboratory of the Clinical Diagnostic Center at the NUPh by carrying out validation procedures for assessing the suitability of biochemical methods for determining levels of lactate dehydrogenase (LDH) and glucose in biological fluids.Materials and methods. The objects of the study were standardized biochemical methods for determining levels of LDH and glucose. “Chemical control. Reagent kit. Level1” produced by High Technology, Inc. (USA) with the known concentration of analytes was selected as a control serum. The measurements were performed on an Express Express Plus automatic biochemical analyzer manufactured by Bayer Corporation,Germany. When processing the research results the indicators of descriptive statistics were used, and a number of statistical evaluations were carried out.Results. The procedure for validation of methods consisted of several stages. Protocols and validation reports were developed at the premises of the Clinical Diagnostics Laboratory of theClinicalDiagnosticCenter at the NUPh to assess the suitability of methods for determining LDH and glucose in biological fluids by the photometric method using an Еxpress Рlus biochemical analyzer. Validation was performed using reagents manufactured by High Technology, Inc. (USA) and control materials (standard samples). The following validation characteristics of the methods were determined: specificity, convergence and reproducibility, accuracy, measurement uncertainty. Assessment of the internal laboratory convergence and reproducibility of methods for determining the concentration of LDH and glucose during the operation of the analyzer, which was carried out by two laboratory operators of the same qualification, indicated the absence of gross errors in the operation of the analyzer and statistically important differences in the measurements. Assessment of the correctness of the methods performed using the control serum proved that the systematic error was not significant (according to the given acceptance criterion). Thus, these methods provided correct measurements within the laboratory. The calculation of the expanded uncertainty showed that the values of LDH and glucose levels obtained could be considered accurate and reliable.Conclusions. Validation of methods for determining lactate dehydrogenase and glucose in the human blood by the photometric method has proven that these methods have performance characteristics that meet the regulated and established criteria, and the parameters measured with their help correspond to the proper ones. Современная клинико-диагностическая лаборатория должна решать проблемы внедрения и обеспечения системы качества, основанной на применении принципов специализированного стандарта ISO 15189:2015 «Лаборатории медицинские. Отдельные требования к качеству и компетентности» как элемента обеспечения процедуры оценки соответствия результатов лабораторных исследований. Эффективное решение этих вопросов становится одним из важных условий при аккредитации, а внедрение оценки пригодности методов в повседневную деятельность является свидетельством компетентности современных клинико-диагностических лабораторий.Цель. Исследование подходов к обеспечению качества в Лаборатории клинической диагностики Клинико-диагностического центра НФаУ посредством проведения валидационных процедур по оценке пригодности биохимических методик определения уровней лактатдегидрогеназы (ЛДГ) и глюкозы в биологических жидкостях.Материалы и методы. Объектами исследования стали стандартизированные биохимические методики определения уровней ЛДГ и глюкозы. В качестве контрольной сыворотки был выбран «Химический контроль. Набор реагентов. Уровень 1» производства High Technology, Inc. (США) с известной концентрацией аналитов. Измерения проводились на автоматическом биохимическом анализаторе Express Plus производства фирмы «Bayer Corporation», Германия. При обработке результатов исследований были использованы показатели описательной статистики и проведен ряд статистических оценок.Результаты. Процедура валидации методик состоит из нескольких этапов. На базе Лаборатории клинической диагностики КДЦ НФаУ были разработаны протоколы и валидационные отчеты для оценки пригодности методик определения ЛДГ и глюкозы в биологических жидкостях фотометрическим методом с помощью биохимического анализатора Еxpress Рlus. Валидацию было проведено с помощью реагентов производства High Technology, Inc., USA и контрольных материалов (стандартных образцов). Были определены валидационные характеристики методик: специфичность, сходимость и воспроизводимость, правильность, неопределенность измерений. Оценка внутренне-лабораторной сходимости и воспроизводимости методик определения концентрации ЛДГ и глюкозы при работе анализатора, которая была проведена двумя операторами-лаборантами одинаковой квалификации, указывает на отсутствие грубых ошибок в работе анализатора и статистически важных различий при проведении измерений. Оценка правильности методик с использованием контрольной сыворотки доказала, что систематическая погрешность не значима (по заданному критерию приемлемости). Таким образом, данные методики обеспечивают правильность измерений в пределах лаборатории. Расчет расширенной неопределенности показал, что полученные значения уровней ЛДГ и глюкозы можно считать точными и достоверными.Выводы. Валидация методик определения лактатдегидрогеназы и глюкозы в крови человека фотометрическим методом доказала, что данные методики имеют рабочие характеристики, которые соответствуют регламентированным, удовлетворяют установленным критериям, а измеренные с их помощью параметры соответствуют надлежащим. Сучасна клініко-діагностична лабораторія повинна вирішувати проблеми впровадження та забезпечення системи якості, заснованої на застосуванні принципів спеціалізованого стандарту ISO 15189:2015 «Лабораторії медичні. Окремі вимоги до якості та компетентності» як елементу забезпечення процедури оцінки відповідності результатів лабораторних досліджень. Ефективне вирішення цих питань стає однією з важливих умов при акредитації, а впровадження оцінювання придатності методів у повсякденну діяльність є свідченням компетентності сучасних клініко-діагностичних лабораторій.Мета. Дослідження підходів до забезпечення якості у Лабораторії клінічної діагностики Клініко-діагностичного центру НФаУ за допомогою проведення валідаційних процедур з оцінки придатності біохімічних методик визначення рівнів лактатдегідрогенази (ЛДГ) та глюкози у біологічних рідинах.Матеріали та методи. Об’єктами дослідження стали стандартизовані біохімічні методики визначення рівнів ЛДГ та глюкози. В якості контрольної сироватки був обраний «Хімічний контроль. Набір реагентів. Рівень 1», виробництва High Technology, Inc. (США) з відомою концентрацією аналітів. Вимірювання проводилися на автоматичному біохімічному аналізаторі Express Plus виробництва фірми «Bayer Corporation», Німеччина. При обробці результатів досліджень були використані показники описової статистики та проведено ряд статистичних оцінок.Результати. Процедура валідації методик складається з кількох етапів. На базі Лабораторії клінічної діагностики КДЦ НФаУ були розроблені протоколи та валідаційні звіти для оцінки придатності методик визначення ЛДГ та глюкози в біологічних рідинах фотометричним методом за допомогою біохімічного аналізатора Еxpress Рlus. Валідацію було проведено за допомогою реагентів виробництва High Technology, Inc.,USA та контрольних матеріалів (стандартних зразків). Були визначені валідаційні характеристики методик: специфічність, збіжність та відтворюваність, правильність, невизначеність вимірювань. Оцінка внутрішньо-лабораторної збіжності та відтворюваності методик визначення концентрації ЛДГ та глюкози при роботі аналізаторі, яка була проведена двома операторами-лаборантами однакової кваліфікації, вказує на відсутність грубих помилок у роботі аналізатора та статистично важливих відмінностей при проведенні вимірювань. Оцінка правильності методик, проведених за допомогою контрольної сироватки, довела, що систематична похибка не значима (по заданому критерію прийнятності). Отже, дані методики забезпечують правильність вимірів у межах лабораторії. Розрахунок розширеної невизначеності показав, що отримані значення рівнів ЛДГ та глюкози можна вважати точними та достовірними.Висновки. Валідація методик визначення лактатдегідрогенази та глюкози в крові людини фотометричним методом довела, що дані методики мають робочі характеристики, які відповідають регламентованим, задовольняють встановленим критеріям, а вимірювані за допомогою них параметри відповідають належним

    Впровадження системи якості згідно з державним стандартом ISO 15189:2015 у лабораторії клінічної діагностики Клініко-діагностичного центру Національного фармацевтичного університету: прикладні аспекти

    No full text
    One of the stages in development and implementation of the quality system in medical laboratories is to conduct the validation works. The main objects of these works are the methods by which measurements of various parameters inthe laboratory are carried out.Aim. To study the quality assurance aspects in the Laboratory of the Clinical Diagnostics of the Clinical and Diagnostic Center at the National University of Pharmacy (NPhU) by carrying out validation procedures to assess the intra-laboratory reproducibility of biochemical methods.Materials and methods. The objects of the study were standardized biochemical methods for determining the levels of gamma-glutamyltransferase (GGT) and alkaline phosphatase in the samples of biological fluids. The “Chemical control.A reagent kit” produced by High Technology, Inc. (USA) with the known concentration of analytes was selected as a control serum. The measurements were carried out using the Express Plus automatic biochemical analyzer manufactured by Bayer (Germany). When processing the results of the research the indicators of descriptive statistics were used, and statistical estimates were made.Results. The assessment of intralaboratory convergence and reproducibility of the methods for determining the concentration of GGT and alkaline phosphatase by the photometric method when working on the Express Plus biochemicalanalyzer carried out by two operators-laboratory technicians of the same qualification indicates the absence of gross errors in the analyzer operation and statistically significant differences in the measurements. The assessment of themethod correctness using the standard sample has proven that the systematic error is insignificant (according to the  criterion of acceptability specified). Thus, these methods provide the correctness of measurements within the laboratory. The increased uncertainty calculated as a metrological assessment of acceptability has shown that the values of the GGT and alkaline phosphatase levels obtained can be considered accurate and reliable.                            Conclusions. The validation of the methods for determination of GGT and alkaline phosphatase in the human blood by the photometric method has proven that these methods have performance characteristics corresponding to the regulated ones, satisfy the criteria specified, and the parameters measured with them correspond to the proper ones.Одним из этапов разработки и внедрения системы качества в медицинских лабораториях является проведение валидационных работ. Основными объектами этих работ становятся методики, с помощью которых проводятся измерения различных параметров в лаборатории.Цель. Исследование аспектов обеспечения качества в Лаборатории клинической диагностики Клинико-диагностического центра НФаУ путем проведения валидационных процедур по оценке внутрилабораторной вос-производимости биохимических методик.Материалы и методы. Объектами исследования стали стандартизированные биохимические методики определения уровней гамма-глутамилтрансферазы (ГГТ) и щелочной фосфатазы в образцах биологических жидкостей. В качестве контрольной сыворотки был выбран «Химический контроль. Набор реагентов» производства High Technology, Inc. (США) с известной концентрацией аналитов. Измерения проводились на автоматическом биохимическом анализаторе Express Plus фирмы Bayer (Германия). При обработке результатов исследований были использованы показатели описательной статистики и проведен ряд статистических оценок.Результаты. Оценка внутрилабораторной сходимости и воспроизводимости методик определения концентрации ГГТ и щелочной фосфатазы фотометрическим методом при работе на биохимическом анализаторе Еxpress Рlus, которая была проведена двумя операторами-лаборантами одинаковой квалификации, указывает на отсутствие грубых ошибок в работе анализатора и статистически важных различий при проведении измерений. Оценка правильности методик, проведенных с помощью стандартного образца доказала, что систематическая погрешность незначима (по заданному критерию приемлемости). Таким образом, данные методики обеспечивают правильность измерений в пределах лаборатории. Расширенная неопределенность, которая была рассчитана как метрологическая оценка приемлемости, показала, что полученные значения уровня ГГТ и щелочной фосфатазы можно считать точными и достоверными.Выводы. Валидация методик определения гамма-глутамилтрансферазы и щелочной фосфатазы в крови человека фотометрическим методом доказала, что данные методики имеют рабочие характеристики, которые соответствуют регламентированным, удовлетворяют установленным критериям, а измеренные с их помощью параметры соответствуют надлежащим.Одним з етапів розробки та впровадження системи якості у медичних лабораторіях є проведення валідаційних робіт. Основними об’єктами цих робіт стають методики, за допомогою яких проводяться вимірювання різних параметрів у лабораторії.Мета. Дослідження аспектів забезпечення якості у Лабораторії клінічної діагностики Клініко-діагностичного центру НФаУ шляхом проведення валідаційних процедур з оцінки придатності біохімічних методик.Матеріали та методи. Об’єктами дослідження стали стандартизовані біохімічні методики визначення рівнів гамма-глутамілтрансферази (ГГТ) та лужної фосфатази у зразках біологічних рідин. У якості контрольної сироватки був обраний «Хімічний контроль. Набір реагентів» виробництва High Technology, Inc. (США) з відомою концентрацією аналітів. Вимірювання проводилися на автоматичному біохімічному аналізаторі Express Plus фірми Bayer (Німеччина). При обробці результатів досліджень були використані показники описової статистики та проведений ряд статистичних оцінок.Результати. Оцінка внутрішньолабораторної збіжності та відтворюваності методик визначення концентрації ГГТ та лужної фосфатази фотометричним методом при роботі на аналізаторі біохімічному Еxpress Рlus, проведена двома операторами-лаборантами однакової кваліфікації, вказує на відсутність грубих помилок у роботі аналізатора та статистично важливих відмінностей при проведенні вимірювань. Оцінка правильності методик, проведених за допомогою стандартного зразка, довела, що систематична похибка не значима (по заданому критерію прийнятності). Отже, дані методики забезпечують правильність вимірів у межах лабораторії. Розширена невизначеність, яка була розрахована як метрологічна оцінка придатності, показала, що отримані значення рівня ГГТ та лужної фосфатази можна вважати точними та достовірними.Висновки. Валідація методик визначення гамма-глутамілтрансферази та лужної фосфатази в крові людини фотометричним методом довела, що дані методики мають робочі характеристики, які відповідають регламентованим, задовольняють встановленим критеріям, а вимірювані за допомогою них параметри відповідають належним

    Steric relations in diene condensations of cyclopentadiene with monosubstituted ethylenes

    Get PDF
    1. The reactions of cyclopentadiene with vinyl chloride and with vinyl acetate give, in the first place, the kinetically favored endo adducts, which are then converted into their thermodynamically stable isomers. 2. For vinyl chloride the exo adduct is the stable form. 3. 11-Bromo-9,10-dihydro-9,10-ethanoanthracene, 9,10-dihydro-9,10-ethanoanthracen-11-ol, and the cyclopentadiene diadduct of vinyl bromide were synthesized. 4. The dipole moments of the compounds synthesized and of some previously described compounds were measured. © 1966 Consultants Bureau Enterprises, Inc

    Підходи до впровадження системи якості згідно з ISO 15189:2015 у Лабораторії клінічної діагностики Клініко-діагностичного центру Національного фармацевтичного університету на прикладі методик визначення рівнів лактатдегідрогенази та глюкози у біологічних

    No full text
    A modern clinical and diagnostic laboratory should solve the problems of implementing and maintaining the quality system based on the application of the principles of the specialized standard ISO 15189: 2015 “Medical laboratories. Some requirements for quality and competence” as an element of providing the procedure for assessing the conformity of the laboratory research results. The effective solution of these issues becomes one of the important conditions for accreditation, and the introduction of the assessment of the suitability of methods in daily activities is evidence of the competence of modern clinical and diagnostic laboratories.Aim. To study the approaches to quality assurance in the Clinical Diagnostics Laboratory of the Clinical Diagnostic Center at the NUPh by carrying out validation procedures for assessing the suitability of biochemical methods for determining levels of lactate dehydrogenase (LDH) and glucose in biological fluids.Materials and methods. The objects of the study were standardized biochemical methods for determining levels of LDH and glucose. “Chemical control. Reagent kit. Level1” produced by High Technology, Inc. (USA) with the known concentration of analytes was selected as a control serum. The measurements were performed on an Express Express Plus automatic biochemical analyzer manufactured by Bayer Corporation,Germany. When processing the research results the indicators of descriptive statistics were used, and a number of statistical evaluations were carried out.Results. The procedure for validation of methods consisted of several stages. Protocols and validation reports were developed at the premises of the Clinical Diagnostics Laboratory of theClinicalDiagnosticCenter at the NUPh to assess the suitability of methods for determining LDH and glucose in biological fluids by the photometric method using an Еxpress Рlus biochemical analyzer. Validation was performed using reagents manufactured by High Technology, Inc. (USA) and control materials (standard samples). The following validation characteristics of the methods were determined: specificity, convergence and reproducibility, accuracy, measurement uncertainty. Assessment of the internal laboratory convergence and reproducibility of methods for determining the concentration of LDH and glucose during the operation of the analyzer, which was carried out by two laboratory operators of the same qualification, indicated the absence of gross errors in the operation of the analyzer and statistically important differences in the measurements. Assessment of the correctness of the methods performed using the control serum proved that the systematic error was not significant (according to the given acceptance criterion). Thus, these methods provided correct measurements within the laboratory. The calculation of the expanded uncertainty showed that the values of LDH and glucose levels obtained could be considered accurate and reliable.Conclusions. Validation of methods for determining lactate dehydrogenase and glucose in the human blood by the photometric method has proven that these methods have performance characteristics that meet the regulated and established criteria, and the parameters measured with their help correspond to the proper ones. Современная клинико-диагностическая лаборатория должна решать проблемы внедрения и обеспечения системы качества, основанной на применении принципов специализированного стандарта ISO 15189:2015 «Лаборатории медицинские. Отдельные требования к качеству и компетентности» как элемента обеспечения процедуры оценки соответствия результатов лабораторных исследований. Эффективное решение этих вопросов становится одним из важных условий при аккредитации, а внедрение оценки пригодности методов в повседневную деятельность является свидетельством компетентности современных клинико-диагностических лабораторий.Цель. Исследование подходов к обеспечению качества в Лаборатории клинической диагностики Клинико-диагностического центра НФаУ посредством проведения валидационных процедур по оценке пригодности биохимических методик определения уровней лактатдегидрогеназы (ЛДГ) и глюкозы в биологических жидкостях.Материалы и методы. Объектами исследования стали стандартизированные биохимические методики определения уровней ЛДГ и глюкозы. В качестве контрольной сыворотки был выбран «Химический контроль. Набор реагентов. Уровень 1» производства High Technology, Inc. (США) с известной концентрацией аналитов. Измерения проводились на автоматическом биохимическом анализаторе Express Plus производства фирмы «Bayer Corporation», Германия. При обработке результатов исследований были использованы показатели описательной статистики и проведен ряд статистических оценок.Результаты. Процедура валидации методик состоит из нескольких этапов. На базе Лаборатории клинической диагностики КДЦ НФаУ были разработаны протоколы и валидационные отчеты для оценки пригодности методик определения ЛДГ и глюкозы в биологических жидкостях фотометрическим методом с помощью биохимического анализатора Еxpress Рlus. Валидацию было проведено с помощью реагентов производства High Technology, Inc., USA и контрольных материалов (стандартных образцов). Были определены валидационные характеристики методик: специфичность, сходимость и воспроизводимость, правильность, неопределенность измерений. Оценка внутренне-лабораторной сходимости и воспроизводимости методик определения концентрации ЛДГ и глюкозы при работе анализатора, которая была проведена двумя операторами-лаборантами одинаковой квалификации, указывает на отсутствие грубых ошибок в работе анализатора и статистически важных различий при проведении измерений. Оценка правильности методик с использованием контрольной сыворотки доказала, что систематическая погрешность не значима (по заданному критерию приемлемости). Таким образом, данные методики обеспечивают правильность измерений в пределах лаборатории. Расчет расширенной неопределенности показал, что полученные значения уровней ЛДГ и глюкозы можно считать точными и достоверными.Выводы. Валидация методик определения лактатдегидрогеназы и глюкозы в крови человека фотометрическим методом доказала, что данные методики имеют рабочие характеристики, которые соответствуют регламентированным, удовлетворяют установленным критериям, а измеренные с их помощью параметры соответствуют надлежащим. Сучасна клініко-діагностична лабораторія повинна вирішувати проблеми впровадження та забезпечення системи якості, заснованої на застосуванні принципів спеціалізованого стандарту ISO 15189:2015 «Лабораторії медичні. Окремі вимоги до якості та компетентності» як елементу забезпечення процедури оцінки відповідності результатів лабораторних досліджень. Ефективне вирішення цих питань стає однією з важливих умов при акредитації, а впровадження оцінювання придатності методів у повсякденну діяльність є свідченням компетентності сучасних клініко-діагностичних лабораторій.Мета. Дослідження підходів до забезпечення якості у Лабораторії клінічної діагностики Клініко-діагностичного центру НФаУ за допомогою проведення валідаційних процедур з оцінки придатності біохімічних методик визначення рівнів лактатдегідрогенази (ЛДГ) та глюкози у біологічних рідинах.Матеріали та методи. Об’єктами дослідження стали стандартизовані біохімічні методики визначення рівнів ЛДГ та глюкози. В якості контрольної сироватки був обраний «Хімічний контроль. Набір реагентів. Рівень 1», виробництва High Technology, Inc. (США) з відомою концентрацією аналітів. Вимірювання проводилися на автоматичному біохімічному аналізаторі Express Plus виробництва фірми «Bayer Corporation», Німеччина. При обробці результатів досліджень були використані показники описової статистики та проведено ряд статистичних оцінок.Результати. Процедура валідації методик складається з кількох етапів. На базі Лабораторії клінічної діагностики КДЦ НФаУ були розроблені протоколи та валідаційні звіти для оцінки придатності методик визначення ЛДГ та глюкози в біологічних рідинах фотометричним методом за допомогою біохімічного аналізатора Еxpress Рlus. Валідацію було проведено за допомогою реагентів виробництва High Technology, Inc.,USA та контрольних матеріалів (стандартних зразків). Були визначені валідаційні характеристики методик: специфічність, збіжність та відтворюваність, правильність, невизначеність вимірювань. Оцінка внутрішньо-лабораторної збіжності та відтворюваності методик визначення концентрації ЛДГ та глюкози при роботі аналізаторі, яка була проведена двома операторами-лаборантами однакової кваліфікації, вказує на відсутність грубих помилок у роботі аналізатора та статистично важливих відмінностей при проведенні вимірювань. Оцінка правильності методик, проведених за допомогою контрольної сироватки, довела, що систематична похибка не значима (по заданому критерію прийнятності). Отже, дані методики забезпечують правильність вимірів у межах лабораторії. Розрахунок розширеної невизначеності показав, що отримані значення рівнів ЛДГ та глюкози можна вважати точними та достовірними.Висновки. Валідація методик визначення лактатдегідрогенази та глюкози в крові людини фотометричним методом довела, що дані методики мають робочі характеристики, які відповідають регламентованим, задовольняють встановленим критеріям, а вимірювані за допомогою них параметри відповідають належним