13 research outputs found

    The use of cyclodextrin template-based metal oxide nanomaterials in the development of electrochemical sensors for phenolic endocrine disruptor compounds

    Get PDF
    Magister Scientiae - MScIron oxide nanoparticles were prepared using co-precipitation method in the presence and absence of beta-cyclodextrin β-CD). Such materials were characterized using transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared (ATR-FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). The TEM shows that the surface morphology has no difference between nanoparticles prepared in the presence and absence of beta-cyclodextrin β-CD), amorphous particles with high surface area and dimensions of about 100 nm by 500 nm. The amorphous states of nanoparticles are confirmed further by XRD. The ATR-FTIR analysis confirms inclusion complex between β-CD and nanoparticles. The nanoparticles synthesized were used to develop an electrochemical sensor for phenolic endocrine disruptors by modifying the surface area of glassy carbon electrode (GCE). Electrochemical characterization of the iron oxide β-CD nano-composites, studied in 0.1 M potassium chloride (KCl) using chronoamperometry,showed that the surface concentration of the adsorbed composite material was 8.5 x 10-8 mol/cm2. Sensor analysis of bisphenol A (BPA) was carried out using cyclic voltammetry (CV) and square wave voltammetry (SWV) based on amperometric techniques which gave a linear range of 0.50 × 10-6 M to 50 × 10-6 M; limit of detection of 0.156 x 10-6 M and order of magnitude of linearity of 2.03. Hence, the sensor was further used to study 4-tert-octylphenol (TOP); the results showed that the sensitivity and the limit of detection were 11.31 nA L/mol and 0.249 x 10-6 M, respectively and order of magnitude of linearity of 2.00.South Afric

    A fumonisins immunosensor based on polyanilino-carbon nanotubes doped with palladium telluride quantum dots

    Get PDF
    An impedimetric immunosensor for fumonisins was developed based on poly(2,5-dimethoxyaniline)-multi-wall carbon nanotubes doped with palladium telluride quantum dots onto a glassy carbon surface. The composite was assembled by a layer-by-layer method to form a multilayer film of quantum dots (QDs) and poly(2,5-dimethoxyaniline)- multi-wall carbon nanotubes (PDMA-MWCNT). Preparation of the electrochemical immunosensor for fumonisins involved drop-coating of fumonisins antibody onto the composite modified glassy carbon electrode. The electrochemical impedance spectroscopy response of the FB1 immunosensor (GCE/PT-PDMA-MWCNT/anti-Fms-BSA) gave a linear range of 7 to 49 ng L−1 and the corresponding sensitivity and detection limits were 0.0162 kΩ L ng−1 and 0.46 pg L−1 , respectively, hence the limit of detection of the GCE/PT-PDMA-MWCNT immunosensor for fumonisins in corn certified material was calculated to be 0.014 and 0.011 ppm for FB1, and FB2 and FB3, respectively. These results are lower than those obtained by ELISA, a provisional maximum tolerable daily intake (PMTDI) for fumonisins (the sum of FB1, FB2, and FB3) established by the Joint FAO/WHO expert committee on food additives and contaminants of 2 μg kg−1 and the maximum level recommended by the U.S. Food and Drug Administration (FDA) for protection of human consumption (2–4 mg L−1 )

    Development of Impedimetric Immunosensor for Fumonisin on Polyanilino-Carbon Nanotubes Doped with Palladium Telluride Nanocrystals

    Get PDF
    Philosophiae Doctor - PhDImmunosensors are affinity ligand-based biosensor solid-state devices in which the immunochemical reaction is coupled to a transducer. The specificity of the molecular recognition of antigens by antibodies to form a stable complex is the basis of the immunosensor on the electrode. The development of such a sensor requires a better design and preparation of an optimum interface between the biomolecules and the detector material. The immunosensors were developed based on Polyaniline derivative composite. Novel water soluble PdTe quantum dots (QD) was synthesized and characterized by different physical techniques such as UV-Visible (UV-VIS), Fluorescence Spectroscopy (PL), Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and X-Ray Diffraction (XRD). The electroactivity of such synthesized quantum dots was studied by cyclic voltammetry in aqueous media. The synthesis of poly(2,5- dimethoxyaniline)-multi wall 'carbon nanotubes nanocomposite was carried out by electropolymerization in situ of 2,5-dimethoxyaniline - multi wall carbon nanotubes (PDMA-MWCNT) from aqueous dispersion containing acid-treated multi wall carbon nanotubes (MWCNT) and 2,5-dimethoxyaniline subsequently modifying a glassy carbon electrode in acid media. An undoped PDMA was also prepared for control. The composite for this work, consists of layer-by-layer method to form a multilayer film of QDs and PDMA-MWCNT. The method used was as follows; the drop coating of quantum dots followed by electrodeposition of poly(2,5- dimethoxyaniline )-carbon nanotubes onto surface of glassy carbon. The PDMA-CNT was characterized by UV-Visible (UV-Vis), Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy (SEM). The electrochemical characterisation of PDMA-CNT was carried out using cyclic voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). The composite (QDs-PDMA-MWCNT) was also characterized using above mentioned techniques. The electrochemical immunosensor for fumonisin a mycotoxin was prepared by dropcoating of mycotoxins antibody onto the composite modified glassy carbon electrode. The response profiles of fumonisins sensors system were obtained from electrochemical impedance spectroscopy (EIS) measurements. The fumonisin immunosensor was used for the detection of fumonisins in certified com reference materials. For comparison reasons, analysis of such mycotoxins was carried out by using conventional analytical method enzyme-linked immunosorbent assay (ELISA). The EIS response of FBI immunosensor (GCEIPT-PDMA-MWCNT/anti-Fms-BSA) gave a linear range of 7 to 49 ng L-I and the corresponding sensitivity and detection limits were 0.0162 ka L ng-I and 0.46 pg L-I, respectively. Hence the limit of detection of GCEIPT-PDMA-MWCNT immunosensor for fumonisins in com certified material was calculated to 0.014 and 0.011 ppm for FBI, and FB2 and FB3, respectively. These results are lower than those obtained by ELISA, a provisional maximum tolerable daily intake (PMTDI) for fumonisins (the sum of FBI, FB2, and FB3) established by the Joint FAO / WHO expert committee on food additives and contaminants of 2 ug kg" and the maximum level recommended by the U.S. Food and Drug Administration (FDA) for protection of human consumption (2-4 mg L-I)

    Electronics of Anion Hot Injection-Synthesized Te-Functionalized Kesterite Nanomaterial

    No full text
    Metal chalcogenides such as copper zinc tin sulfide (CZTS) have been intensively studied as potential photovoltaic cell materials, but their viability have been marred by crystal defects and low open circuit potential (Voc) deficit, which affected their energy conversion efficiency. Strategies to improve on the properties of this material such as alloying with other elements have been explored and have yielded promising results. Here, we report the synthesis of CZTS and the partial substitution of S with Te via anion hot injection synthesis method to form a solid solution of a novel kesterite nanomaterial, namely, copper zinc tin sulfide telluride (CZTSTe). Particle-size analyzed via small angle X-ray scattering spectroscopy (SAXS) confirmed that CZTS and CZTSTe materials are nanostructured. Crystal planes values of 112, 200, 220 and 312 corresponding to the kesterite phase with tetragonal modification were revealed by the X-ray diffraction (XRD) spectroscopic analysis of CZTS and CZTSTe. The Raman spectroscopy confirmed the shifts at 281 cm−1 and 347 cm−1 for CZTS, and 124 cm−1, 149 cm−1 and 318 cm−1 for CZTSTe. High degradation rate and the production of hot electrons are very detrimental to the lifespan of photovoltaic cell (PVC) devices, and thus it is important to have PVC absorber layer materials that are thermally stable. Thermogravimetric analysis (TGA) analysis indicated a 10% improvement in the thermal stability of CZTSTe compared to CZTS at 650 °C. With improved electrical conductivity, low charge transfer resistance (Rct) and absorption in the visible region with a low bandgap energy (Eg) of 1.54 eV, the novel CZTSTe nanomaterials displayed favorable properties for photovoltaics application

    Application on Gold Nanoparticles-Dotted 4-Nitrophenylazo Graphene in a Label-Free Impedimetric Deoxynivalenol Immunosensor

    No full text
    In this paper, we report a new concept to construct a label-free electrochemical inhibition-based immunosensor for the detection of the mycotoxin deoxynivalenol (DON) in cereal samples. The electrochemical impedance spectroscopy of tris(bipyridine) ruthenium (II) chloride was used as a marker enhanced with gold nanoparticles-dotted 4-nitrophenylazo functionalized graphene (AuNp/G/PhNO2) nanocatalyst mediated in Nafion on a glassy carbon electrode. Under the optimized conditions, the formation of immunocomplexes inhibited electron flow and increased the charge transfer resistance of the sensing interface linearly. The change in impedance was proportional to DON concentrations in the range of 6–30 ng/mL with a sensitivity and detection limit of 32.14 ΩL/ng and 0.3 µg/mL, respectively, which compares favorably with the ELISA result. The proposed sensor had a stability of 80.3%, good precision and selectivity in DON standard solution containing different interfering agents, indicating promising application prospect for this strategy in designing impedimetric, electrochemiluminescent, voltammetric or amperometric sensors

    Graphene Oxide Decorated Nanometal-Poly(Anilino-Dodecylbenzene Sulfonic Acid) for Application in High Performance Supercapacitors

    No full text
    Graphene oxide (GO) decorated with silver (Ag), copper (Cu) or platinum (Pt) nanoparticles that are anchored on dodecylbenzene sulfonic acid (DBSA)-doped polyaniline (PANI) were prepared by a simple one-step method and applied as novel materials for high performance supercapacitors. High-resolution transmission electron microscopy (HRTEM) and high-resolution scanning electron microscopy (HRSEM) analyses revealed that a metal-decorated polymer matrix is embedded within the GO sheet. This caused the M/DBSA⁻PANI (M = Ag, Cu or Pt) particles to adsorb on the surface of the GO sheets, appearing as aggregated dark regions in the HRSEM images. The Fourier transform infrared (FTIR) spectroscopy studies revealed that GO was successfully produced and decorated with Ag, Cu or Pt nanoparticles anchored on DBSA⁻PANI. This was confirmed by the appearance of the GO signature epoxy C⁻O vibration band at 1040 cm−1 (which decreased upon the introduction of metal nanoparticle) and the PANI characteristic N⁻H stretching vibration band at 3144 cm−1 present only in the GO/M/DBSA⁻PANI systems. The composites were tested for their suitability as supercapacitor materials; and specific capacitance values of 206.4, 192.8 and 227.2 F·g−1 were determined for GO/Ag/DBSA⁻PANI, GO/Cu/DBSA⁻PANI and GO/Pt/DBSA⁻PANI, respectively. The GO/Pt/DBSA⁻PANI electrode exhibited the best specific capacitance value of the three electrodes and also had twice the specific capacitance value reported for Graphene/MnO2//ACN (113.5 F·g−1). This makes GO/Pt/DBSA⁻PANI a very promising organic supercapacitor material

    Electrochemical Aptatoxisensor Responses on Nanocomposites Containing Electro-Deposited Silver Nanoparticles on Poly(Propyleneimine) Dendrimer for the Detection of Microcystin-LR in Freshwater

    No full text
    A sensitive and reagentless electrochemical aptatoxisensor was developed on cobalt (II) salicylaldiimine metallodendrimer (SDD–Co(II)) doped with electro-synthesized silver nanoparticles (AgNPs) for microcystin-LR (L, l-leucine; R, l-arginine), or MC-LR, detection in the nanomolar range. The GCE|SDD–Co(II)|AgNPs aptatoxisensor was fabricated with 5’ thiolated aptamer through self-assembly on the modified surface of the glassy carbon electrode (GCE) and the electronic response was measured using cyclic voltammetry (CV). Specific binding of MC-LR with the aptamer on GCE|SDD–Co(II)|AgNPs aptatoxisensor caused the formation of a complex that resulted in steric hindrance and electrostatic repulsion culminating in variation of the corresponding peak current of the electrochemical probe. The aptatoxisensor showed a linear response for MC-LR between 0.1 and 1.1 µg·L−1 and the calculated limit of detection (LOD) was 0.04 µg·L−1. In the detection of MC-LR in water samples, the aptatoxisensor proved to be highly sensitive and stable, performed well in the presence of interfering analog and was comparable to the conventional analytical techniques. The results demonstrate that the constructed MC-LR aptatoxisensor is a suitable device for routine quantification of MC-LR in freshwater and environmental samples

    Spectroscopic Measurements of Dissolved O3, H2O2 and OH Radicals in Double Cylindrical Dielectric Barrier Discharge Technology: Treatment of Methylene Blue Dye Simulated Wastewater

    No full text
    Advanced oxidation technologies (AOTs) focusing on nonthermal plasma induced by dielectric barrier discharge are adequate sources of diverse reactive oxygen species (ROS) beneficial for water and wastewater treatment. In this study, indigo, peroxytitanyl sulphate and terephthalic acid methods were used to approximate the concentrations of O3, H2O2 and OH produced in a double cylindrical dielectric barrier discharge (DCDBD) plasma configuration. The effect of pH and scavengers as well as the amount of chemical probes on the generation of oxidants was investigated. The efficiency of the DCDBD reactor was further evaluated using methylene blue (MB) as model pollutant. The results demonstrated that the formation of oxidants O3, H2O2 and OH in the DCDBD reactor was pH-dependent. Furthermore, the presence of scavengers such as phosphates, bicarbonates and carbonates in the solution diminished the amount of OH in the system and hence could impact upon the degree of detoxification of targeted pollutants during water and wastewater treatment. The MB simulated dye was totally decomposed into H2O, dissolved CO2 and simpler aqueous entities. Herein the DCDBD design is an adequate AOT that can be used worldwide for effective decontamination of water and wastewater
    corecore