939 research outputs found
Recommended from our members
Hemoglobin contrast in magneto-motive optical doppler tomography, optical coherence tomography, and ultrasound imaging methods and apparatus
A novel contrast mechanism for imaging blood flow using magneto-motive optical Doppler tomography (MM-ODT), Optical Coherence Tomography, and Ultrasound. MM-ODT, OCT, and ultrasound combined with an externally applied temporally oscillating high-strength magnetic field detects erythrocytes moving according to the field gradient.Board of Regents, University of Texas Syste
Recommended from our members
Hemoglobin contrast in magneto-motive optical doppler tomography, optical coherence tomography, and ultrasound imaging methods and apparatus
Provided herein are systems, methods, and compositions for the use of optical coherence tomography for detection of cells.Board of Regents, University of Texas Syste
Recommended from our members
Systems and methods for altering visual acuity
Provided are systems operable to effect a temporary change in a modulation transfer function (MTF) of a target imaging system. The systems include a light source operable to produce light for transient propagation onto at least a portion of the target imaging system, a power source in operative communication with the light source and configured to effect the production of light from the light source, and a transmission unit in operative communication with the light source and configured to propagate the produced light onto at least a portion of the target imaging system. The propagated light is configured for absorbance by the portion of the target imaging system; the absorbance causes an increase in temperature and a change in a refractive index profile of at least the portion of the imaging system. The change in refractive index profile produces a temporary change in the MTF of the imaging system.Board of Regents, University of Texas Syste
Recommended from our members
Rotating catheter probe using a light-drive apparatus
The invention is a rotating tip catheter-imaging probe where electromagnetic energy is delivered to the distal end of a catheter and converted to mechanical energy using a light drive apparatus. The mechanical energy is then used to rotate a mirror that redirects light in fixed pattern on a sample. The rotating element of the light drive apparatus contains vanes, which rotate about an axis and positioned with bearings to minimize friction. A chamber encompasses the rotating element and is set to a vacuum pressure. The rotational speed of the catheter tip can be controlled by varying the optical power delivered to the vanes, the vacuum pressure in the chamber, or by a braking mechanism applied to the rotating element. The vanes may be shaped in a particular geometry to increase forces on the vanes from thermally driven gas flow.Board of Regents, University of Texas Syste
Recommended from our members
Polarization-sensitive spectral interferometry
A polarization sensitive spectral interferometer apparatus and method for analyzing a sample. The polarization sensitive spectral interferometer apparatus and method determines polarization properties of the sample.Board of Regents, University of Texas Syste
Recommended from our members
Polarization-sensitive spectral interferometry
A polarization sensitive spectral interferometer apparatus and method for analyzing a sample by optical energy reflected from the sample. The polarization sensitive spectral interferometer apparatus and method determines polarization properties of the sample by optical energy reflected from the sample.Board of Regents, University of Texas Syste
Recommended from our members
Polarization-sensitive spectral interferometry as a function of depth for tissue identification
A polarization sensitive spectral interferometer apparatus and method for analyzing a sample by optical energy reflected from the sample. The polarization sensitive spectral interferometer apparatus and method determines polarization properties of the sample by optical energy reflected from the sample. The method for analyzing a sample with a spectral interferometer identifies the tissue type of the sample by the polarization properties as a function of depth from the sample.Board of Regents, University of Texas Syste
Biophotonic Tools in Cell and Tissue Diagnostics.
In order to maintain the rapid advance of biophotonics in the U.S. and enhance our competitiveness worldwide, key measurement tools must be in place. As part of a wide-reaching effort to improve the U.S. technology base, the National Institute of Standards and Technology sponsored a workshop titled "Biophotonic tools for cell and tissue diagnostics." The workshop focused on diagnostic techniques involving the interaction between biological systems and photons. Through invited presentations by industry representatives and panel discussion, near- and far-term measurement needs were evaluated. As a result of this workshop, this document has been prepared on the measurement tools needed for biophotonic cell and tissue diagnostics. This will become a part of the larger measurement road-mapping effort to be presented to the Nation as an assessment of the U.S. Measurement System. The information will be used to highlight measurement needs to the community and to facilitate solutions
Soleus stretch reflex during cycling
The modulation and strength of the human soleus short latency stretch reflex was investigated by mechanically perturbing the ankle during an unconstrained pedaling task. Eight subjects pedaled at 60 rpm against a preload of 10 Nm. A torque pulse was applied to the crank at various positions during the crank cycle, producing ankle dorsiflexion perturbations of similar trajectory. The stretch reflex was greatest during the power phase of the crank cycle and was decreased to the level of background EMG during recovery. Matched perturbations were induced under static conditions at the same crank angle and background soleus EMG as recorded during the power phase of active pedaling. The magnitude of the stretch reflex was not statistically different from that during the static condition throughout the power phase of the movement. The results of this study indicate that the stretch reflex is not depressed during active cycling as has been shown with the H-reflex. This lack of depression may reflect a decreased susceptibility of the stretch reflex to inhibition, possibly originating from presynaptic mechanisms
- …