757 research outputs found

    Assessing the climate impacts of Chinese dietary choices using a telecoupled global food trade and local land use framework

    Get PDF
    Global emissions trajectories developed to meet the 2⁰C temperature target are likely to rely on the widespread deployment of negative emissions technologies and/or the implementation of substantial terrestrial carbon sinks. Such technologies include afforestation, carbon capture and storage (CCS) and bioenergy with carbon capture and storage (BECCS), but mitigation options for agriculture appear limited. For example, using the Global Calculator tool (http://www.globalcalculator.org/), under a 2⁰C pathway, the ‘forests and other land use’ sector is projected to become a major carbon sink, reaching -15 GtCO2e yr-1 by 2050, compared to fossil emissions of 21 GtCO2e yr-1. At the same time, rates of agricultural emissions remain static at about 6 GtCO2e yr-1, despite increasing demands for crop and livestock production to meet the forecast dietary demands of the growing and increasingly wealthy global population. Emissions in the Global Calculator are sensitive to the assumed global diet, and particularly to the level and type of meat consumption, which in turn drive global land use patterns and agricultural emissions. Here we assess the potential to use a modified down-scaled Global Calculator methodology embedded within the telecoupled global food trade framework, to estimate the agricultural emissions and terrestrial carbon stock impacts in China and Brazil, arising from a plausible range of dietary choices in China. These dietary choices are linked via telecoupling mechanisms to Brazilian crop production (e.g. Brazilian soy for Chinese animal feed provision) and drive land and global market dynamics. ‘Spill-over’ impacts will also be assessed using the EU and Malawi as case studies

    The Constructs and Practices of Job Placement

    Get PDF

    Reaction products of aquatic humic substances with chlorine.

    Get PDF
    A major concern of the chlorination of aquatic humic materials is the ubiquitous production of trihalomethanes. A large number of other chlorinated organic compounds, however, have been shown to be formed by chlorine's reaction with humic substances. In this study, humic material was concentrated from a coastal North Carolina lake and chlorinated at a chlorine to carbon mole ratio of 1.5 at pH 12. A high pH was necessary for complete dissolution of the humic material and for production of adequate quantities of oxidation and chlorination products for extraction, separation and mass spectrometric identification. After concentration in ether, samples were methylated, separated with a 50-m OV-17 glass capillary column or a 25 m SP-2100 fused-silica column and identified. A Hewlett-Packard 5710A gas chromatograph interfaced to a VG Micromass 7070F double-focusing mass spectrometer was used. Low resolution, accurate mass measurements were made with a combined EI-Cl source. The ability to do low resolution, accurate mass measurements made possible a rapid scan function necessary for capillary column gas chromatography. Accurate mass measurements allowed increased confidence in the identification of compounds, most of which are not available as standards. The products identified in these studies were chlorinated aliphatic straight-chain acids dominated by di- and trichloroacetic acid and the chlorinated dicarboxylic acids: succinic, fumaric and maleic acids. Chlorinated and unchlorinated aliphatic mono- and dicarboxylic acids and unchlorinated polycarboxylic aromatic acids comprise the remaining bulk of the compounds identified

    Feeding ecology and territoriality of the Cactus Finch Geospiza scandens on Isla Daphne Major, Galápagos

    Full text link
    In this study we investigated the relationship between food availability, feeding ecology and territoriality in a population of Cactus Finches, Geospiza scandens , on Isla Daphne Major, Galápagos, between 1979 and 1981.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47745/1/442_2004_Article_BF00384545.pd

    How primary care can contribute to good mental health in adults.

    Get PDF
    The need for support for good mental health is enormous. General support for good mental health is needed for 100% of the population, and at all stages of life, from early childhood to end of life. Focused support is needed for the 17.6% of adults who have a mental disorder at any time, including those who also have a mental health problem amongst the 30% who report having a long-term condition of some kind. All sectors of society and all parts of the NHS need to play their part. Primary care cannot do this on its own. This paper describes how primary care practitioners can help stimulate such a grand alliance for health, by operating at four different levels - as individual practitioners, as organisations, as geographic clusters of organisations and as policy-makers

    Comparison of 2.3 & 5 mega pixel (MP) resolution monitors when detecting mammography image blurring

    Get PDF
    Background - Image blurring in Full Field Digital Mammography (FFDM) is reported to be a problem within many UK breast screening units resulting in significant proportion of technical repeats/recalls. Our study investigates monitors of differing pixel resolution, and whether there is a difference in blurring detection between a 2.3 MP technical review monitor and a 5MP standard reporting monitor. Methods - Simulation software was created to induce different magnitudes of blur on 20 artifact free FFDM screening images. 120 blurred and non-blurred images were randomized and displayed on the 2.3 and 5MP monitors; they were reviewed by 28 trained observers. Monitors were calibrated to the DICOM Grayscale Standard Display Function. T-test was used to determine whether significant differences exist in blurring detection between the monitors. Results - The blurring detection rate on the 2.3MP monitor for 0.2, 0.4, 0.6, 0.8 and 1 mm blur was 46, 59, 66, 77and 78% respectively; and on the 5MP monitor 44, 70, 83 , 96 and 98%. All the non-motion images were identified correctly. A statistical difference (p <0.01) in the blurring detection rate between the two monitors was demonstrated. Conclusions - Given the results of this study and knowing that monitors as low as 1 MP are used in clinical practice, we speculate that technical recall/repeat rates because of blurring could be reduced if higher resolution monitors are used for technical review at the time of imaging. Further work is needed to determine monitor minimum specification for visual blurring detection

    A 6 year study of mammographic compression force : practitioner variability within and between screening sites

    Get PDF
    Background The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation dose and image quality. This research investigates practitioner compression force variation over a 6 year screening cycle in three different screening units. Methods: Recorded data included: practitioner code, applied compression force(N), breast thickness(mm), BI-RADS® density category. Exclusion criteria included: previous breast surgery, previous/ongoing assessment, breast implants. 975 clients (2925) client visits, 11,700 mammogram images) met inclusion criteria across three sites. Data analysis assessed practitioner variation of compression force and breast thickness. Results: Practitioners across three breast screening sites behave differently in the application of compression force. Two of the three sites demonstrate variability within themselves, though they demonstrated no significant difference in mean, first and third quartile compression force and breast thickness values CC(p&gt;0.5), MLO(p&gt;0.1) between themselves. However, the third site (where mandate dictates a minimum compression force is applied) greater consistency was demonstrated; a significant difference in mean, first and third quartile compression force and breast thickness values(p&lt;0.001) was demonstrated between this site and the other two sites. Conclusion: Stabilisation of variations in compression force may have a positive impact on image quality, radiation dose reduction, re-attendance levels and potentially cancer detection. The large variation in compression forces could negatively impact on client experience between the units and within a unit. Further research is required to establish best practice guidelines for compression force within mammography. Keywords: Compression force, Breast compression, Compression variabilit

    The perception and management of risk in UK office property development

    Get PDF
    Risk is an ever-present aspect of business, and risk taking is necessary for profit and economic progress. Speculative property development is popularly perceived as a 'risky business' yet, like other entrepreneurs, developers have opportunities to manage the risks they face; techniques include phasing and joint ventures. The associated areas of investment portfolio risk, development risk analysis and construction risk management have all been addressed by research. This article presents new knowledge about how developers perceive risks and the means they subsequently adopt to manage them. The developers of office projects across the UK were sent questionnaires by post. Respondents were asked about their perceptions of risks at the first appraisal stage and currently and about the risk management techniques that they had adopted. In-depth interviews with a selection of respondents were then used to discuss and augment the findings. Developers were most concerned about market-based risks at both stages. Concern about production-orientated risks was lower and fell significantly between the two stages. A fixed price contract was the most common risk management technique. Risk management techniques were used more often outside London and the South East. Developer type affects both the perception and management of risk. While developers do manage risk, decisions are made on the basis of professional and business experience. These findings should help development companies manage risk in a more objective and analytical way

    Extra patient movement during mammographic imaging : an experimental study

    Get PDF
    Objectives: To determine if movement external to the patient occurring during mammography may be a source of image blur. Methods: Four mammography machines with seven flexible and nine fixed paddles were evaluated. In the first stage, movement at the paddle was measured mechanically using two calibrated linear potentiometers. A deformable breast phantom was used to mimic a female breast. For each paddle, the movement in millimeters and change in compression force in Newton was recorded at 0.5 and 1 second intervals respectively for 40 seconds with the phantom in an initially compressed state under a load of 80N. In the second stage, clinical audit on 28 females was conducted on one mammography machine with the 18x24cm and 24x29cm flexible paddles. Results: Movement at the paddle followed an exponential decay with a settling period of approximately 40 seconds. The compression force readings for both fixed and flexible paddles decreased exponentially with time while fixed paddles have a larger drop in compression force than flexible paddles. There is a linear relationship between movement at the paddle and change in compression force. Conclusions: Movement measured at the paddle during an exposure can be represented by a second order system. The amount of extra-patient movement during the actual exposure can be estimated using the linear relationship between movement at the paddle and the change in compression force. Advances in knowledge: This research provides a possible explanation to mammography image blurring caused by extra patient movement and proposes a theoretical model to analyze the movement
    corecore