Device-detected atrial fibrillation and risk for stroke: an analysis of >10 000 patients from the SOS AF project (Stroke preventiOn Strategies based on Atrial Fibrillation information from implanted devices)
Objective: The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. Background: Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. Design, setting, and patients A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. Results: During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3–14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22–3.64, P = 0.008). Conclusions: Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment
Changes in Hematologic and Coagulation Profiles in Rabbits with Right-ventricle Pacing.
Abstract
Objectives: The aim of this study was to evaluate changes in hematology and coagulation in rabbits with right-ventricle pacing without medication.
Animals and methods: Blood was collected from ten non-anesthetized male rabbits from the jugular vein before and one month after pacemaker placement. Total erythrocyte, leukocyte and platelet count, hemoglobin, hematocrit and differential leukocyte count were done on automatic veterinary flow cytometry hematologic analyzer. Prothrombin time, activated partial thromboplastin time, fibrinogen level, D-dimers and kaolin-activated thromboelastography was measured from citrated blood.
Results: We found an increase in red blood cell mass and decrease in platelet count, while coagulation tests did not diff er between samplings.
Conclusion: Right-ventricle pacing seems to have no influence on hemostasis in rabbits
Differences in right-to-left vs left-to-right interventricular conduction times in patients indicated to cardiac resynchronization therapy.
INTRODUCTION:Differences in conduction times from right ventricle to left ventricle and from left ventricle to right ventricle respectively were observed during biventricular devices implantation when changing pacing vector direction. In this article the phenomenon of interventricular conduction time differences is described and assessed in relationship to various clinical and electrophysiological parameters. METHODS:In 62 consecutive patients (9 females) interventricular conduction times between right and left ventricle in both directions were measured during cardiac resynchronization therapy device implantation procedure. Complex pacing protocol was performed. RESULTS:Investigated individuals was divided into 3 subgroups according to type of interventricular conduction pattern and statistically tested with various clinical data. Substantial differences in right-to-left vs left-to-right conduction times (> 5 ms, range 7-72 ms) were observed in 24 (39%) of all patients. They were more common in patients with dilated cardiomyopathy (20 of 38, 53%) compared to 4 (17%) of 24 patients with coronary artery disease (p = 0.011). The phenomenon occurred more often in hypertensive patients (p = 0.012). Other tested factors were nonsignificant. CONCLUSIONS:There are almost no data on this topic. The occurrence of conduction difference phenomenon is quite common in dilated cardiomyopathy while it is rare in coronary artery disease. We assume the diffuse nature of the disease and the way of remodeling of myocardium play the main role. Knowledge of this phenomenon could be useful in personalized cardiac resynchronization therapy optimization
The yield of a comprehensive investigation protocol for the diagnosis of true idiopathic ventricular fibrillation in a real-life clinical setting
Abstract Traditionally, aborted cardiac arrest (ACA) due to documented ventricular fibrillation (VF) in the absence of structural heart disease has been termed idiopathic VF. By careful evaluation, a specific etiology can be found in a substantial proportion of patients. The aim of this survey was to assess the yield of an advanced diagnostic work-up to reveal a causative etiology in a real-life clinical setting. Patients from the University Hospital Brno’s ACA database were analyzed (514 patients in total). Forty-six patients (31 males) fulfilled the inclusion criteria, which were: (1) absence of structural pathology on echocardiography; (2) absence of coronary artery disease; and (3) absence of reversible cause of ACA. The diagnostic work-up consisted in cardiac magnetic resonance imaging, stress testing, sodium channel blocker challenge, and genetic testing according to the availability of the method and patient compliance. A specific disease was found in 17 individuals (37.0%), although at least one diagnostic step was refused by 13 patients (28.3%). True idiopathic VF was confirmed in 7 patients (15.2%), for whom the entire diagnostic work-up did not reveal any specific pathology. Our real-life survey shows that, even with an incomplete diagnostic work-up (due to the unavailability of a particular method or variable patient compliance), a specific diagnosis can be identified in more than one third of the cases of “idiopathic” VF, which can thus enable targeted treatment and family screening
Changes in Hematologic and Coagulation Profiles in Rabbits with Right-ventricle Pacing
The aim of this study was to evaluate changes in hematology and coagulation in rabbits with right-ventricle pacing without medication
Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden
Background: In patients with cardiac implanted electronic devices, detection of new atrial fibrillation (AF) is associated with an increased risk of stroke. Objective: To characterize daily AF burden at first detection and the rate of temporal transition to higher device-detected AF burden. Methods: A pooled analysis of data from 3 prospective projects was analyzed, and 6580 patients (mean age 68 ± 12 years, 72% male) with no history of AF and no use of anticoagulants at baseline were identified. Various thresholds of daily AF burden (5 minutes and 1, 6, 12, and 23 hours) were analyzed. Results: Among the study population of 6580 patients, a new AF, with an AF burden of ≥5 minutes, was detected in 2244 patients (34%) during a follow-up period of 2.4 ± 1.7 years. Among these patients, 1091 (49.8%) transitioned to a higher AF-burden threshold during follow-up. A higher duration of daily AF burden manifest at first detection and CHADS2 score ≥2 were associated with faster transition to a subsequent higher burden. Approximately 24% of patients transitioned from a lower threshold to a daily AF burden of ≥23 hours during follow-up. Conclusion: More than one-third of patients with no history of AF developed device-detected AF, with attainment of different thresholds of daily AF burden over time. Continuous long-term monitoring, especially when the initial detection corresponds to a higher daily AF burden and the CHADS2 score is ≥2, could support timely clinical decisions on anticoagulation by capturing transitions to higher AF-burden thresholds