4 research outputs found

    In Vivo Biomechanical Properties Of Heavy Versus Light Weight Monofilament Polypropylene Meshes. Does The Knitting Pattern Matter?

    No full text
    This work evaluated the post-implant biomechanical properties of light-weight (LW) and heavy-weight (HW) monofilament polypropylene (PP) meshes with different knitting patterns in an animal model in vivo. Forty-five adult female Wistar rats were divided into three groups and randomly implanted with 32 × 32 mm HW-PP (62 gm(-2) ) orLW-PP (16 gm(-2) ) in the lower abdomen. LW-PPwas tested orthogonally (called LWL and LWT) to reproduce the longitudinal and transverse planes of the vaginal wall, respectively. Abdominal walls were removed at 7, 30, and 60 days, and then tested for tensile load (maximum load until avulsion from the tissue), deflection, and stiffness to maximum load. Explants were compared over time and between groups. LW-PP meshes implanted in the LWT fashion (vaginal transverse plane) showed comparable maximum load and stiffness to HW-PP meshes, and LW-PP meshes implanted in the LWL fashion (vaginal longitudinal plane) presented lower maximum load and stiffness than the HW-PP meshes. There were no significant differences in the values of deflection at maximum load between the studied meshes as a function of time. The final mechanical behavior of PP mesh can be changed by its weight and knitting pattern. These properties may be useful in making more biocompatible prostheses for pelvic organ prolapse (POP) with less foreign material to maintain longitudinal vaginal elasticity and minimize sexual symptoms while maintaining transverse resistance (i.e., between vaginal fornixes) to prevent POP recurrence. Neurourol. Urodynam. © 2015 Wiley Periodicals, Inc

    Primary fixation of mini slings: a comparative biomechanical study in vivo

    No full text
    INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control), as follows: TVT-Secur® (Gynecare, USA), Type 1 polypropylene mesh (control); Ophira Mini Sling System® (Promedon, Argentina), Tissue Fixation System® (TFS PTY, Australia), Zipper Sling® and "T device" (Prosurg, USA). The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments). The force was measured in Newtons (N). RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified

    Pain Management During Office Hysteroscopy: A Survey of Hysteroscopists

    No full text
    Outpatient hysteroscopy can be a painful procedure for some patients and there is still no consensus regarding analgesia use. We evaluated which types and modalities of analgesia are most commonly used in a select group of hysteroscopists
    corecore