34 research outputs found

    Hemodynamic monitoring in the era of digital health

    Get PDF

    Clinical evaluation of a wearable sensor for mobile monitoring of respiratory rate on hospital wards

    Get PDF
    Publisher Copyright: © 2021, The Author(s).A wireless and wearable system was recently developed for mobile monitoring of respiratory rate (RR). The present study was designed to compare RR mobile measurements with reference capnographic measurements on a medical-surgical ward. The wearable sensor measures impedance variations of the chest from two thoracic and one abdominal electrode. Simultaneous measurements of RR from the wearable sensor and from the capnographic sensor (1 measure/minute) were compared in 36 ward patients. Patients were monitored for a period of 182 ± 56 min (range 68–331). Artifact-free RR measurements were available 81% of the monitoring time for capnography and 92% for the wearable monitoring system (p 20 (tachypnea) with a sensitivity of 81% and a specificity of 93%. In ward patients, the wearable sensor enabled accurate and precise measurements of RR within a relatively broad range (6–36 b/min) and the detection of tachypnea with high sensitivity and specificity.Peer reviewe

    Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water

    Get PDF
    A new system has been developed to assess global end-diastolic volume (GEDV), a volumetric marker of cardiac preload, and extravascular lung water (EVLW) from a transpulmonary thermodilution curve. Our goal was to compare this new system with the system currently in clinical use

    Automation of sub-aortic velocity time integral measurements by transthoracic echocardiography: clinical evaluation of an artificial intelligence-enabled tool in critically ill patients

    Get PDF
    © 2022 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.Point-of-care ultrasound techniques are increasingly used for the bedside assessment of cardiac function and haemodynamics in critically ill patients. The sub-aortic or left ventricular outflow tract velocity time integral (VTI) can be measured using pulsed-Doppler ultrasonography from a transthoracic apical 5-chamber view. Quantifying VTI is useful to discriminate between vasoplegic states (hypotension with normal/high VTI) and low flow states (low VTI). Measuring VTI is also useful to predict fluid responsiveness, either by quantifying the respiratory swings in VTI when patients are mechanically ventilated, or by quantifying VTI changes during a passive leg raising manoeuvre or a fluid challenge.info:eu-repo/semantics/publishedVersio

    Machine learning for the real-time assessment of left ventricular ejection fraction in critically ill patients: a bedside evaluation by novices and experts in echocardiography

    Get PDF
    © The Author(s) 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.Background: Machine learning algorithms have recently been developed to enable the automatic and real-time echocardiographic assessment of left ventricular ejection fraction (LVEF) and have not been evaluated in critically ill patients. Methods: Real-time LVEF was prospectively measured in 95 ICU patients with a machine learning algorithm installed on a cart-based ultrasound system. Real-time measurements taken by novices (LVEFNov) and by experts (LVEFExp) were compared with LVEF reference measurements (LVEFRef) taken manually by echo experts. Results: LVEFRef ranged from 26 to 80% (mean 54 ± 12%), and the reproducibility of measurements was 9 ± 6%. Thirty patients (32%) had a LVEFRef < 50% (left ventricular systolic dysfunction). Real-time LVEFExp and LVEFNov measurements ranged from 31 to 68% (mean 54 ± 10%) and from 28 to 70% (mean 54 ± 9%), respectively. The reproducibility of measurements was comparable for LVEFExp (5 ± 4%) and for LVEFNov (6 ± 5%) and significantly better than for reference measurements (p < 0.001). We observed a strong relationship between LVEFRef and both real-time LVEFExp (r = 0.86, p < 0.001) and LVEFNov (r = 0.81, p < 0.001). The average difference (bias) between real time and reference measurements was 0 ± 6% for LVEFExp and 0 ± 7% for LVEFNov. The sensitivity to detect systolic dysfunction was 70% for real-time LVEFExp and 73% for LVEFNov. The specificity to detect systolic dysfunction was 98% both for LVEFExp and LVEFNov. Conclusion: Machine learning-enabled real-time measurements of LVEF were strongly correlated with manual measurements obtained by experts. The accuracy of real-time LVEF measurements was excellent, and the precision was fair. The reproducibility of LVEF measurements was better with the machine learning system. The specificity to detect left ventricular dysfunction was excellent both for experts and for novices, whereas the sensitivity could be improved.info:eu-repo/semantics/publishedVersio