    Contribution of exposure and genetics to the development of beryllium sensitization and chronic beryllium disease

    Get PDF
    Department Head: Jac A. Nickoloff.2010 Spring.Includes bibliographical references.To view the abstract, please see the full text of the document

    Exposure databases and exposure surveillance : promise and practice

    Full text link
    Based on recent developments in occupational health and a review of industry practices, it is argued that integrated exposure database and surveillance systems hold considerable promise for improving workplace health and safety. A foundation from which to build practical and effective exposure surveillance systems is proposed based on the integration of recent developments in electronic exposure databases, the codification of exposure assessment practice, and the theory and practice of public health surveillance. The merging of parallel, but until now largely separate, efforts in these areas into exposure surveillance systems combines unique strengths from each subdiscipline. The promise of exposure database and surveillance systems, however, is yet to be realized. Exposure surveillance practices in general industry are reviewed based on the published literature as well as an Internet survey of three prominent industrial hygiene e-mail lists. Although the benefits of exposure surveillance are many, relatively few organizations use electronic exposure databases, and even fewer have active exposure surveillance systems. Implementation of exposure databases and surveillance systems can likely be improved by the development of systems that are more responsive to workplace or organizational-level needs. An overview of exposure database software packages provides guidance to readers considering the implementation of commercially available systems. Strategies for improving the implementation of exposure database and surveillance systems are outlined. A companion report in this issue on the development and pilot testing of a workplace-level exposure surveillance system concretely illustrates the application of the conceptual framework proposed

    Cleanup worker exposures to hazardous chemicals at a former nuclear weapons plant : piloting of an exposure surveillance system

    Full text link
    Cleanup of former U.S. Department of Energy (DOE) nuclear weapons production facilities involves potential exposures to various hazardous chemicals. We have collaboratively developed and piloted an exposure database and surveillance system for cleanup worker hazardous chemical exposure data with a cleanup contractor at the Rocky Flats Environmental Technology Site (RFETS). A unique system feature is the incorporation of a 34-category work task-coding scheme. This report presents an overview of the data captured by this system during development and piloting from March 1995 through August 1998. All air samples collected were entered into the system. Of the 859 breathing zone samples collected, 103 unique employees and 39 unique compounds were represented. Breathing zone exposure levels were usually low (86% of breathing zone samples were below analytical limits of detection). The use of respirators and other exposure controls was high (87 and 88%, respectively). Occasional high-level excursions did occur. Detailed quantitative summaries are provided for the six most monitored compounds: asbestos, beryllium, carbon tetrachloride, chromium, lead, and methylene chloride. Task and job title data were successfully collected for most samples, and showed specific cleanup activities by pipe fitters to be the most commonly represented in the database. Importantly, these results demonstrate the feasibility of the implementation of integrated exposure database and surveillance systems by practicing industrial hygienists employed in industry as well as the preventive potential and research uses of such systems. This exposure database and surveillance system--the central features of which are applicable in any industrial work setting--has enabled one of the first systematic quantitative characterizations of DOE cleanup worker exposures to hazardous chemicals

    Development of an exposure database and surveillance system for use by practicing OSH professionals

    Full text link
    This report summarizes the development of an occupational exposure database and surveillance system for use by health and safety professionals at Rocky Flats Environmental Technology Site (RFETS), a former nuclear weapons production facility. The site itself is currently in the cleanup stage with work expected to continue into 2006. The system was developed with the intent of helping health and safety personnel not only to manage and analyze exposure monitoring data, but also to identify exposure determinants during the highly variable cleanup work. Utilizing a series of focused meetings with health and safety personnel from two of the major contractors at RFETS, core data elements were established. These data elements were selected based on their utility for analysis and identification of exposure determinants. A task-based coding scheme was employed to better define the highly variable work. The coding scheme consisted of a two-tiered hierarchical list with a total of 34 possible combinations of work type and task. The data elements were incorporated into a Microsoft Access database with built-in data entry features to both promote consistency and limit entry choices to enable stratified analyses. In designing the system, emphasis was placed on the ability of end users to perform complex analyses and multiparameter queries to identify trends in their exposure data. A very flexible and user-friendly report generator was built into the system. This report generator allowed users to perform multiparameter queries using an intuitive system with very little training. In addition, a number of automated graphical analyses were built into the system, including ex posure levels by any combination of building, date, employee, job classification, type of contaminant, work type or task, exposure levels over time, exposure levels relative to the permissible exposure limit (PELS), and distributions of exposure levels. Both of these interfaces, allow the user to \u27\u27drill down\u27\u27 or gradually narrow query criteria to identify specific exposure determinants. A number of other industrial hygiene processes were automated by the use of this database. Exposure calculations were coded into the system to allow automatic calculation of time-weighted averages and sample volumes. In addition, a table containing all the PELs and other relevant occupational exposure limits was built into the system to allow automatic comparisons with the current standards. Finally, the process of generating reports for employee notification was automated. The implementation of this system demonstrates that an integrated database system can save time for a practicing hygienist as well as provide useful and more importantly, timely information to guide primary prevention efforts

    Development and piloting of an exposure database and surveillance system for DOE cleanup operations

    Full text link
    An industrial hygiene exposure database and surveillance system was developed in partnership between National Institute for Occupational Safety and Health (NIOSH)-funded independent investigators and practicing industrial hygienists at the Rocky Flats Environmental Technology Site (RFETS) in Golden, Colo. RFETS is a former U.S. Department of Energy nuclear weapons plant that is now in cleanup phase. This project is presented as a case study in the development of an exposure database and surveillance system in terms that are generalizable to most other industries and work contexts. Steps include gaining organizational support; defining system purpose and scope; defining database elements and coding; planning practical and efficient analysis strategies; incorporating reporting capabilities; and anticipating communication strategies that maximize the probability that surveillance findings will feed back to preventive applications. For each of these topics, the authors describe both general considerations as well as the specific choices made for this system. An important feature of the system is a two-tier task-coding scheme comprising 33 categories of task groups. Examples of grouped analyses of exposure data captured during the system pilot period demonstrate applications to exposure control, medical surveillance, and other preventive measures. Reprinted by permission of the publisher

    Integrating workplace exposure databases for occupational medicine services and epidemiologic studies at a former nuclear weapons facility

    Full text link
    We outline methods for integrating epidemiologic and industrial hygiene data systems for the purpose of exposure estimation, exposure surveillance, worker notification, and occupational medicine practice. We present examples of these methods from our work at the Rocky Flats Plant?a former nuclear weapons facility that fabricated plutonium triggers for nuclear weapons and is now being decontaminated and decommissioned. The weapons production processes exposed workers to plutonium, gamma photons, neutrons, beryllium, asbestos, and several hazardous chemical agents, including chlorinated hydrocarbons and heavy metals. We developed a job exposure matrix (JEM) for estimating exposures to 10 chemical agents in 20 buildings for 120 different job categories over a production history spanning 34 years. With the JEM, we estimated lifetime chemical exposures for about 12,000 of the 16,000 former production workers. We show how the JEM database is used to estimate cumulative exposures over different time periods for epidemiological studies and to provide notification and determine eligibility for a medical screening program developed for former workers. We designed an industrial hygiene data system for maintaining exposure data for current cleanup workers. We describe how this system can be used for exposure surveillance and linked with the JEM and databases on radiation doses to develop lifetime exposure histories and to determine appropriate medical monitoring tests for current cleanup workers. We also present time-line-based graphical methods for reviewing and correcting exposure estimates and reporting them to individual workers

    BHPR research: qualitative1. Complex reasoning determines patients' perception of outcome following foot surgery in rheumatoid arhtritis

    Get PDF
    Background: Foot surgery is common in patients with RA but research into surgical outcomes is limited and conceptually flawed as current outcome measures lack face validity: to date no one has asked patients what is important to them. This study aimed to determine which factors are important to patients when evaluating the success of foot surgery in RA Methods: Semi structured interviews of RA patients who had undergone foot surgery were conducted and transcribed verbatim. Thematic analysis of interviews was conducted to explore issues that were important to patients. Results: 11 RA patients (9 ♂, mean age 59, dis dur = 22yrs, mean of 3 yrs post op) with mixed experiences of foot surgery were interviewed. Patients interpreted outcome in respect to a multitude of factors, frequently positive change in one aspect contrasted with negative opinions about another. Overall, four major themes emerged. Function: Functional ability & participation in valued activities were very important to patients. Walking ability was a key concern but patients interpreted levels of activity in light of other aspects of their disease, reflecting on change in functional ability more than overall level. Positive feelings of improved mobility were often moderated by negative self perception ("I mean, I still walk like a waddling duck”). Appearance: Appearance was important to almost all patients but perhaps the most complex theme of all. Physical appearance, foot shape, and footwear were closely interlinked, yet patients saw these as distinct separate concepts. Patients need to legitimize these feelings was clear and they frequently entered into a defensive repertoire ("it's not cosmetic surgery; it's something that's more important than that, you know?”). Clinician opinion: Surgeons' post operative evaluation of the procedure was very influential. The impact of this appraisal continued to affect patients' lasting impression irrespective of how the outcome compared to their initial goals ("when he'd done it ... he said that hasn't worked as good as he'd wanted to ... but the pain has gone”). Pain: Whilst pain was important to almost all patients, it appeared to be less important than the other themes. Pain was predominately raised when it influenced other themes, such as function; many still felt the need to legitimize their foot pain in order for health professionals to take it seriously ("in the end I went to my GP because it had happened a few times and I went to an orthopaedic surgeon who was quite dismissive of it, it was like what are you complaining about”). Conclusions: Patients interpret the outcome of foot surgery using a multitude of interrelated factors, particularly functional ability, appearance and surgeons' appraisal of the procedure. While pain was often noted, this appeared less important than other factors in the overall outcome of the surgery. Future research into foot surgery should incorporate the complexity of how patients determine their outcome Disclosure statement: All authors have declared no conflicts of interes

    Frequency drift in MR spectroscopy at 3T

    Get PDF
    Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B-0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC).Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p &lt; 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI.Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.</p
    corecore