44 research outputs found

    Peritoneal Carcinomatosis in Primary Ovarian Cancer Staging: Comparison Between MDCT, MRI, and 18F-FDG PET/CT.

    Get PDF
    PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension

    Severe pelvic injury: vascular lesions detected by ante- and post-mortem contrast medium-enhanced CT and associations with pelvic fractures.

    Get PDF
    The objectives of this study were to compare arterial and venous contrast medium extravasation in severe pelvic injury detected by ante- and post-mortem multi-detector CT (MDCT) and determine whether vascular injury is associated with certain types of pelvic fracture. We retrospectively included two different cohorts of blunt pelvic trauma with contrast medium extravasation shown by MDCT. The first group comprised 49 polytrauma patients; the second included 45 dead bodies undergoing multi-phase post-mortem CT-angiography (MPMCTA). Two radiologists jointly reviewed each examination concerning type, site of bleeding and pattern of underlying pelvic ring fracture. All 49 polytrauma patients demonstrated arterial bleeding, immediately undergoing subsequent angiography; 42 (85%) had pelvic fractures, but no venous bleeding was disclosed. MPMCTA of 45 bodies revealed arterial (n = 33, 73%) and venous (n = 35, 78%) bleeding and pelvic fractures (n = 41, 91%). Pelvic fracture locations were significantly correlated with ten arterial and six venous bleeding sites in dead bodies, with five arterial bleeding sites in polytrauma patients. In dead bodies, arterial haemorrhage was significantly correlated with the severity of pelvic fracture according to Tile classification (p = 0.01), unlike venous bleeding (p = 0.34). In severe pelvic injury, certain acute bleeding sites were significantly correlated with underlying pelvic fracture locations. MPMCTA revealed more venous lesions than MDCT in polytrauma patients. Future investigations should evaluate the proportional contribution of venous bleeding to overall pelvic haemorrhage as well as its clinical significance

    Initial Staging of Locally Advanced Rectal Cancer and Regional Lymph Nodes: Comparison of Diffusion-Weighted MRI With 18F-FDG-PET/CT.

    Get PDF
    The aim of the study was to compare diffusion-weighted MRI (DW-MRI) parameters with 18F-FDG PET/CT in primary locally advanced rectal cancer (LARC). From October 2012 to September 2014, 24 patients with histologically confirmed and untreated LARC (T3-T4) prospectively underwent a pelvic 1.5-T DW-MRI (b = 0 s/mm, b = 600 s/mm2) and a whole-body 18F-FDG PET/CT, before neoadjuvant therapy. The 2 examinations were performed on the same day. Two readers measured 18F-FDG SUVmax and SUVmean of the rectal tumor and of the pathological regional lymph nodes on PET/CT and compared these with minimum and mean values of the ADC (ADCmin and ADCmean) on maps generated from DW-MRI. The diagnostic performance of ADC values in identifying pathological lymph nodes was also assessed. Regarding tumors (n = 24), we found a significant negative correlation between SUVmean and corresponding ADCmean values (ρ = -0.61, P = 0.0017) and between ADCmin and SUVmax (ρ = -0.66, P = 0.0005). Regarding the lymph nodes (n = 63), there was a significant negative correlation between ADCmean and SUVmean values (ρ = -0.38, P = 0.0021), but not between ADCmin and SUVmax values (ρ = -0.11, P = 0.41). Neither ADCmean nor ADCmin values helped distinguish pathological from benign lymph nodes (AUC of 0.24 [confidence interval, 0.10-0.38] and 0.41 [confidence interval, 0.22-0.60], respectively). The correlations between ADCmean and SUVmean suggest an association between tumor cellularity and metabolic activity in untreated LARC and in regional lymph nodes. However, compared with 18F-FDG PET/CT, ADC values are not reliable for identifying pathological lymph nodes

    Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images.

    Get PDF
    To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm <sup>2</sup> , respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm <sup>2</sup> , respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality

    Pulmonary embolism during pregnancy: a 17-year single-center retrospective MDCT pulmonary angiography study.

    Get PDF
    To determine the prevalence of pulmonary embolism (PE) and alternative diagnoses detected by computed tomography pulmonary angiography (CTPA) in pregnant women; and to assess changes over time regarding radiation dose, technical quality, and examination frequency. This retrospective study included all pregnant women referred for CTPA due to clinically suspected PE over 17 years. Two blinded radiologists reviewed the CTPAs in consensus with regard to PE, alternative diagnoses, and technical quality. We retrieved patient data regarding radiation dose metrics and associated clinical and laboratory parameters. Subgroup comparisons were performed (Wilcoxon and Kruskal-Wallis tests). Of the 237 identified patients, 8 (3.3%) were excluded due to inadequate technical CTPA quality, and 229 patients were analyzed (mean age, 31.7 years; mean gestational age, 28 ± 7 weeks). The four different CT systems used over the study period had similar technical quality (p = 0.28). Of 229 patients 16 (7%) patients had PE, 144 (62.9%) had no abnormal findings, and 69 (30.1%) had an alternative diagnosis (consolidation, other pulmonary opacities, pleural effusion, and basal atelectasis). Gestational age, symptoms, and D-dimer levels were not significantly different between patients with or without PE (p > 0.05). Over time, radiation dose exposure decreased by 30% (p < 0.001), while the number of annual examinations increased by > 4-folds. In pregnant women, CTPA rarely indicates PE and more often shows alternative diagnoses. Over 17 years, the use of CTPA in pregnancy has notably increased, while the radiation dose exposure has decreased by one third. • The use of CTPA in pregnancy has steadily risen over the last 17 years • In pregnant women, CTPA rarely reveals PE and more often shows alternative diagnoses • Recent technical improvements have substantially decreased the radiation dose exposure inherent in CTPA without reducing diagnostic image quality

    Multisensory interactions within human primary cortices revealed by BOLD dynamics.

    Get PDF
    Whether signals from different sensory modalities converge and interact within primary cortices in humans is unresolved, despite emerging evidence in animals. This is partially because of debates concerning the appropriate analyses of functional magnetic resonance imaging (fMRI) data in response to multisensory phenomena. Using event-related fMRI, we observed that simple auditory stimuli (noise bursts) activated primary visual cortices and that simple visual stimuli (checkerboards) activated primary auditory cortices, indicative of multisensory convergence. Moreover, analyses of blood oxygen level-dependent response dynamics revealed facilitation of hemodynamic response peak latencies and slopes for multisensory auditory-visual stimuli versus either unisensory condition, indicative of multisensory interactions within primary sensory cortices. Neural processing at the lowest cortical levels can be modulated by interactions between the senses. Temporal information in fMRI data can reveal these modulations and overcome analytic and interpretational challenges of more traditional procedures. In addition to providing an essential translational link with animal models, these results suggest that longstanding notions of cortical organization need to be revised to include multisensory interactions as an inherent component of functional brain organization

    Rivastigmine decreases brain damage in HIV patients with mild cognitive deficits.

    Get PDF
    Rivastigmine has been shown to improve cognition in HIV+ patients with minor neurocognitive disorders; however, the mechanisms underlying such beneficial effect are currently unknown. To assess whether rivastigmine therapy is associated with decreased brain inflammation and damage, we performed T1/T2* relaxometry and magnetization transfer imaging in 17 aviremic HIV+ patients with minor neurocognitive disorders enrolled on a crossed over randomized rivastigmine trial. Rivastigmine therapy was associated with changes in MRI metrics indicating a decrease in brain water content (i.e., edema reabsorption) and/or reduced demyelination/axonal damage. Furthermore, MRI changes correlated with cognitive improvement on rivastigmine therapy
    corecore