110 research outputs found

    Mid-term outcomes after distally locked-to-standard primary stem exchange in 29 hip-prosthesis patients

    Get PDF
    AbstractBackgroundCementless locked femoral stems are used for revision surgery in patients with bone loss to induce spontaneous bone reconstruction, allowing subsequent replacement by a standard primary stem. The small number of patients and short follow-ups available to date preclude a valid assessment of this strategy.HypothesisAfter distally locked stem revision, replacement by a standard primary stem does not induce complications, and the quality of the bone reconstruction allows strong fixation of a regular primary stem.Materials and methodsWe retrospectively evaluated 29 patients in whom a distally locked femoral stem was replaced by a standard primary stem between 1998 and 2010 (cemented in 27, cementless in 2 cases). The reason for the procedure was stem breakage, stem migration, or thigh pain. Mean patient age was 63years (range, 39–78years). Outcomes were evaluated based on the Postel-Merle d’Aubigné [PMA] score and Harris Hip Score [HHS]. In addition, radiographs were obtained to assess prosthesis fixation and the Hofmann cortical index measured the bone reconstruction.ResultsThe distally locked stem was removed via a postero-lateral approach without femoral osteotomy in all the 29 cases. In one patient, an intra-operative fracture occurred during femoral preparation. Mean follow-up after the exchange procedure was 75months (range, 3–188months). Postoperative ccomplications occurred in 9 (32%) patients and consisted of chronic infection in 2 patients (after 3 and 76months), post-traumatic peri-prosthetic fractures treated with internal fixation in 3 patients (after 100, 138, and 182months), aseptic loosening in 3 patients (after 13, 39, and 122months), and recurrent instability in one patient (after 63months). All cause revision stem survival after 75months was 72% (95% confidence interval, 47%–87%). In the 19 patients who still had their revision stem at last follow-up, the mean PMA score was 16.7 (range, 13–18) and the mean HHS was 88.2 (range, 59–99). The Hofmann index remained unchanged [36.5% (range, 28%–58%) before the exchange and 32.9% (range, 20%–57%) after the exchange; P=0.129].DiscussionThis study confirms the feasibility of substituting a distally locked stem with a standard primary stem. No specific complications occurred and no technical difficulties arose when extracting the long stems. However, the 32% complication rate and, more specifically, the occurrence of loosening in 10% (3/29) of patients mandates caution in the use of this technique, which should not be proposed routinely, and suggests a need for considering cementless fixation of the standard primary stem.Level of evidenceLevel IV, retrospective study

    Long-term Site Fidelity and Individual Home Range Shifts in Lophocebus albigena

    Get PDF
    We investigated long-term site fidelity of gray-cheeked mangabey (Lophocebus albigena) groups in Kibale National Park, Uganda. Concurrently, we monitored shifts in home range by individual females and subadult and adult males. We documented home range stability by calculating the area of overlap in successive years, and by recording the drift of each group’s monthly centroid from its initial location. Home ranges remained stable for 3 of our 4 groups (overlap over 10 yr >60%). Core areas were more labile, but group centroids drifted an average of only 530 m over the entire decade. Deviations from site fidelity were associated with dispersal or group fission. During natal dispersal, subadult males expanded their home ranges over many months, settling ≤4 home ranges away. Adult males, in contrast, typically dispersed within a few days to an adjacent group in an area of home range overlap. Adult males made solitary forays, but nearly always into areas used by their current group or by a group to which they had previously belonged. After secondary dispersal, they expanded their ranging in the company of their new group, apparently without prior solitary exploration of the new area. Some females also participated in home range shifts. Females shifted home ranges only within social groups, in association with temporary or permanent group splits. Our observations raise the possibility that male mangabeys use a finder-joiner mechanism when moving into new home ranges during secondary dispersal. Similarly, females might learn new resource locations from male immigrants before or during group fission

    Sexual Signalling in Propithecus verreauxi: Male “Chest Badge” and Female Mate Choice

    Get PDF
    Communication, an essential prerequisite for sociality, involves the transmission of signals. A signal can be defined as any action or trait produced by one animal, the sender, that produces a change in the behaviour of another animal, the receiver. Secondary sexual signals are often used for mate choice because they may inform on a potential partner's quality. Verreaux's sifaka (Propithecus verreauxi) is characterized by the presence of two different morphs of males (bimorphism), which can show either a stained or clean chest. The chest becomes stained by secretions of the sternal gland during throat marking (rubbing throat and chest on a vertical substrate while smearing the scent deposition). The role of the chest staining in guiding female mate choice was previously hypothesized but never demonstrated probably due to the difficulty of observing sifaka copulations in the wild. Here we report that stained-chested males had a higher throat marking activity than clean-chested males during the mating season, but not during the birth season. We found that females copulated more frequently with stained-chested males than the clean-chested males. Finally, in agreement with the biological market theory, we found that clean-chested males, with a lower scent-releasing potential, offered more grooming to females. This “grooming for sex” tactic was not completely unsuccessful; in fact, half of the clean-chested males copulated with females, even though at low frequency. In conclusion, the chest stain, possibly correlated with different cues targeted by females, could be one of the parameters which help females in selecting mates

    The myocardial sleeves of the pulmonary veins: potential implications for atrial fibrillation

    No full text

    Type I fractures

    No full text

    One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: Serum metal ion levels and clinical outcomes

    Get PDF
    SummaryIntroductionThe good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with large-diameter implants are causing concern. To determine whether these events are related to the geometry and metal composition of the prosthesis components, we conducted a prospective study of clinical outcomes and serum chromium and cobalt levels 1 year after implantation of three different acetabular cups.HypothesisSerum levels of metal ions are comparable with different types of large-diameter metal-on-metal total hip prostheses.Patients and methodsWe compared 24 Durom™ cups (D), 23 M2a Magnum™ cups (M2a), and 20 Conserve Total™ (C) cups regarding serum chromium and cobalt levels, Postel-Merle d’Aubigné (PMA) scores and Oxford Hip Scores (OHS), as well as radiographic cup orientation and position at 1-year follow-up. Mean age was 66 years (45–85 years), mean body mass index was 28 Kg/m2 (18–45), patients were almost equally divided between males and females, and the reason for hip replacement was primary hip osteoarthritis in 65 patients and avascular necrosis in two. Metal ions were assayed in serum from blood drawn through non-metallic catheters, using mass spectrometry.ResultsDislocation occurred in two patients (one D and one M2a) and revision to change the bearing couple was required in two patients in the D group. Serum cobalt levels in the C group were significantly higher (P=0. 0003) than in the two other groups (7.5μg/L versus 2. 7μg/L with D and 2. 2μg/L with M2a). Clinical outcomes were better in the M2a group (PMA, 17.7 [16–18]; and OHS, 15.2 [12–30]; P<0.05). The PMA score and OHS were 17.5 (16–18) and 18.2 (12–42), respectively, with D; and 16.75 (10–18) and 22. 2 (12–42), respectively, with C cups. When all three cup models were pooled, serum ion levels were higher in patients with pain than without pain (chromium, 7.1μg/L versus 2.1μg/L [P=0.002], and cobalt, 8μg/L versus 2.6μg/L [P=0.0004]).DiscussionSerum chrome and cobalt levels increased after metal-on-metal total hip replacement, and the increase was greater with large-diameter implants than previously reported with 28-mm implants. Persistent pain was significantly associated with higher metal ion levels, with a probable cobalt cut-off of about 8μg/L. Differences in modular head-neck concepts may explain the observed variations.Level of evidenceIII, prospective comparative study
    corecore