9 research outputs found

    Limited Urethral Mobilization Technique in Distal Hypospadias Repair with Satisfactory Results

    No full text
    Objective: To assess the outcomes of the Limited Urethral Mobilization (LUM) technique in distal hypospadias repair.Material and Methods: Forty-seven patients, who were operated on with the LUM technique iduring a 6 years period, were grouped according to their ages. Age distribution in Group 1 (n=37) and Group 2 (n=10) were 6-36 and 37-72 months. Meatal localization was glanular in 31, coronal in 7 and sub-coronal in 9 patients. Nine patients were secondary cases. The urethra proximal to the meatus was mobilized for a distance sufficient to allow it to reach the glans tip without tension. Then, the urethra was placed in the glanular bed and glanular reconstruction was performed. Operation duration, distance between the urethral meatus and the glans tip; and urethral mobilization length were measured and post-operative complications were noted.Results: Operation durations were similar in both groups. Three-fold urethral mobilization was sufficient for construction of tension-free urethra-glanular anastomosis. No fistula or retraction of the urethral meatus and chordee were observed. One patient required meatotomy. Conclusion: Distal hypospadias repair with the LUM technique is simple and effective. As no new urethral tube is constructed there is no risk of fistula. A slit-like urethral meatus with good functional results was obtained with the use of theLUM technique

    The Effect of Two Different Bonding Agents and Thermal Cycling on the Shear Bond Strength of Autopolymerizing Acrylic Resin to Cobalt-Chromium Alloy

    No full text
    İki farklı bağlayıcı ajan ve termal siklus uygulamasının iskelet protezlerin üreti-- minde kullanılan kobalt--krom (Co--Cr) alaşımı ile otopolimerizan akrilik rezinin makaslama bağ-- lantı dayanımına etkisini incelemektir. Gereç ve Yöntemler. Altmış adet disk şeklindeki Co--Cr metal alaşımından örnekler hazırlanan farklı tamir işlemleri için gruba [(n=20): Grup 1; sadece kumlama (kontrol grubu), Grup 2; kumlama ve Alloy Primer uygulama, Grup 3; kumlama ve Gluma Bond uygulama] ayrıldı. Her bir gruptaki örnekler üzerine otopolimerizan soğuk akrilik mm yüksekliğinde ve mm çapında olacak şekilde uygulandı. Makaslama bağlantı dayanımı testi her bir gruptaki örneklerin yarısına otopolimerize akrilik uygulamasından 24 saat sonra, diğer yarısına da termal siklus uygulandıktan sonra Universal Test Cihazı ile 0,5 mm/dk makas-- lama hızı kullanılarak yapıldı. Bu testten elde edilen veriler iki yönlü ANOVA testi ve eşleştiril-- miş örneklem t--testleri kullanılarak yapıldı (p0,05) hariç diğer gruplar üzerinde etkisi olduğu bulundu (p0.05). The highest shear bond strength was observed in Group without thermal cycling (12.00 MPa) and the lowest shear bond strength was observed in control group after thermal cycling (1.41 MPa) (p<0.05). Conclusion: It could be concluded that the observed bonding agents significantly improve the shear bond strength of acrylic resin to the Co—Cr alloy, and the effect of thermal cycling demon— strated that Alloy Primer is more favourable for the long—term success of Co—Cr alloy—acrylic resin bond

    The Effect of Two Different Bonding Agents and Thermal Cycling on the Shear Bond Strength of Autopolymerizing Acrylic Resin to Cobalt—Chromium Alloy

    No full text
    İki farklı bağlayıcı ajan ve termal siklus uygulamasının iskelet protezlerin üreti-- minde kullanılan kobalt--krom (Co--Cr) alaşımı ile otopolimerizan akrilik rezinin makaslama bağ-- lantı dayanımına etkisini incelemektir. Gereç ve Yöntemler. Altmış adet disk şeklindeki Co--Cr metal alaşımından örnekler hazırlanan farklı tamir işlemleri için gruba [(n=20): Grup 1; sadece kumlama (kontrol grubu), Grup 2; kumlama ve Alloy Primer uygulama, Grup 3; kumlama ve Gluma Bond uygulama] ayrıldı. Her bir gruptaki örnekler üzerine otopolimerizan soğuk akrilik mm yüksekliğinde ve mm çapında olacak şekilde uygulandı. Makaslama bağlantı dayanımı testi her bir gruptaki örneklerin yarısına otopolimerize akrilik uygulamasından 24 saat sonra, diğer yarısına da termal siklus uygulandıktan sonra Universal Test Cihazı ile 0,5 mm/dk makas-- lama hızı kullanılarak yapıldı. Bu testten elde edilen veriler iki yönlü ANOVA testi ve eşleştiril-- miş örneklem t--testleri kullanılarak yapıldı (p0,05) hariç diğer gruplar üzerinde etkisi olduğu bulundu (p0.05). The highest shear bond strength was observed in Group without thermal cycling (12.00 MPa) and the lowest shear bond strength was observed in control group after thermal cycling (1.41 MPa) (p<0.05). Conclusion: It could be concluded that the observed bonding agents significantly improve the shear bond strength of acrylic resin to the Co—Cr alloy, and the effect of thermal cycling demon— strated that Alloy Primer is more favourable for the long—term success of Co—Cr alloy—acrylic resin bond

    LigaSure compared with ligatures and endoclips in experimental appendectomy:How safe is it?

    No full text
    The present study aims to compare strength, healing, and inflammation of appendiceal stumps closed by LigaSure Precise (TM) (Valleylab, Boulder, CO, USA) device, ligatures using polyglactin 910 (Vicryl, Ethicon, Edinburgh, UK) and endoclips (Ligaclip ERCA, Ethicon, OH, USA), and operation time (OT) in experimental appendectomy
    corecore