20 research outputs found
Update on imaging of ovarian cancer
This review will make familiar with new concepts
in ovarian cancer and their impact on radiological
practice. Disseminated peritoneal spread and ascites are
typical of the most common (70–80 %) cancer type, highgrade
serous ovarian cancer. Other cancer subtypes differ
in origin, precursors, and imaging features. Expert sonography
allows excellent risk assessment in adnexal masses.
Owing to its high specificity, complementary MRI
improves characterization of indeterminate lesions. Major
changes in the new FIGO staging classification include
fusion of fallopian tube and primary ovarian cancer and the
subcategory stage IIIA1 for retroperitoneal lymph node
metastases only. Inguinal lymph nodes, cardiophrenic
lymph nodes, and umbilical metastases are classified as
distant metastases (stage IVB). In multidisciplinary conferences
(MDC), CT has been used to predict the success of
cytoreductive surgery. Resectability criteria have to be
specified and agreed on in MDC. Limitations in detection
of metastases may be overcome using advanced MRI
techniques
Humor in radiological breast cancer screening: a way of improving patient service?
BACKGROUND
Breast cancer screening is essential in detecting breast tumors, however, the examination is stressful. In this study we analyzed whether humor enhances patient satisfaction.
METHODS
In this prospective randomized study 226 patients undergoing routine breast cancer screening at a single center during October 2020 to July 2021 were included. One hundred thirty-two were eligible for the study. Group 1 (66 patients) received an examination with humorous intervention, group 2 (66 patients) had a standard breast examination. In the humor group, the regular business card was replaced by a self-painted, humorous business card, which was handed to the patient at the beginning of the examination. Afterwards, patients were interviewed with a standardized questionnaire. Scores between the two study groups were compared with the Mann-Whitney U test or Fisher's exact test. P-values were adjusted with the Holm's method. Two-sided p-values < 0.05 were considered significant.
RESULTS
One hundred thirty-two patients, 131 female and 1 male, (mean age 59 ± 10.6 years) remained in the final study cohort. Patients in the humor group remembered the radiologist's name better (85%/30%, P < .001), appreciated the final discussion with the radiologist more (4.67 ± 0.73-5;[5, 5] vs. 4.24 ± 1.1-5;[4, 5], P = .017), felt the radiologist was more empathetic (4.94 ± 0.24-5;[5, 5] vs.4.59 ± 0.64-5;[4, 5], P < .001), and rated him as a humorous doctor (4.91 ± 0.29-5;[5, 5] vs. 2.26 ± 1.43-1;[1, 4], P < .001). Additionally, patients in the humor group tended to experience less anxiety (p = 0.166) and felt the doctor was more competent (p = 0.094).
CONCLUSION
Humor during routine breast examinations may improve patient-radiologist relationship because the radiologist is considered more empathetic and competent, patients recall the radiologist's name more easily, and value the final discussion more.
TRIAL REGISTRATION
We have a general approval from our ethics committee because it is a retrospective survey, the patient lists for the doctors were anonymized and it is a qualitative study, since the clinical processes are part of the daily routine examinations and are used independently of the study. The patients have given their consent to this study and survey
Suction/Inspiration against resistance or standardized Mueller maneuver: a new breathing technique to improve contrast density within the pulmonary artery: a pilot CT study
Objective: Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. Material and methods: The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. Results: Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. Conclusion: Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. Key Points : • Suction/Inspiration against resistance is promising to improve contrast density within the pulmonary artery. • Patients potentially suffering pulmonary embolism are able to follow suction/inspiration against resistance. • Contrast density after suction is superior in comparison to other breathing maneuvers
Left Atrial Ejection Fraction Assessed by Prior Cardiac CT Predicts Recurrence of Atrial Fibrillation after Pulmonary Vein Isolation
Assuming that atrial fibrillation (AF) is associated with left atrial remodeling and dysfunction, we hypothesize that left atrial and left atrial appendage ejection fractions (LAEF and LAAEF) are useful and may be more sensitive outcome predictors of pulmonary vein isolation (PVI). Fifty patients who underwent PVI at our institution with available pre-interventional cardiac computed tomography (CT) for procedure planning were included in this retrospective study. The patients were separated into two groups by recurrence and non-recurrence of AF and subgroups of paroxysmal and persistent AF. Semiautomatic volumetric analysis of the left atrium was used to calculate morphological and functional parameters and optimal cut-offs were calculated using the Youden index. LAEF (accuracy 94%, sensitivity 67%) and LAAEF (accuracy 90%, sensitivity 67%) were significantly reduced in patients with AF recurrence (16% vs. 36%, p = 0.00002; 16% vs. 42%, p = 0.000002), and in the subgroup analysis, the functional parameters were independent from AF type (paroxysmal and persistent). With a cut-off of <23% for both LAEF and LAAEF (area under the curve (AUC) 0.94, 95%CI 0.84–0.99 and AUC 0.96, 95%CI 0.86–0.99, respectively), AF recurrence occurred in 77.8%, within a mean follow-up period of 229 days. In conclusion, left atrial function on prior cardiac CT offers useful parameters for predicting AF recurrence after PVI
Radiologic complete response (rCR) in contrast-enhanced magnetic resonance imaging (CE-MRI) after neoadjuvant chemotherapy for early breast cancer predicts recurrence-free survival but not pathologic complete response (pCR)
Abstract Background Patients with early breast cancer (EBC) achieving pathologic complete response (pCR) after neoadjuvant chemotherapy (NACT) have a favorable prognosis. Breast surgery might be avoided in patients in whom the presence of residual tumor can be ruled out with high confidence. Here, we investigated the diagnostic accuracy of contrast-enhanced MRI (CE-MRI) in predicting pCR and long-term outcome after NACT. Methods Patients with EBC, including patients with locally advanced disease, who had undergone CE-MRI after NACT, were retrospectively analyzed (n = 246). Three radiologists, blinded to clinicopathologic data, reevaluated all MRI scans regarding to the absence (radiologic complete remission; rCR) or presence (no-rCR) of residual contrast enhancement. Clinical and pathologic responses were compared categorically using Cohen’s kappa statistic. The Kaplan-Meier method was used to estimate recurrence-free survival (RFS) and overall survival (OS). Results Overall rCR and pCR (no invasive tumor in the breast and axilla (ypT0/is N0)) rates were 45% (111/246) and 29% (71/246), respectively. Only 48% (53/111; 95% CI 38–57%) of rCR corresponded to a pCR (= positive predictive value - PPV). Conversely, in 87% (117/135; 95% CI 79–92%) of patients, residual tumor observed on MRI was pathologically confirmed (= negative predictive value - NPV). Sensitivity to detect a pCR was 75% (53/71; 95% CI 63–84%), while specificity to detect residual tumor and accuracy were 67% (117/175; 95% CI 59–74%) and 69% (170/246; 95% CI 63–75%), respectively. The PPV was significantly lower in hormone-receptor (HR)-positive compared to HR-negative tumors (17/52 = 33% vs. 36/59 = 61%; P = 0.004). The concordance between rCR and pCR was low (Cohen’s kappa − 0.1), however in multivariate analysis both assessments were significantly associated with RFS (rCR P = 0.037; pCR P = 0.033) and OS (rCR P = 0.033; pCR P = 0.043). Conclusion Preoperative CE-MRI did not accurately predict pCR after NACT for EBC, especially not in HR-positive tumors. However, rCR was strongly associated with favorable RFS and OS
Bacterial contamination of ultrasound probes in different radiological institutions before and after specific hygiene training: do we have a general hygienical problem?
Objectives
Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places.
Methods
In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed.
Results
Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p < 0.001). Cultures taken from public places showed a median of 4 CFU from toilets and 28 from bus poles and had lower bacterial load in comparison to ultrasound probes before training (p = 0.055, toilets; p = 0.772, bus poles), without statistical significance.
Conclusions
Bacterial contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections.ISSN:0938-7994ISSN:1432-108