10,005 research outputs found

    Optimized stray-field-induced enhancement of the electron spin precession by buried Fe gates

    Full text link
    The magnetic stray field from Fe gates is used to modify the spin precession frequency of InGaAs/GaAs quantum-well electrons in an external magnetic field. By using an etching process to position the gates directly in the plane of the quantum well, the stray-field influence on the spin precession increases significantly compared with results from previous studies with top-gated structures. In line with numerical simulations, the stray-field-induced precession frequency increases as the gap between the ferromagnetic gates is reduced. The inhomogeneous stray field leads to additional spin dephasing.Comment: 4 pages, 2 figure

    Calcitonin gene-related peptide receptor antagonist BIBN 4096 BS for the acute treatment of migraine

    Get PDF
    Background: Calcitonin gene–related peptide (CGRP) may have a causative role in migraine. We therefore hypothesized that a CGRP-receptor antagonist might be effective in the treatment of migraine attacks. Methods: In an international, multicenter, double-blind, randomized clinical trial of BIBN 4096 BS, a highly specific and potent nonpeptide CGRP-receptor antagonist, 126 patients with migraine received one of the following: placebo or 0.25, 0.5, 1, 2.5, 5, or 10 mg of BIBN 4096 BS intravenously over a period of 10 minutes. A group-sequential adaptive treatment-assignment design was used to minimize the number of patients exposed. Results: The 2.5-mg dose was selected, with a response rate of 66 percent, as compared with 27 percent for placebo (P=0.001). The BIBN 4096 BS group as a whole had a response rate of 60 percent. Significant superiority over placebo was also observed with respect to most secondary end points: the pain-free rate at 2 hours; the rate of sustained response over a period of 24 hours; the rate of recurrence of headache; improvement in nausea, photophobia, phonophobia, and functional capacity; and the time to meaningful relief. An effect was apparent after 30 minutes and increased over the next few hours. The overall rate of adverse events was 25 percent after the 2.5-mg dose of the drug and 20 percent for the BIBN 4096 BS group as a whole, as compared with 12 percent for placebo. The most frequent side effect was paresthesia. There were no serious adverse events. Conclusions: The CGRP antagonist BIBN 4096 BS was effective in treating acute attacks of migraine

    Trapped ion mobility spectrometry and PASEF enable in-depth lipidomics from minimal sample amounts

    No full text
    A comprehensive characterization of the lipidome from limited starting material remains very challenging. Here we report a high-sensitivity lipidomics workflow based on nanoflow liquid chromatography and trapped ion mobility spectrometry (TIMS). Taking advantage of parallel accumulation-serial fragmentation (PASEF), we fragment on average 15 precursors in each of 100 ms TIMS scans, while maintaining the full mobility resolution of co-eluting isomers. The acquisition speed of over 100 Hz allows us to obtain MS/MS spectra of the vast majority of isotope patterns. Analyzing 1 mu L of human plasma, PASEF increases the number of identified lipids more than three times over standard TIMS-MS/MS, achieving attomole sensitivity. Building on high intra- and inter-laboratory precision and accuracy of TIMS collisional cross sections (CCS), we compile 1856 lipid CCS values from plasma, liver and cancer cells. Our study establishes PASEF in lipid analysis and paves the way for sensitive, ion mobility-enhanced lipidomics in four dimensions

    Incompatible Magnetic Order in Multiferroic Hexagonal DyMnO3

    Full text link
    Magnetic order of the manganese and rare-earth lattices according to different symmetry representations is observed in multiferroic hexagonal (h-) DyMnO3_3 by optical second harmonic generation and neutron diffraction. The incompatibility reveals that the 3d-4f coupling in the h-RRMnO3_3 system (RR = Sc, Y, In, Dy - Lu) is substantially less developed than commonly expected. As a consequence, magnetoelectric coupling effects in this type of split-order parameter multiferroic that were previously assigned to a pronounced 3d-4f coupling have now to be scrutinized with respect to their origin

    Komplexe proximale Humerusfraktur beim alten Menschen: Winkelstabile Plattenosteosynthese vs. Hemiarthroplastik

    Get PDF
    Zusammenfassung: Hintergrund: Ziel der vorliegenden Untersuchung ist ein direkter Vergleich der Schulterhemiarthroplastik (SHA) mit der winkelstabilen Plattenosteosynthese (WSPOS) beim alten Patienten mit komplexer proximaler Humerusfraktur. Patienten und Methoden: Zwischen 2003 und 2005 wurden alle Patienten (n=52, Alter ≥70Jahre) mit 3- und 4-Segment-Frakturen des proximalen Humerus, welche mit einer WSPOS (PHILOS®) versorgt wurden, prospektiv erfasst und nach einem Jahr mittels Constant-Score (CS), Oxford Shoulder Score (OSS) und radiologisch nachkontrolliert. Verglichen wurde die WSPOS mit einem historischen Kollektiv mit identischen Einschlusskriterien, welches zwischen 1995 und 1997 an der gleichen Institution mittels SHA versorgt wurde (n=59). Ergebnisse: Beide Patientenkollektive zeigten keine Unterschiede bezüglich Alter, Geschlechterverteilung und Frakturtypen. Der CS war signifikant besser für die WSPOS (median 71 vs. 41). Bezüglich Schmerzen zeigte sich im OSS kein Unterschied zwischen den Gruppen. In der WSPOS-Gruppe mussten signifikant mehr Revisionseingriffe durchgeführt werden (25% vs. 2%). Schlussfolgerung: Die WSPOS liefert beim alten Patienten, bei komplexen proximalen Humerusfrakturen deutlich bessere funktionelle Resultate, ist jedoch mit mehr Rezidiveingriffen behaftet. Die Selbständigkeit der Patienten kann bei beiden Operationsmethoden bei guter Schmerzfreiheit meist erhalten werde

    Second harmonic generation on incommensurate structures: The case of multiferroic MnWO4

    Full text link
    A comprehensive analysis of optical second harmonic generation (SHG) on an incommensurate (IC) magnetically ordered state is presented using multiferroic MnWO4 as model compound. Two fundamentally different SHG contributions coupling to the primary IC magnetic order or to secondary commensurate projections of the IC state, respectively, are distinguished. Whereas the latter can be described within the formalism of the 122 commensurate magnetic point groups the former involves a breakdown of the conventional macroscopic symmetry analysis because of its sensitivity to the lower symmetry of the local environment in a crystal lattice. Our analysis thus foreshadows the fusion of the hitherto disjunct fields of nonlinear optics and IC order in condensed-matter systems

    Compact Frontend-Electronics and Bidirectional 3.3 Gbps Optical Datalink for Fast Proportional Chamber Readout

    Get PDF
    The 9600 channels of the multi-wire proportional chamber of the H1 experiment at HERA have to be read out within 96 ns and made available to the trigger system. The tight spatial conditions at the rear end flange require a compact bidirectional readout electronics with minimal power consumption and dead material. A solution using 40 identical optical link modules, each transferring the trigger information with a physical rate of 4 x 832 Mbps via optical fibers, has been developed and commisioned. The analog pulses from the chamber can be monitored and the synchronization to the global HERA clock signal is ensured.Comment: 13 pages, 10 figure
    corecore