9,141 research outputs found

    Future Prospects for High Energy Polarimetry of Gamma‐Ray Bursts

    Get PDF
    The recent detection of linear polarization from GRB120206 has piqued the interest of the community in this relatively unexplored avenue of research. Here, we review the current status and prospects for GRB polarimetry at hard X‐ray and soft γ‐ray energies. After reviewing the most recent results, we present a brief survey of current and planned experiments that are capable of making GRB polarization measurements in the energy range between 30 keV and 30 MeV

    An overview of solar flare results from COMPTEL

    Get PDF
    The COMPTEL experiment on the Compton Gamma Ray Observatory (CGRO) has been operating in orbit since April of 1991. During that time, COMPTEL has observed several large flares, the most notable of which were several X‐class flares which took place in June of 1991. As a solar instrument, COMPTEL has the capability to measure solar flare radiation in two parallel observing modes. In its telescope mode, COMPTEL is capable of measuring both solar flare photons (in the 0.75–30 MeV range) and solar flare neutrons (in the 20–150 MeV range) using the double scatter technique with a field‐of‐view of ∌1 steradian. This approach also permits the imaging of the incident solar radiations (both photons and neutrons). The burst mode of COMPTEL utilizes two of the lower D2 detectors as large‐area spectroscopy detectors to provide additional data in the 0.6–10 MeV range. Here we shall review both modes of COMPTEL operation and provide an overview of solar flare results which are presently available

    GRAPE - A Balloon-Borne Gamma-Ray Polarimeter Experiment

    Full text link
    This paper reviews the development status of GRAPE (the Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We are particularly interested in X-rays that are emitted from solar flares and gamma-ray bursts (GRBs), although GRAPE could also be employed in the study of other astrophysical sources. Accurately measuring the polarization of the emitted radiation will lead to a better understating of both emission mechanisms and source geometries. The GRAPE design consists of an array of plastic scintillators surrounding a central high-Z crystal scintillator. The azimuthal distribution of photon scatters from the plastic array into the central calorimeter provides a measure of the polarization fraction and polarization angle of the incident radiation. The design of the detector provides sensitivity over a large field-of-view (>pi steradian). The design facilitates the fabrication of large area arrays with minimal deadspace. This paper presents the latest design concept and the most recent results from laboratory tests of a GRAPE science model.Comment: 6 pages; paper presented at the FRASCATI Workshop 2005 on Multifrequency Behaviour of High Energy Cosmic Sources; submitted to Chinese Journal of Astronomy and Astrophysic

    COMPTEL solar flare measurements

    Get PDF
    We review some of the highlights of the COMPTEL measurements of solar flares. These include images of the Sun in γ rays and neutrons. One of the important features of the COMPTEL instrument is its capability to measure weak fluxes of γ rays and neutrons in the extended phase of flares. These data complement the spectra taken with the COMPTEL burst spectrometer and the telescope during the impulsive phase of flares. We focus our attention on some of these general capabilities of the instrument and the latest results of two long‐duration γ‐ray flares, i.e., 11 and 15 June 199

    Energy shedding during nonlinear self-focusing of optical beams

    Get PDF
    Self-focusing of intense laser beams and pulses of light in real nonlinear media is in general accompanied by material losses that require corrections to the conservative Nonlinear Schrödinger equations describing their propagation. Here we examine loss mechanisms that exist even in lossless media and are caused by shedding of energy away from the self-trapping beam making it to relax to an exact solution of lower energy. Using the conservative NLS equations with absorbing boundary conditions we show that energy shedding not only occurs during the initial reshaping process but also during oscillatory propagation induced by saturation of the nonlinear effect. For pulsed input we also show that, depending on the sign and magnitude of dispersion, pulse splitting, energy shedding, collapse or stable self-focusing may result

    Recent laboratory tests of a hard x-ray solar flare polarimeter

    Get PDF
    We report on the development of a Compton scatter polarimeter for measuring the linear polarization of hard X-rays (50 - 300 keV) from solar flares. Such measurements would be useful for studying the directivity (or beaming) of the electrons that are accelerated in solar flares. We initially used a simple prototype polarimeter to successfully demonstrate the reliability of our Monte Carlo simulation code and to demonstrate our ability to generate a polarized photon source in the lab. We have recently fabricated a science model based on a modular design concept that places a self-contained polarimeter module on the front-end of a 5-inch position- sensitive PMT (PSPMT). The PSPMT is used to determine the Compton interaction location within an annular array of small plastic scintillator elements. Some of the photons that scatter within the plastic scintillator array are subsequently absorbed by a small centrally-located array of CsI(Tl) crystals that is read out by an independent multi-anode PMT. The independence of the two PMT readout schemes provides appropriate timing information for event triggering. We are currently testing this new polarimeter design in the laboratory to evaluate the performance characteristics of this design. Here we present the initial results from these laboratory tests. The modular nature of this design lends itself toward its accommodation on a balloon or spacecraft platform. A small array of such modules can provide a minimum detectable polarization (MDP) of less than 1% in the integrated 50 - 300 keV energy range for X-class solar flares

    Hard x-ray polarimeter for gamma-ray bursts and solar flares

    Get PDF
    We report on the development of a dedicated polarimeter design that is capable of studying the linear polarization of hard X-rays (50-300 keV) from gamma-ray bursts and solar flares. This compact design, based on the use of a large area position-sensitive PMT (PSPMT), is referred to as GRAPE (Gamma-RAy Polarimeter Experiment). The PSPMT is used to determine the Compton interaction location within an array of small plastic scintillator elements. Some of the photons that scatter within the plastic scintillator array are subsequently absorbed by a small centrally-located array of CsI(Tl) crystals that is read out by an independent multi-anode PMT. One feature of GRAPE that is especially attractive for studies of gamma-ray bursts is the significant off-axis response (at angles \u3e 60 degrees). The modular nature of this design lends itself toward its accomodation on a balloon or spacecraft platform. For an array of GRAPE modules, sensitivity levels below a few percent can be achieved for both gamma-ray bursts and solar flares. Here we report on the latest results from the testing of a laboratory science model

    U.S. jobs gained and lost through trade: a net measure

    Get PDF
    Recent concerns about the transfer of U.S. services jobs to overseas workers have deepened long-standing fears about the effects of trade on the domestic labor market. But a balanced view of the impact of trade requires that we consider jobs created through the production of U.S. exports as well as jobs lost to imports. A new measure of the jobs gained and lost in international trade flows suggests that the net number of U.S. jobs lost is relatively small-2.4 percent of total U.S. employment as of 2003.Labor market ; Exports ; International trade

    Dedicated polarimeter design for hard x-ray and soft gamma-ray astronomy

    Get PDF
    We have developed a modular design for a hard X-ray and soft gamma-ray polrimeter that we call GRAPE (Gamma RAy Polarimeter Experiment). Optimized for the energy range of 50-300 keV, the GRAPE design is a Compton polarimeter based on the use of an array of plastic scintillator scattering elements in conjunction with a centrally positioned high-Z calorimeter detector. Here we shall review the results from a laboratory model of the baseline GRAPE design. The baseline design uses a 5-inch diameter position sensitive PMT (PSPMT) for readout of the plastic scintillator array and a small array of CsI detectors for measurement of the scattered photon. An improved design, based on the use of large area multi-anode PMTs (MAPMTs), is also discussed along with plans for laboratory testing of a prototype. An array of GRAPE modules could be used as the basis for a dedicated science mission, either on a long duration balloon or on an orbital mission. With a large effective FoV, a non-imaging GRAPE mission would be ideal for studying polarization in transient sources (gamma ray bursts and solar flares). It may also prove useful for studying periodically varying sources, such as pulsars. An imaging system would improve the sensitivity of the polarization measurements for transient and periodic sources and may also permit the measurement of polarization in steady-state sources

    The Development of GRAPE, a Gamma Ray Polarimeter Experiment

    Get PDF
    The measurement of hard X‐ray polarization in γ‐ray bursts (GRBs) would add yet another piece of information in our effort to resolve the true nature of these enigmatic objects. Here we report on the development of a dedicated polarimeter design with a relatively large FoV that is capable of studying hard X‐ray polarization (50–300 keV) from GRBs. This compact design, based on the use of a large area position‐sensitive PMT (PSPMT), is referred to as GRAPE (Gamma‐RAy Polarimeter Experiment). The feature of GRAPE that is especially attractive for studies of GRBs is the significant off‐axis polarization response (at angles greater than 60°). For an array of GRAPE modules, current sensitivity estimates give minimum detectable polarization (MDP) levels of a few percent for the brightest GRBs
    • 

    corecore