13 research outputs found

    Assessment of flatness and symmetry of megavoltage x-ray beam with an electronic portal imaging device (EPID)

    Get PDF
    Copyright © 2002 ACPSEM. All rights reserved. The document attached has been archived with permission from the publisher.The input/output characteristics of the Wellhofer BIS 710 electronic portal imaging device (EPID) have been investigated to establish its efficacy for periodic quality assurance (QA) applications. Calibration curves have been determined for the energy fluence incident on the detector versus the pixel values. The effect of the charge coupled device (CCD) camera sampling time and beam parameters (such as beam field size, dose rate, photon energy) on the calibration have been investigated for a region of interest (ROI) around the central beam axis. The results demonstrate that the pixel output is a linear function of the incident exposure, as expected for a video-based electronic portal imaging system. The field size effects of the BIS 710 are similar to that of an ion chamber for smaller field sizes up to 10 x 10 cm2. However, for larger field sizes the pixel value increases more rapidly. Furthermore, the system is slightly sensitive to dose rate and is also energy dependent. The BIS 710 has been used in the current study to develop a QA procedure for measurements of flatness and symmetry of a linac x-ray beam. As a two-dimensional image of the radiation field is obtained from a single exposure of the BIS 710, a technique has been developed to calculate flatness and symmetry from a defined radiation area. The flatness and symmetry values obtained are different from those calculated conventionally from major axes only (inplane, crossplane). This demonstrates that the technique can pick up the "cold" and "hot" spots in the analysed area, providing thus more information about the radiation beam. When calibrated against the water tank measurements, the BIS 710 can be used as a secondary device to monitor the x-ray beam flatness and symmetry.G. Liu, T. van Doorn and E. Beza

    Cross-institutional knowledge-based planning (KBP) implementation and its performance comparison to Auto-Planning Engine (APE)

    No full text
    Item does not contain fulltextBACKGROUND AND PURPOSE: To investigate (1) whether a plan library established at one institution can be applied for another institution's knowledge-based planning (KBP); (2) the performance of cross-institutional KBP compared to Auto-Planning Engine (APE). MATERIAL AND METHODS: Radboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (68Gy to PTV68 and 50.3Gy to PTV50.3) with clinically-delivered and comparative APE plans. The Johns Hopkins University (JHU) contributed a three-dose-level plan library consisting of 179 clinically-delivered plans. MedStar Georgetown University Hospital (MGUH) contributed a KBP approach employing overlap-volume histogram (OVH-KBP), where the JHU library was used for guiding RUMC patients' KBP. Since clinical protocols adopted at RUMC and JHU are different and both approaches require protocol-specific planning parameters as initial input, 10 randomly selected patients from RUMC were set aside for deriving them. The finalized parameters were applied to the remaining 25 patients for OVH-KBP and APE plan generation. A Wilcoxon rank-sum test was used for statistical comparison. RESULTS: PTV68 and PTV50.3's V95 in OVH-KBP and APE were similar (p>0.36). Cord's D0.1 cc in OVH-KBP was reduced by 5.1Gy (p=0.0001); doses to other organs were similar (p>0.2). CONCLUSION: APE and OVH-KBP's plan quality is comparable. Institutional-protocol differences can be addressed to allow cross-institutional library sharing

    Kardiovaskuläre Pharmaka und körperliche Belastung

    No full text

    A Review of Low Frequency Electromagnetic Wave Phenomena Related to Tropospheric-Ionospheric Coupling Mechanisms

    No full text

    A Review of PCSK9 Inhibitors and their Effects on Cardiovascular Diseases

    No full text
    corecore