5,724 research outputs found

    Contaminant removal from enclosed atmospheres by regenerable adsorbents

    Get PDF
    A system for removing contaminants from spacecraft atmospheres was studied, which utilizes catalyst-impregnated activated carbon followed by in-situ regeneration by low-temperature catalytic oxidation of the adsorbed contaminants. Platinum was deposited on activated carbon by liquid phase impregnation with chloroplatinic acid, followed by drying and high-temperature reduction. Results were obtained for the seven selected spacecraft contaminants by means of three experimental test systems. The results indicate that the contaminants could be removed by oxidation with very little loss in adsorptive capacity. The advantages of a catalyst-impregnated carbon for oxidative regeneration are found to be significant enough to warrent its use

    Patient safety in undergraduate radiography curricula : a European perspective

    Get PDF
    Purpose: To establish an understanding of patient safety within radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiographer Societies (EFRS). Method: An online survey was developed to ascertain data on: programme type, patient safety definitions, relevant safety topics, specific areas taught, teaching and assessment methods, levels of teaching and curriculum drivers. Responses were identifiable in terms of educational institution and country. All 54 affiliated educational institutions were invited to participate. Descriptive and thematic analyses are reported. Results: A response rate of 61.1% (n = 33) was achieved from educational institutions representing 19 countries. Patient safety topics appear to be extremely well covered across curricula, however, topics including radiation protection and optimisation were not reported as being taught at an ‘advanced level’ by five and twelve respondents, respectively. Respondents identified the clinical department as the location of most patient safety-related teaching. Conclusions: Patient safety topics are deeply embedded within radiography curricula across Europe. Variations exist in terms of individual safety topics included, teaching and assessment methods, and the depth in which subjects are taught. Results from this study provide a baseline for assessing developments in curricula and can also serve as a benchmark for comparisons

    Evaluation of techniques for removal of spacecraft contaminants from activated carbon

    Get PDF
    Alternative techniques for the regeneration of carbon contaminated with various spacecraft contaminants were evaluated. Four different modes of regeneration were evaluated: (1) thermal desorption via vacuum, (2) thermal desorption via nitrogen purge, (3) in-situ catalytic oxidation of adsorbed contaminants, and (4) in-situ non-catalytic oxidation of adsorbed contaminants

    Prediction of larynx function using multichannel surface EMG classification

    Get PDF
    Total laryngectomy (TL) affects critical functions such as swallowing, coughing and speaking. An artificial, bioengineered larynx (ABL), operated via myoelectric signals, may improve quality of life for TL patients. To evaluate the efficacy of using surface electromyography (sEMG) as a control signal to predict instances of swallowing, coughing and speaking, sEMG was recorded from submental, intercostal and diaphragm muscles. The cohort included TL and control participants. Swallowing, coughing, speaking and movement actions were recorded, and a range of classifiers were investigated for prediction of these actions. Our algorithm achieved F1-scores of 76.0 ± 4.4 % (swallows), 93.8 ± 2.8 % (coughs) and 70.5 ± 5.4 % (speech) for controls, and 67.7 ± 4.4 % (swallows), 71.0 ± 9.1 % (coughs) and 78.0 ± 3.8 % (speech) for TLs, using a random forest (RF) classifier. 75.1 ± 6.9 % of swallows were detected within 500 ms of onset in the controls, and 63.1 ± 6.1 % in TLs. sEMG can be used to predict critical larynx movements, although a viable ABL requires improvements. Results are particularly encouraging as they encompass a TL cohort. An ABL could alleviate many challenges faced by laryngectomees. This study represents a promising step toward realising such a device

    Very preterm infants engage in an intervention to train their control of attention: results from the feasibility study of the Attention Control Training (ACT) randomised trial

    Get PDF
    Background Very premature birth (gestational age between 28 and 31 + 6 weeks) is associated with increased risk of cognitive delay and attention deficit disorder, which have been linked to anomalies in the development of executive functions (EFs) and their precursors. In particular, very preterm (VP) infants display anomalies in controlling attention and gathering task-relevant information. Early interventions that support attention control may be pivotal in providing a secure base for VP children’s later attainments. The Attention Control Training (ACT) is a cognitive training intervention that targets infants’ abilities to select visual information according to varying task demands but had not been tested in VP infants. We conducted a feasibility study to test the processes we intend to use in a trial delivering the ACT to VP infants. Methods and design We tested recruitment and retention of VP infants and their families in a randomised trial, as well as acceptability and completion of baseline and outcome measures. To evaluate these aims, we used descriptive quantitative statistics and qualitative methods to analyse feedback from infants’ caregivers. We also investigated the quality of eye-tracking data collected and indicators of infants’ engagement in the training, using descriptive statistics. Results Twelve VP infants were recruited, and 10 (83%) completed the study. Participants’ parents had high education attainment. The rate of completion of baseline and outcome measures was optimal. VP infants demonstrated engagement in the training, completing on average 84 min of training over three visits, and displaying improved performance during this training. Eye-tracking data quality was moderate, but this did not interfere with infants’ engagement in the training. Discussion The results suggest the ACT can be delivered to VP infants. However, challenges remain in recruitment of numerous and diverse samples. We discuss strategies to overcome these challenges informed by results of this study. Trial registration Registered Registration ID: NCT03896490. Retrospectively registered at Clinical Trials Protocol Registration and Results System (clinicaltrials.gov)

    Strain dependence of bonding and hybridization across the metal-insulator transition of VO2

    Full text link
    Soft x-ray spectroscopy is used to investigate the strain dependence of the metal-insulator transition of VO2. Changes in the strength of the V 3d - O 2p hybridization are observed across the transition, and are linked to the structural distortion. Furthermore, although the V-V dimerization is well-described by dynamical mean-field theory, the V-O hybridization is found to have an unexpectedly strong dependence on strain that is not predicted by band theory, emphasizing the relevance of the O ion to the physics of VO2

    Passive solid state microdosimeter with electronic readout

    Get PDF
    Apparatus and method for qualitatively and quantitatively analyzing a complex radiation field are provided. A passive microdosimetry detector device records the energy deposition of incident radiation using an array of microstructure non-volatile memory devices. Each microstructure non-volatile memory device is capable of storing a predetermined initial charge without requiring a power source. A radiation particle incident to a microstructure non-volatile memory device is termed an event . Each such event may generate a charge within a sensitive volume defined by the microstructure non-volatile memory device. The charge generated within the sensitive volume alters the stored initial charge by an amount falling within a range corresponding to the energy deposited by certain particle types. Data corresponding to such charge alterations for a plurality of microstructure non-volatile memory devices within an array of such devices are presented to a qualitative analyzing device. The qualitative analyzing device converts the data to a spectral analysis of the incident radiation field by applying ICRP-recommended weighting factors to individual events or approximations thereof

    Weak charge form factor and radius of 208Pb through parity violation in electron scattering

    Get PDF
    We use distorted wave electron scattering calculations to extract the weak charge form factor F_W(q), the weak charge radius R_W, and the point neutron radius R_n, of 208Pb from the PREX parity violating asymmetry measurement. The form factor is the Fourier transform of the weak charge density at the average momentum transfer q=0.475 fm−1^{-1}. We find F_W(q) =0.204 \pm 0.028 (exp) \pm 0.001 (model). We use the Helm model to infer the weak radius from F_W(q). We find R_W= 5.826 \pm 0.181 (exp) \pm 0.027 (model) fm. Here the exp error includes PREX statistical and systematic errors, while the model error describes the uncertainty in R_W from uncertainties in the surface thickness \sigma of the weak charge density. The weak radius is larger than the charge radius, implying a "weak charge skin" where the surface region is relatively enriched in weak charges compared to (electromagnetic) charges. We extract the point neutron radius R_n=5.751 \pm 0.175 (exp) \pm 0.026 (model) \pm 0.005 (strange) fm$, from R_W. Here there is only a very small error (strange) from possible strange quark contributions. We find R_n to be slightly smaller than R_W because of the nucleon's size. Finally, we find a neutron skin thickness of R_n-R_p=0.302\pm 0.175 (exp) \pm 0.026 (model) \pm 0.005 (strange) fm, where R_p is the point proton radius.Comment: 5 pages, 1 figure, published in Phys Rev. C. Only one change in this version: we have added one author, also to metadat
    • …
    corecore