385 research outputs found
Feasible Form Parameter Design of Complex Ship Hull Form Geometry
This thesis introduces a new methodology for robust form parameter design of complex hull form geometry via constraint programming, automatic differentiation, interval arithmetic, and truncated hierarchical B- splines. To date, there has been no clearly stated methodology for assuring consistency of general (equality and inequality) constraints across an entire geometric form parameter ship hull design space. In contrast, the method to be given here can be used to produce guaranteed narrowing of the design space, such that infeasible portions are eliminated. Furthermore, we can guarantee that any set of form parameters generated by our method will be self consistent. It is for this reason that we use the title feasible form parameter design.
In form parameter design, a design space is represented by a tuple of design parameters which are extended in each design space dimension. In this representation, a single feasible design is a consistent set of real valued parameters, one for every component of the design space tuple. Using the methodology to be given here, we pick out designs which consist of consistent parameters, narrowed to any desired precision up to that of the machine, even for equality constraints. Furthermore, the method is developed to enable the generation of complex hull forms using an extension of the basic rules idea to allow for automated generation of rules networks, plus the use of the truncated hierarchical B-splines, a wavelet-adaptive extension of standard B-splines and hierarchical B-splines. The adaptive resolution methods are employed in order to allow an automated program the freedom to generate complex B-spline representations of the geometry in a robust manner across multiple levels of detail. Thus two complementary objectives are pursued: ensuring feasible starting sets of form parameters, and enabling the generation of complex hull form geometry
Application of single cell transcriptomics to kinetoplastid research
Kinetoplastid parasites are responsible for both human and animal diseases across the globe where they have a great impact on health and economic well-being. Many species and life cycle stages are difficult to study due to limitations in isolation and culture, as well as to their existence as heterogeneous populations in hosts and vectors. Single-cell transcriptomics (scRNA-seq) has the capacity to overcome many of these difficulties, and can be leveraged to disentangle heterogeneous populations, highlight genes crucial for propagation through the life cycle, and enable detailed analysis of hostâparasite interactions. Here, we provide a review of studies that have applied scRNA-seq to protozoan parasites so far. In addition, we provide an overview of sample preparation and technology choice considerations when planning scRNA-seq experiments, as well as challenges faced when analysing the large amounts of data generated. Finally, we highlight areas of kinetoplastid research that could benefit from scRNA-seq technologies
The population genetic structure of the urchin Centrostephanus rodgersii in New Zealand with links to Australia
© The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2021Publishe
Recommended from our members
Individual and joint trajectories of change in bone, lean mass and physical performance in older men.
BackgroundDeclines in bone, muscle and physical performance are associated with adverse health outcomes in older adults. However, few studies have described concurrent age-related patterns of change in these factors. The purpose of this study was to characterize change in four properties of muscle, physical performance, and bone in a prospective cohort study of older men.MethodsUsing repeated longitudinal data from up to four visits across 6.9âyears from up to 4681 men (mean age at baseline 72.7âyrs. ±5.3) participating in the Osteoporotic Fractures in Men (MrOS) Study, we used group-based trajectory models (PROC TRAJ in SAS) to identify age-related patterns of change in four properties of muscle, physical performance, and bone: total hip bone mineral (BMD) density (g/m2) and appendicular lean mass/ht2 (kg/m2), by DXA; grip strength (kg), by hand dynamometry; and walking speed (m/s), by usual walking pace over 6âm. We also described joint trajectories in all pair-wise combinations of these measures. Mean posterior probabilities of placement in each trajectory (or joint membership in latent groups) were used to assess internal reliability of the model. The number of trajectories for each individual factor was limited to three, to ensure that the pair-wise determination of joint trajectories would yield a tractable number of groups as well as model fit considerations.ResultsThe patterns of change identified were generally similar for all measures, with three district groups declining over time at roughly similar rates; joint trajectories revealed similar patterns with no cross-over or convergence between groups. Mean posterior probabilities for all trajectories were similar and consistently above 0.8 indicating reasonable model fit to the data.ConclusionsOur description of trajectories of change with age in bone mineral density, grip strength, walking speed and appendicular lean mass found that groups identified by these methods appeared to have little crossover or convergence of change with age, even when considering joint trajectories of change in these factors
Quantitative assessment of renal structural and functional changes in chronic kidney disease using multi-parametric magnetic resonance imaging
BACKGROUND:Multi-parametric magnetic resonance imaging (MRI) provides the potential for a more comprehensive non-invasive assessment of organ structure and function than individual MRI measures, but has not previously been comprehensively evaluated in chronic kidney disease (CKD).METHODS:We performed multi-parametric renal MRI in persons with CKD (nâ=â22, 61â±â24 years) who had a renal biopsy and measured glomerular filtration rate (mGFR), and matched healthy volunteers (HV) (nâ=â22, 61â±â25 years). Longitudinal relaxation time (T1), diffusion-weighted imaging, renal blood flow (phase contrast MRI), cortical perfusion (arterial spin labelling) and blood-oxygen-level-dependent relaxation rate (R2*) were evaluated.RESULTS:MRI evidenced excellent reproducibility in CKD (coefficient of variation
Synthesis of novel thieno[3,2-b]thienobis(silolothiophene) based low bandgap polymers for organic photovoltaics
Thieno[3,2-b]thienobis(silolothiophene), a new electron rich hexacyclic monomer has been synthesized and incorporated into three novel donorâacceptor low-bandgap polymers. By carefully choosing the acceptor co-monomer, the energy levels of the polymers could be modulated and high power conversion efficiencies of 5.52% were reached in OPV devices
Direct three-dimensional printing of polymeric scaffolds with nanofibrous topography
Three-dimensional (3D) printing is a powerful manufacturing tool for making 3D structures with well-defined architectures for a wide range of applications. The field of tissue engineering has also adopted this technology to fabricate scaffolds for tissue regeneration. The ability to control architecture of scaffolds, e.g. matching anatomical shapes and having defined pore size, has since been improved significantly. However, the material surface of these scaffolds is smooth and does not resemble that found in natural extracellular matrix (ECM), in particular, the nanofibrous morphology of collagen. This natural nanoscale morphology plays a critical role in cell behaviour. Here, we have developed a new approach to directly fabricate polymeric scaffolds with an ECM-like nanofibrous topography and defined architectures using extrusion-based 3D printing. 3D printed tall scaffolds with interconnected pores were created with disparate features spanning from nanometres to centimetres. Our approach removes the need for a sacrificial mould and subsequent mould removal compared to previous methods. Moreover, the nanofibrous topography of the 3D printed scaffolds significantly enhanced protein absorption, cell adhesion and differentiation of human mesenchymal stem cells (MSCs) when compared to those with smooth material surfaces. These 3D printed scaffolds with both defined architectures and nanoscale ECM-mimicking morphologies have potential applications in cartilage and bone regeneration
Disc Motor: Conventional and Superconductor Simulated Results Analysis
International audienceTaking into consideration the development and integration of electrical machines with lower dimensions and higher performance, this paper presents the design and development of a three-phase axial flux disc motor, with 50 Hz frequency supply. It is made with two conventional semi-stators and a rotor, which can be implemented with a conventional aluminum disc or a high temperature-superconducting disc. The analysis of the motor characteristics is done with a 2D commercial finite elements package, being the modeling performed as a linear motor. The obtained results allow concluding that the superconductor motor provides a higher force than the conventional one. The conventional disc motor presents an asynchronous behavior, like a conventional induction motor, while the superconductor motor presents both synchronous and asynchronous behaviors
- âŠ