1,268 research outputs found

    Open or Endovascular Repair of Secondary Aortoenteric Fistulae?

    Get PDF

    Integral-field studies of the high-redshift Universe

    Full text link
    We present results from a new method of exploring the distant Universe. We use 3-D spectroscopy to sample a large cosmological volume at a time when the Universe was less than 3 billion years old to investigate the evolution of star-formation activity. Within this study we also discovered a high redshift type-II quasar which would not have been identified with imaging studies alone. This highlights the crucial role that integral-field spectroscopy may play in surveying the distant Universe in the future.Comment: From proceedings of Euro3D Spectroscopy annual RTN network meeting (ed. J. Walsh). 5 pages, accepted for publication in Astron. Nach

    Monitoring 3D vibrations in structures using high resolution blurred imagery

    Get PDF
    This thesis describes the development of a measurement system for monitoring dynamic tests of civil engineering structures using long exposure motion blurred images, named LEMBI monitoring. Photogrammetry has in the past been used to monitor the static properties of laboratory samples and full-scale structures using multiple image sensors. Detecting vibrations during dynamic structural tests conventionally depends on high-speed cameras, often resulting in lower image resolutions and reduced accuracy. To overcome this limitation, the novel and radically different approach presented in this thesis has been established to take measurements from blurred images in long-exposure photos. The motion of the structure is captured in an individual motion-blurred image, alleviating the dependence on imaging speed. A bespoke algorithm is devised to determine the motion amplitude and direction of each measurement point. Utilising photogrammetric techniques, a model structure s motion with respect to different excitations is captured and its vibration envelope recreated in 3D, using the methodology developed in this thesis. The approach is tested and used to identify changes in the model s vibration response, which in turn can be related to the presence of damage or any other structural modification. The approach is also demonstrated by recording the vibration envelope of larger case studies in 2D, which includes a full-scale bridge structure, confirming the relevance of the proposed measurement approach to real civil engineering case studies. This thesis then assesses the accuracy of the measurement approach in controlled motion tests. Considerations in the design of a survey using the LEMBI approach are discussed and limitations are described. The implications of the newly developed monitoring approach to structural testing are reviewed

    Is Infrainguinal Bypass Grafting Successful Following Failed Angioplasty?

    Get PDF
    ObjectivesAngioplasty is often used in the management of lower limb ischaemia and can reduce the need for infrainguinal bypass in some patients. There is an associated failure rate with this technique and bypass surgery is often used in this situation as a secondary limb salvage procedure. We aimed to evaluate the outcome of infrainguinal bypass grafting following failed attempt at angioplasty.MethodsAll cases of infrainguinal bypass at a single centre over a seven year period were identified and notes reviewed. Cases were divided into four groups according to their indication for surgery; acute ischaemia, chronic critical ischaemia, failed angioplasty and an ‘other’ group including aneurysmal disease and claudicants. The failed angioplasty group was compared with the other three groups. Survival analysis was performed using Kaplan Meier curves and groups compared in terms of long term patency and survival.ResultsPrimary patency was 61.2% in the failed angioplasty group at 12 months compared with 60.6% in the other groups (P=1.11). There was also no significant difference in primary patency at 60 months (50% vs 40.6%, P=0.26). Survival at 12 months was also comparable between the groups (failed angioplasty group 74.2% compared with 77.3% in the other groups, P=0.662) as was 60 months survival (33.3% and 35.4% respectively, P=0.166).DiscussionIn this study, outcome of infrainguinal bypass following failed angioplasty was comparable to outcome of surgery performed for another indication. This paper supports the use of distal bypass surgery for limb salvage in cases where minimal access techniques have failed

    At what peak velocity ratio value should duplex-detected infrainguinal vein graft stenoses be revised?

    Get PDF
    Objectives:To determine the peak velocity ratio (PVR) threshold at which to intervene and correct duplex detected vein graft stenoses.Design:Prospective study.Materials:Infrainguinal vein grafts in patients attending the vascular studies for routine postoperative surveillance.Methods:Colour duplex detected stenotic vein graft lesions with a peak velocity ratio (PVR) between 2.0 and 2.9 were identified and monitored by serial duplex scans performed monthly for 3 months and then at 3-monthly intervals thereafter. At the end of the study period, the outcome of these lesions were analysed.Results:Thirty-eight lesions were identified from 32 grafts. Of these lesions, sixteen (42%) resolved, 11 (29%) remained stable and 11 (29%) progressed to a PVR of ≥3.0 and underwent angioplasty. There were no occlusions in any of the grafts during the period of study.Conclusion:Colour duplex detected vein graft stenoses with a PVR of less than 3.0 can be treated expectantly if grafts with stenoses with a PVR 2.0–2.9 are scanned every month for at least 3 months after detection

    3-D case studies of monitoring dynamic structural tests using long exposure imagery

    Get PDF
    Structural health monitoring uses non-destructive testing programmes to detect long-term degradation phenomena in civil engineering structures. Structural testing may also be carried out to assess a structure’s integrity following a potentially damaging event. Such investigations are increasingly carried out with vibration techniques, in which the structural response to artificial or natural excitations is recorded and analysed from a number of monitoring locations. Photogrammetry is of particular interest here since a very high number of monitoring locations can be measured using just a few images. To achieve the necessary imaging frequency to capture the vibration, it has been necessary to reduce the image resolution at the cost of spatial measurement accuracy. Even specialist sensors are limited by a compromise between sensor resolution and imaging frequency. To alleviate this compromise, a different approach has been developed and is described in this paper. Instead of using high-speed imaging to capture the instantaneous position at each epoch, long-exposure images are instead used, in which the localised image of the object becomes blurred. The approach has been extended to create 3D displacement vectors for each target point via multiple camera locations, which allows the simultaneous detection of transverse and torsional mode shapes. The proposed approach is frequency invariant allowing monitoring of higher modal frequencies irrespective of a sampling frequency. Since there is no requirement for imaging frequency, a higher image resolution is possible for the most accurate spatial measurement. The results of a small scale laboratory test using off-the-shelf consumer cameras are demonstrated. A larger experiment also demonstrates the scalability of the approach

    Bilateral infrainguinal vein grafts and the incidence of vein graft stenosis

    Get PDF
    Objectives:To elucidate the incidence of significant vein graft stenosis in patients who have undergone bilateral infrainguinal vein grafts.Materials:Between 1987 and 1996, 22 patients were identified from our vascular studies database as having undergone bilateral infrainguinal vein bypass grafting.Methods:Data was obtained from the vascular studies database and by case note review. All patients had been part of a vein graft surveillance programme.Results:Of the 22 patients with bilateral vein grafts, eight were excluded from further analysis because one or more of their grafts failed within 30 postoperative days. In the remaining 14 patients (28 vein grafts) there were 15 primary vein graft stenoses. Six patients (43%) had bilateral vein graft stenoses, which is significantly higher (p = 0.0008) than the predicted value of 9%, for developing bilateral vein graft stenoses. For those patients who developed a vein graft stenosis in their first grafted limb (9/14), 67% (6/14) subsequently developed a vein graft stenosis in their second grafted limb.Conclusion:Patients who develop vein graft stenosis in one limb are at a greater risk of developing a contralateral vein graft stenosis if that limb is grafted. This may well be due to individual vein morphology or unidentified systemic factors that play a role in the aetiology of vein graft stenosis

    Nitrogen transformations differentially affect nutrient-limited primary production in lakes of varying trophic state

    Get PDF
    The concept of lakes “evolving” phosphorus (P) limitation has persisted in limnology despite limited direct evidence. Here, we developed a simple model to broadly characterize nitrogen (N) surpluses and deficits, relative to P, in lakes and compared the magnitude of this imbalance to estimates of N gains and losses through biological N transformations. The model suggested that approximately half of oligotrophic lakes in the U.S.A. had a stoichiometric N deficit, but 72–89% of eutrophic and hypereutrophic lakes, respectively, had a similar N deficit. Although reactive N appeared to accumulate in the most oligotrophic lakes, net denitrification perpetuated the N deficit in more productive lakes. Productive lakes exported reactive N via biological N transformations regardless of their N deficit. The lack of N accumulation through N fixation underscores the need for a modern eutrophication management approach focused on reducing total external nutrient loads, including both N and P

    Broadly tunable all-solid-state picosecond LBO optical parametric oscillator

    No full text
    We report a synchronously-pumped optical parametric oscillator with a tuning range of 0.72-1.91µm, average output powers up to 89mW and pulse durations of 1.5psec

    Stable isotope signatures reveal small-scale spatial separation in populations of European sea bass

    Get PDF
    Scientific information about European sea bass (Dicentrarchus labrax) stocks in NE Atlantic is limited and a more accurate definition of the stock boundaries in the area is required to improve assessment and management advice. Here we study the connectivity and movement patterns of European sea bass in Wales (UK) using the stable isotope (δ13C and δ15N) composition of their scales. Analysis of fish scale δ13C and δ15N values in the last growing season was performed on 189 adult sea bass caught at nine coastal feeding grounds. Fish >50 cm total length (TL) caught in estuaries had very low δ13C and this is characteristic of fresh water (organic/soil) input, indicating the primary use of estuaries as feeding areas. A random forest classification model was used to test if there was a difference in δ15N and δ13C values between north, mid and south Wales and whether it was possible to correctly assign the fish to the area where it was caught. This analysis was restricted to fish of a similar size range (40-50 cm TL) caught in open coastal areas (n=156). The random forest classification model showed that about 75% of the fish could be correctly assigned to their collection region based on their isotope composition. The majority of the misclassifications of fish were fish from north Wales classifying to mid Wales and vice versa, while the majority of fish from south Wales were correctly assigned (80%). Our findings suggest that two sub-populations of sea bass in Welsh waters use separate feeding grounds (south vs. mid/north Wales), and may need separate management
    corecore