54 research outputs found

    Sports Activity After Short-Stem Hip Arthroplasty

    Get PDF
    Background: No data are available about the sports activity of patients with bone-conserving short-stem hip implants. Hypothesis: Patients can return to a good level of sports activity after implantation of a short-stem hip implant. Study Design: Case series; Level of evidence, 4. Methods: The sports activity level of 68 patients (76 hips) after short-stem hip arthroplasty was assessed for a minimum of 2 years after implantation. In addition to the clinical examination, a detailed evaluation of the patients’ sports pattern was obtained. Furthermore, the results were analyzed with regard to gender (female and male) and age (55 years). Results: After a mean of 2.7 years, patients showed a Harris Hip Score (HHS) of 93.6, a Western Ontario and McMaster Universities Arthritis Index (WOMAC) score of 9.5, and a University of California, Los Angeles (UCLA) activity score of 7.6, with each individual participating on average in 3.5 different disciplines after surgery compared with 3.9 before surgery. High-impact activities decreased significantly postoperatively, whereas low-impact activities increased significantly. The duration of the sports activities remained stable, while the frequency actually increased. In contrast, men participated preoperatively in more sports than women (4.3 men vs 3.3 women). However, because of a pronounced decrease in high-impact activities by men, both genders participated in an equal number of sports postoperatively (3.5 men vs 3.5 women). Finally, 45% (n = 31) reported at least one activity that they missed. Most of them were disciplines with an intermediate- or high-impact level. Conclusion: Patients with a short-stem hip implant can return to a good level of activity postoperatively. Participation in sports almost reached similar levels as preoperatively but with a shift from high- to low-impact activities. This seems desirable from a surgeon’s point of view but should also be communicated to the patient before hip replacemen

    Revision of hip resurfacing arthroplasty with a bone-conserving short-stem implant: a case report and review of the literature

    Get PDF
    Introduction Suitable treatment of early failure of total hip replacement is critical in younger patients, as bone stock is lost and the functional outcome is impaired. Case presentation We report the case of a 56-year-old Caucasian woman with early failure of hip resurfacing arthroplasty. While revision is usually performed with a conventional hip implant, this case report describes for the first time a revision procedure with a bone-conserving short-stem hip implant. Conclusions Our approach allows further conservation of femoral bone stock and provides a long-term solution to the patient, which maintains the possibility of using a conventional hip implant should a second revision become necessary

    Patients with Intolerance Reactions to Total Knee Replacement: Combined Assessment of Allergy Diagnostics, Periprosthetic Histology, and Peri-implant Cytokine Expression Pattern

    Get PDF
    We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR): patch test (PT), lymphocyte transformation test (LTT), histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils), and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFN gamma, TNF alpha, IL1-beta, IL-2, IL-6, IL-8, IL-10, IL17, and TGF beta). We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions;9 with only LTT reactivity). Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane) tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFN gamma expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies

    Die Biegestabprothese: ein experimenteller Ansatz zur metaphysären Hüftendoprothetik

    Get PDF
    The aim of our study was to develop a femoral component for total hip arthroplasty that would exclusively anchor in the metaphysis of the femoral neck. To forego trochanteric fixation, the load needs to be transferred to the metaphysis at as many points as possible. A computer simulation model suggested that an implant with a central cylinder and 16 rods aligned along a thread would be the preferable solution. To evaluate primary implantation stability, 14 fresh frozen cadaver femora were used. A special instrument set was developed to allow for centered implantation of the prosthesis without the need to dissect the greater trochanter. For our tests, we used two prototype implants: one made from titanium and the other from a CoCrMo alloy. For the measurement of micromotions at the medial proximal femur, sinusoid dynamic loading with a force between 300 N and 1700 N and a frequency of 1 Hz was employed. In a neutral position of 16 degrees adduction and 9 degrees ante-torsion, the average micronnotions measured were 119 mu m. Despite these convincing in vitro results with regards to primary stability, circular cut-out of the implant, followed by aseptic osteonecrosis, loosening might still occur in a clinical situation. Animal experiments are therefore required to further evaluate this new implant design

    Minimally Invasive Surgical Approaches and Traditional Total Hip Arthroplasty: A Meta-Analysis of Radiological and Complications Outcomes

    Get PDF
    BACKGROUND: Minimally invasive total hip arthroplasty (MITHA) remains considerably controversial. Limited visibility and prosthesis malposition increase the risk of post-surgical complications compared to those of the traditional method. METHODS: A meta-analysis was undertaken of all published databases up to May 2011. The studies were divided into four subgroups according to the surgical approach taken. The radiological outcomes and complications of minimally invasive surgery were compared to traditional total hip arthroplasty (TTHA) using risk ratio, mean difference, and standardized mean difference statistics. RESULTS: In five studies involving the posterolateral approach, no significant differences were found between the MITHA groups and the TTHA groups in the acetabular cup abduction angle (p = 0.41), acetabular anteversion (p = 0.96), and femoral prosthesis position (p = 0.83). However, the femoral offset was significantly increased (WMD = 3.00; 95% CI, 0.40-5.60; p = 0.02). Additionally, there were no significant differences among the complications in both the groups (dislocations, nerve injury, infection, deep vein thrombosis, proximal femoral fracture) and revision rate (p>0.05). In three studies involving the posterior approach, there were no significant differences in radiological outcomes or all other complications between MITHA or TTHA groups (p>0.05). Three studies involved anterolateral approach, while 2 studies used the lateral approach. However, the information from imaging and complications was not adequate for statistical analysis. CONCLUSIONS: Posterior MITHA seems to be a safe surgical procedure, without the increased risk of post-operative complication rates and component malposition rates. The posterolateral approach THA may lead to increased femoral offset. The current data are not enough to reach a positive conclusion that lateral and anterolateral approaches will result in increased risks of adverse effects and complications at the prosthesis site

    Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    Get PDF
    ABSTRACT: BACKGROUND: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. METHODS: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. RESULTS: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. CONCLUSIONS: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis

    Prognostische Faktoren zur Beurteilung der Wertigkeit der ASK bei Gonarthrose

    No full text

    The effect of FADS2 gene rs174583 polymorphism on desaturase activities, fatty acid profile, insulin resistance, biochemical indices, and incidence of type 2 diabetes

    No full text
    Background: In this study, we investigated the associations of erythrocytes fatty acid composition, activities of delta-5 desaturase (D5D) and delta-6 desaturase (D6D), and other metabolic risk factors, with type 2 diabetes (T2D) risk to determine if rs174583 polymorphism of FADS2 gene had any effect on these associations. Materials and Methods: Fatty acid profile of erythrocytes was determined using gas chromatography-mass spectrometry in 95 T2D patients and 95 apparently healthy participants. The genotypes of single-nucleotide polymorphism (SNP) of FADS2 gene were determined using the polymerase chain reaction-restriction fragment length polymorphism technique. Other biochemical parameters were measured in the serum using standard analytical procedures. Results: D6D activity was increased (P < 0.001) and D5D activity was decreased in T2D patients (P < 0.001) compared to controls. Homeostatic model assessment insulin resistance (HOMA-IR) index was positively correlated with D6D (r = 0.34, P < 0.001) and negatively correlated with D5D (r = −0.19, P = 0.02). Palmitic acid (P < 0.001) and dihomo-gamma-linolenic acid (P = 0.03) were higher and linoleic acid (P < 0.001) and arachidonic acid (AA) (P < 0.001) were lower in T2D patients. The distribution of rs174583 genotypes which includes C/T, C/C, and T/T was not different in the two groups (P = 0.63). Conclusion: In the population studied, there was a strong association in the erythrocytes fatty acid composition, D5D and D6D activities and other metabolic risk factors between non-T2D and T2D patients. In addition, there was a strong association in erythrocytes DGLA and AA contents and D5D activities between rs174583 genotypes in all participants. However, the distribution of rs174583 genotypes did not differ significantly between T2D patient and controls, and it did not appear to be an association between rs174583 SNP and incident of T2D

    Der Sinn oder Unsinn der Kniearthroskopie bei Arthrose

    No full text

    Metallionen-Messung im Serum, Urin und Erythrozyten bei Oberflächenersatz am Hüftgelenk

    No full text
    • …
    corecore