5,479 research outputs found

    Triple covers and a non-simply connected surface spanning an elongated tetrahedron and beating the cone

    Full text link
    By using a suitable triple cover we show how to possibly model the construction of a minimal surface with positive genus spanning all six edges of a tetrahedron, working in the space of BV functions and interpreting the film as the boundary of a Caccioppoli set in the covering space. After a question raised by R. Hardt in the late 1980's, it seems common opinion that an area-minimizing surface of this sort does not exist for a regular tetrahedron, although a proof of this fact is still missing. In this paper we show that there exists a surface of positive genus spanning the boundary of an elongated tetrahedron and having area strictly less than the area of the conic surface.Comment: Expanding on the previous version with additional lower bounds, new images, corrections and improvements. Comparison with Reifenberg approac

    CP violation in D meson decays: would it be a sign of new physics ?

    Get PDF
    Ascribing the large SU(3) violations in the Cabibbo forbidden decays of neutral D mesons to the final state interactions, one gets large strong phase differences, necessary for substantial direct CP violation. While the absolute value of the CP violating asymmetries depend on the uncertain strength of the penguin contribution, we predict an asymmetry for the decays into charged pions more than twice as large and having opposite sign with respect to that for charged kaons.Comment: 9 pages, added references, minor changes in the text, results unchanged. Accepted for publication in Physical Review

    Characterization of FBK small-pitch 3D diodes after neutron irradiation up to 3.5x10**16 neq cm**-2

    Full text link
    We report on the characterization by a position resolved laser system of small-pitch 3D diodes irradiated with neutrons up to an extremely high fluence of 3.5x10**16 neq cm**-2. We show that very high values of signal efficiency are obtained, in good agreement with the geometrical expectation based on the small values of the inter-electrode spacings, and also boosted by charge multiplication effects at high voltage. These results confirm the very high radiation tolerance of small-pitch 3D sensors well beyond the maximum fluences expected at the High Luminosity LHC.Comment: 10 pages, 7 figures, submitted to Proceedings of IWORID 2018 on JINS

    Interleaving Command Sequences: a Threat to Secure Smartcard Interoperability

    Full text link
    The increasingly widespread use of smartcards for a variety of sensitive applications, including digital signatures, creates the need to ensure and possibly certify the secure interoperability of these devices. Standard certification criteria, in particular the Common Criteria, define security requirements but do not sufficiently address the problem of interoperability. Here we consider the interoperability problem which arises when various applications interact with different smartcards through a middleware. In such a situation it is possible that a smartcard of type S receives commands that were supposed to be executed on a different smartcard of type S'. Such "external commands" can interleave with the commands that were supposed to be executed on S. We experimentally demonstrate this problem with a Common Criteria certified digital signature process on a commercially available smartcard. Importantly, in some of these cases the digital signature processes terminate without generating an error message or warning to the user.Comment: 6 pages; published in the 10th WSEAS International Conference on Information Security and Privacy (ISP 2011

    Reverse shoulder prosthesis in patients with rheumatoid arthritis: a systematic review

    Get PDF
    PURPOSE: To obtain detailed information on the outcomes of patients with rheumatoid arthritis (RA) undergoing reverse shoulder arthroplasty (RSA) METHODS: A literature search was conducted for studies reporting on the use of RSA in RA patients from 1990 to 2014. The inclusion criteria were a report of sufficient information on pre-operative status and surgical outcome allowing evaluation of the therapeutic potential of RSA in RA. The literature search resulted in 586 hits, but only five studies that met the inclusion criteria were assessed. RESULTS: There were 100 shoulders that had been operated on, of which 87 were followed for a mean of 55.4 months, the longest follow-up being 11.9 years Most patients had glenohumeral erosive lesions of Larsen Grade III or IV. The Delta III prosthesis was implanted in most cases and in three studies bone graft was used for severe glenoid lesions. The main outcome measures employed were the Constant score (Cs) and ASES questionnaire. The mean increase in Cs and ASES score after surgery was 42.4 and 54 points, respectively. The mean post-operative forward elevation was 120.6°, the average increment being 51° and the mean increase of abduction was 58.5°. The mean prevalence of scapular notching was 35.4 %. The rate of adverse events was 31 %, but the vast majority were of minor severity. Eight prostheses underwent revision, due to infection in four. CONCLUSIONS: RSA implanted in RA patients would appear to give similar results to those obtained in massive cuff tears with or without arthropathy

    A novel technique of contrast-enhanced optical coherence tomography imaging in evaluation of clearance of lipids in human tears

    Get PDF
    Purpose: The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Methods: Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. Results: The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. Conclusions: This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach

    Development of New 3D Pixel Sensors for Phase 2 Upgrades at LHC

    Full text link
    We report on the development of new 3D pixel sensors for the Phase 2 Upgrades at the High-Luminosity LHC (HL-LHC). To cope with the requirements of increased pixel granularity (e.g., 50x50 or 25x100 um2 pixel size) and extreme radiation hardness (up to a fluence of 2e16 neq cm-2), thinner 3D sensors (~100 um) with electrodes having narrower size (~ 5 um) and reduced spacing (~ 30 um) are considered. The paper covers TCAD simulations, as well as technological and design aspects relevant to the first batch of these 3D sensors, that is currently being fabricated at FBK on 6-inch wafers.Comment: 4 pages, 8 figures, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conferenc

    The Global Electroweak and Higgs Fits in the LHC era

    Full text link
    We update the global fit to electroweak precision observables, including the effect of the latest measurements at hadron colliders of the WW and top-quark masses and the effective leptonic weak mixing angle. We comment on the impact of these measurements in terms of constraints on new physics. We also update the bounds derived from the fit to the Higgs-boson signal strengths, including the observables measured at the LHC Run 2, and compare the improvements with respect to the 7 and 8 TeV results.Comment: 5+1 pages, 3 figures, 2 tables. Prepared for the Proceedings of the 5th LHCP Conference -Shanghai, May 2017- and the EPS-HEP 2017 Conference -Venice, July 2017. (LHCP version.
    • …
    corecore