64 research outputs found

    Kleben statt nähen – in Zukunft eine Alternative für offene Bulbusverletzungen?

    Get PDF
    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N-isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injurie

    The epidemiology of uveal melanoma in Germany: a nationwide report of incidence and survival between 2009 and 2015

    Get PDF
    Purpose: To calculate the overall incidence of uveal melanoma in Germany and to compare incidences in different German states. In addition, we computed the overall and cancer-specific survival rates nationwide. Methods: Incidence data for the period between 2009 and 2015, covering the entire German population, was collected through the German Center for Cancer Registry. ICD-O-3 topography codes C69.3-C69.4 and histology codes for melanoma subtypes were used to collect the incidence data. Confidence Intervals with a level of 95% (95% CI) were calculated for rates. Survival was calculated using the Kaplan–Meier. The log-rank test was used for survival comparisons. Results: This study comprised 3654 patients with uveal melanomas, including 467 (12.8%) with iridial and ciliary body tumors. The overall age-standardized incidence rate (ASIR) was 6.41 person per million. Generally, the ASIR was higher in males than females (6.67 (95% CI 6.37–6.98) vs. 6.16 (95% CI 5.88–6.45 per million). Higher crude incidence rates were noted in the northeastern states (12.5 per million (95% CI 10.5–14.7) in Mecklenburg-Vorpommern) compared with the southwestern states (2.1 per million (95% CI 1.7–2.6) in Hessen). The 5-year overall survival stood at 47%, while the cancer-specific survival stood at 84%. Multivariate analysis showed that women, younger patients, and patients living in Berlin achieved significantly higher overall survival. Conclusion: Overall ASIR of uveal melanoma in Germany indicates that the disease is more common in males and that it follows the same geographical distribution previously noted in central European countries, with the highest incidence in northern parts of Germany

    Descemet membrane endothelial keratoplasty (DMEK) improves vision-related quality of life.

    Get PDF
    PURPOSE To evaluate vision-related quality of life (VRQL) before and after Descemet membrane endothelial keratoplasty (DMEK). METHODS The study was conducted in patients with Fuchs endothelial dystrophy or pseudophakic bullous keratopathy undergoing DMEK alone or in combination with cataract surgery (triple-DMEK) between August 2019 and March 2020 at the University of Leipzig Medical Center. Best-corrected visual acuity (BCVA) was measured. Visual acuity factor (VAF) and glare factor (GF) scores were calculated using the Visual Function and Corneal Health Status Instrument questionnaire answered by patients before surgery and 6 months thereafter. Subgroup analyses were performed for DMEK versus triple-DMEK, and for first versus second eyes, in addition to correlation analyses of scores with preoperative BCVA. RESULTS Forty-six patients were included in this analysis. VAF score improved from 0.68 ± 0.54 to 0.02 ± 0.57 (P < 0.0001) and GF score improved from 0.53 ± 0.43 to -0.11 ± 0.39 (P < 0.0001) during follow-up. Both scores improved without significant differences after surgery in the first and in the fellow eye (P < 0.0001) and after DMEK and triple-DMEK (P < 0.0001). The improvement of scores did not correlate with preoperative BCVA (r = 0.06, P = 0.68 for VAF; r =  -0.09, P = 0.54 for GF). CONCLUSION VRQL improves similarly after DMEK and triple-DMEK and between first and second operated eye. The extent of improvement is independent of the preoperative BCVA. The results of this study can be useful when planning DMEK by enabling a prediction of anticipated VRQL gain

    Retinometer predicts visual outcome in Descemet membrane endothelial keratoplasty.

    Get PDF
    PURPOSE To analyze the preoperative predictive value of retinometer visual acuity (VA) in eyes following Descemet membrane endothelial keratoplasty (DMEK). METHODS Patients undergoing DMEK between August 2011 and July 2020 were included. Preoperative interference visual acuity was assessed using Heine Lambda 100 Retinometer. Depending on the presence or absence of concomitant ocular disease, the Retinometer was evaluated for its ability to preoperatively predict best-corrected visual acuity (BCVA) six months after surgery using correlation, simple and multiple linear regression, contingency analyses, and receiver operating characteristic (ROC) analysis. Preoperative corneal backscatter was correlated with Retinometer prediction accuracy. RESULTS A total of 198 eyes were included in the analysis. There was a significant correlation between Retinometer VA and postoperative BCVA (r = 0.647, P < 0.001). Regardless of the presence or absence of concomitant ocular disease and the surgery procedure (DMEK & triple DMEK), Retinometer VA was the most significant predictor of postoperative BCVA (P < 0.001). ROC analysis revealed reliable diagnostic performance of the Retinometer (AUC = 0.829, P < 0.001). A Retinometer VA ≥ 0.5 accurately predicted a postoperative BCVA ≥ 0.5 in 91% of cases. No association was found between corneal backscatter and prediction accuracy (P = 0.566). CONCLUSIONS Retinometer VA can be used for preoperative prediction of postoperative BCVA in DMEK and triple DMEK patients, independent of increased backscatter values and the presence or absence of concomitant ocular disease. By using this simple but effective tool, indication for DMEK can be facilitated and postoperative outcomes can be realistically predicted preoperatively

    Different responses of the MIO‑M1 Mueller cell line to angiotensin II under hyperglycemic or hypoxic conditions.

    Get PDF
    Members of the renin-angiotensin aldosterone system (RAAS) are expressed by various retinal tissues including Mueller glial cells. As the RAAS is hypothesized to play an important role in the pathogenesis of diseases that threaten vision, such as diabetic macular edema or retinal vein occlusion, the possible changes induced by exposure of the human cell line MIO-M1, an established model of Mueller cells, to angiotensin II or aldosterone for 6 h under hypoxic and/or hyperglycemic conditions were investigated. The mRNA expression levels of the members of the RAAS were assessed by reverse transcription-quantitative PCR, and the secretion of cytokines was assessed by ELISA. Under hyperglycemic conditions, the mRNA expression levels of the angiotensin-converting enzyme 2 (ACE2), angiotensin II receptors, AT1 and AT2, and the receptor of angiotensin (1-7) MAS1 were significantly higher after exposure to angiotensin II, and the expression of ACE2, AT2, and IL-6 (a marker of inflammation) was significantly increased after treatment with aldosterone; the expression of the other targets investigated remained unchanged. Significantly more IL-6 was secreted by MIO-M1 cells exposed to hyperglycemia and angiotensin. When cells were cultured in a hypoxic environment, additional treatment with aldosterone significantly increased the mRNA expression levels of ACE, but significantly more ACE2 mRNA was expressed in the presence of angiotensin II. Under hypoxic plus hyperglycemic conditions, significantly less ACE but more AT2 was expressed after treatment with angiotensin II, which also led to strongly elevated expression of IL-6. The mRNA expression levels of the angiogenic growth factor VEGF-A and secretion of the encoded protein were notably increased under hypoxic and hypoxic plus hyperglycemic conditions, irrespective of additional treatment with angiotensin II or aldosterone. These findings suggest that angiotensin II induces a pro-inflammatory response in MIO-M1 cells under hyperglycemic conditions despite activation of the counteracting ACE2/MAS1 signaling cascade. However, hypoxia results in an increased expression of angiogenic VEGF-A by these cells, which is not altered by angiotensin II or aldosterone

    Refractive Changes after Glaucoma Surgery-A Comparison between Trabeculectomy and XEN Microstent Implantation.

    Get PDF
    Best-corrected visual acuity often decreases temporarily or permanently after trabeculectomy (TE). The purpose of this study was to compare visual acuity and refractive changes after TE or XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) or pseudoexfoliation glaucoma (PEX) cases naïve to prior glaucoma surgery over a 24-month follow-up period. We analyzed 149 consecutive glaucoma patients who received either TE or XEN because of medically uncontrollable POAG or PEX. Intraocular pressure (IOP), IOP-lowering medication use, subjective and objective refraction and best-corrected visual acuity were evaluated. In addition, surgically induced astigmatism (SIA) was calculated and compared using the vector analysis method described by Jaffe and Clayman. A total of 93 eyes (85 POAG; 8 PEX) were treated with TE and 56 eyes (50 POAG; 6 PEX) with XEN. After 24 months, the mean IOP and number of IOP-lowering medications used decreased significantly after TE (p &lt; 0.01) and XEN (p &lt; 0.01). In the TE group, mean best-corrected visual acuity (BCVA) changed from 0.16 ± 0.26 to 0.23 ± 0.28 logMAR (p &lt; 0.01) after 24 months, while mean BCVA did not change significantly in the XEN group (preoperative: 0.40 ± 0.50 logMAR, postoperative: 0.36 ± 0.49 logMAR; p = 0.28). SIA was almost the same in both groups at the end of the 24-month follow-up period (0.75 ± 0.60 diopters after TE and 0.81 ± 0.56 diopters after XEN; p = 0.57). In addition, there was no significant correlation between SIA and the observed BCVA changes or SIA and IOP reduction 12 or 24 months after TE or XEN. Our results demonstrate that TE and XEN are effective methods for reducing IOP and IOP-lowering medication use. The SIA was nearly similar in both groups. The SIA does not seem responsible for the decreased visual acuity after TE

    Functional Monitoring after Trabeculectomy or XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography and Visual Field Indices—A Retrospective Comparative Cohort Study

    Get PDF
    The aim of this study was to compare the efficacy of trabeculectomy (TE), single XEN microstent implantation (solo XEN) or combined XEN implantation and cataract surgery (combined XEN) in primary open-angle glaucoma cases, naïve to prior surgical treatment, using a monocentric retrospective comparative cohort study. Intraocular pressure (IOP) and the number of IOP-lowering drugs (Meds) were monitored during the first 24 months after surgery. Further disease progression was monitored using peripapillary retinal nerve fiber layer (RNFL) thickness examinations using spectral domain optical coherence tomography (OCT) as well as visual acuity (VA) and visual field (VF) tests. In the TE group (52 eyes), the mean IOP decreased from 24.9 ± 5.9 to 13.9 ± 4.2 mmHg (p < 0.001) and Meds decreased from 3.2 ± 1.2 to 0.5 ± 1.1 (p < 0.001). In the solo XEN (38 eyes) and the combined XEN groups, the mean IOP decreased from 24.1 ± 4.7 to 15.7 ± 3.0 mmHg (p < 0.001) and 25.4 ± 5.6 to 14.7 ± 3.2 mmHg (p < 0.001), while Meds decreased from 3.3 ± 0.8 to 0.8 ± 1.2 (p < 0.001) and 2.7 ± 1.2 to 0.4 ± 1.0 (p < 0.001), respectively. The VF and VA indices showed no sign of further deterioration, the RNFL thickness further decreased in all treatment groups after surgery. TE and XEN led to comparable reductions in IOP and Meds. Although the VA and VF indices remained unaltered, the RNFL thickness continuously decreased in all treatment groups during the 24-month follow-up

    Two Year Functional and Structural Changes-A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography.

    Get PDF
    The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, who received a TE or XEN for medically uncontrolled POAG. Intraocular pressure (IOP), amount of IOP-lowering medication, mean deviation of standard automated perimetry and peripapillary RNFL thickness were evaluated during the first 24 months after surgery. Fifty eyes were treated with TE and 69 eyes with XEN. Mean IOP decreased from 25.1 ± 0.8 to 13.3 ± 0.6 mm Hg (p &lt; 0.01) and mean number of IOP-lowering eye drops from 3.2 ± 0.2 to 0.4 ± 0.1 (p &lt; 0.01) 24 months after TE. In 69 eyes undergoing XEN, mean IOP dropped from 24.8 ± 0.6 to 15.0 ± 0.4 mm Hg (p &lt; 0.01) and medication from 3.0 ± 0.1 to 0.6 ± 0.1 (p &lt; 0.01) during the 24 months follow-up. Mean deviation of standard automated perimetry remained stable in TE (8.5 ± 0.7 to 8.1 ± 0.8 dB; p = 0.54) and XEN group (11,0 ± 0.5 to 11.5 ± 0.5 dB; p = 0.12) after 24 months, while mean RNFL thickness further deteriorated in the TE (-2.28 ± 0.65 µm/year) and XEN (-0.68 ± 0.34 µm/year) group. Postoperative RNFL loss develops after TE and XEN despite effective and significant lowering of IOP and amount of IOP-lowering medication. RNFL loss was more pronounced in the first year after glaucoma surgery

    Prognostic Factors in Patients with Persistent Full-Thickness Idiopathic Macular Holes Treated with Re-Vitrectomy with Autologous Platelet Concentrate

    Get PDF
    Purpose: To identify the predictors for anatomical and functional outcome after re-vitrectomy with application of autologous platelet concentrate (APC) in eyes with persistent idiopathic macular hole (MH). Methods: Retrospective study of 103 eyes with persistent MHs after vitrectomy with peeling of internal limiting membrane (ILM) and expansive gas. All patients underwent re-vitrectomy with APC and endotamponade. The anatomical MH closure rate and postoperative best-corrected visual acuity (BCVA) were evaluated. Further, predictive factors influencing the success of the surgery were analyzed. Results: Median BCVA (logMAR) before the surgery was 1.00 (interquartile range [IQR] 0.80–1.30) and the median of minimum diameter between hole edges was 508 μm (IQR 387–631). The final closure rate after re-vitrectomy with APC was 60.2% (62 of 103 eyes). The following predictors were identified to significantly influence the closure rate: tractional hole index (THI), axial length, time between first and second surgery, and the experience of the surgeon (p < 0.05). Conclusions: Re-vitrectomy with APC led to the closure of 60.2% of the persistent MHs. The closure rate negatively correlates with increasing axial length, time between the first and second surgery, and the decreased THI. Further, experienced surgeons (with a history of > 100 pars plana vitrectomies with ILM peeling) had significantly higher closure rates

    Intraocular Pressure Changes After Intravitreal Fluocinolone Acetonide Implant: Results from Four European Countries

    Get PDF
    none14siIntroduction: The 0.19 mg fluocinolone acetonide (FAc) intravitreal implant delivers a continuous intravitreal corticosteroid dose for the treatment of refractory diabetic macular oedema (DMO). The aim of this study was to assess the impact of an FAc intravitreal implant on intraocular pressure (IOP). Methods: We retrospectively collected anonymised data on the patients’ characteristics, DMO treatment, and IOP and IOP-lowering treatments before and after the FAc intravitreal implant between September 2013 and March 2020 in several European centres. Results: A total of 221 eyes from 179 patients were included. The mean follow-up duration was 13.4 (± 12.5, range 2.4–33.5) months. Overall, 194 eyes (88.2%) had received an intravitreal dexamethasone injection before the FAc intravitreal implant. For 25 eyes (11.3%) there was a history of glaucoma, and 52 eyes (23.5%) had previous IOP-lowering treatment. Mean IOP before injection was 14.7 (3.4) mmHg and increased to 16.9 (3.7) mmHg 12 months after injection (P < 0.0001). During follow-up, 55 eyes (24.9%) required the addition or initiation of topical IOP-lowering medication, only one patient (0.5%) had laser trabeculoplasty and one patient (0.5%) a minimally invasive glaucoma surgery, and no patient required incisional IOP-lowering surgery. Conclusion: The FAc intravitreal implant led to substantial IOP elevation. This elevation was monitored most of the time with addition or initiation of topical IOP-lowering medication.openLebrize S.; Arnould L.; Bourredjem A.; Busch C.; Rehak M.; Massin P.; Barbosa-Breda J.; Lupidi M.; Mariotti C.; Hamza M.; Grise-Dulac A.; Gabrielle P.-H.; Baillif S.; Creuzot-Garcher C.Lebrize, S.; Arnould, L.; Bourredjem, A.; Busch, C.; Rehak, M.; Massin, P.; Barbosa-Breda, J.; Lupidi, M.; Mariotti, C.; Hamza, M.; Grise-Dulac, A.; Gabrielle, P. -H.; Baillif, S.; Creuzot-Garcher, C
    • …
    corecore