7 research outputs found

    Xanthomatous Hypophysitis Mimicking a Pituitary Adenoma: Case Report and Review of the Literature

    Get PDF
    Background. Hypophysitis is an inflammatory disease of the pituitary gland that may mimic pituitary tumors clinically and radiologically. Case Description. We report a case of a xanthomatous hypophysitis initially diagnosed as pituitary adenoma. A 31-year-old woman presented with headache, diabetes insipidus, and amenorrhea. A head CT scan showed no intrasellar changes, while an MRI scan showed a sellar cystic mass. An endocrinological work up revealed mild hypocortisolism and diabetes insipidus (DI). Transsphenoidal surgery was performed. The intraoperative histological examination suggested a pituitary adenoma. The removed tissue showed central necrosis surrounded by accumulation of foamy cells and xanthomatous epithelioid cells. The patient made an uneventful postoperative recovery, Nevertheless, DI persisted and the adenohypophysis hypofunction did not recover. Conclusion. We describe an unusual inflammatory lesion of the pituitary gland mimicking an adenoma. A high level of clinical suspicion of inflammatory disorders is necessary for correct diagnosis and optimal management

    The Drift Chamber detector of the FOOT experiment: Performance analysis and external calibration

    No full text
    The study that we present is part of the preparation work for the setup of the FOOT (FragmentatiOn Of Target) experiment whose main goal is the measurement of the double differential cross sections of fragments produced in nuclear interactions of particles with energies relevant for particle therapy. The present work is focused on the characterization of the gas-filled drift chamber detector composed of 36 sensitive cells, distributed over two perpendicular views. Each view consists of six consecutive and staggered layers with three cells per layer. We investigated the detector efficiency and we performed an external calibration of the space–time relations at the level of single cells. This information was then used to evaluate the drift chamber resolution. An external tracking system realized with microstrip silicon detectors was adopted to have a track measurement independent on the drift chamber. The characterization was performed with a proton beam at the energies of 228 and 80 MeV. The overall hit detection efficiency of the drift chamber has been found to be 0.929±0.008 , independent on the proton beam energy. The spatial resolution in the central part of the cell is about 150±10 μ m and 300±10 μ m and the corresponding detector angular resolution has been measured to be 1.62±0.16 mrad and 2.1±0.4 mrad for the higher and lower beam energies, respectively. In addition, the best value on the intrinsic drift chamber resolution has been evaluated to be in the range 60−100 μ m. In the framework of the FOOT experiment, the drift chamber will be adopted in the pre-target region, and will be exploited to measure the projectile direction and position, as well as for the identification of pre-target fragmentation events

    Characterization of 150 μm\mu m thick silicon microstrip prototype for the FOOT experiment

    No full text
    International audienceThe goals of the FOOT (FragmentatiOn Of Target) experiment are to measure the proton double differential fragmentation cross-section on H, C, O targets at beam energies of interest for hadrontherapy (50–250 MeV for protons and 50–400 MeV/u for carbon ions), and also at higher energy, up to 1 GeV/u for radioprotection in space. Given the short range of the fragments, an inverse kinematic approach has been chosen, requiring precise tracking capabilities for charged particles. One of the subsystems designed for the experiment will be the MSD (Microstrip Silicon Detector), consisting of three x-y measurement planes, each one made by two single sided silicon microstrip sensors. In this document, we will present a detailed description of the first MSD prototype assembly, developed by INFN Perugia group and the subsequent characterization of the detector performance. The prototype is a wide area(∼ 100 cm2^{2}) single sensor, 150 μm thick to reduce material budget and fragmentation probability along the beam path, with 50 μm strip pitch and 2 floating strip readout approach. The pitch adapter to connect strips with the readout channels of the ASIC has been implemented directly on the silicon surface. Beside the interest for the FOOT experiment, the results in terms of cluster signal, signal-to-noise ratio, dynamic range of the readout chips, as well as long-term stability studies in terms of noise, are relevant also for other experiments where the use of thin sensors is crucial

    Characterization of 150 μm thick silicon microstrip prototype for the FOOT experiment

    No full text
    International audienceThe goals of the FOOT (FragmentatiOn Of Target) experiment are to measure the proton double differential fragmentation cross-section on H, C, O targets at beam energies of interest for hadrontherapy (50–250 MeV for protons and 50–400 MeV/u for carbon ions), and also at higher energy, up to 1 GeV/u for radioprotection in space. Given the short range of the fragments, an inverse kinematic approach has been chosen, requiring precise tracking capabilities for charged particles. One of the subsystems designed for the experiment will be the MSD (Microstrip Silicon Detector), consisting of three x-y measurement planes, each one made by two single sided silicon microstrip sensors. In this document, we will present a detailed description of the first MSD prototype assembly, developed by INFN Perugia group and the subsequent characterization of the detector performance. The prototype is a wide area(∼ 100 cm2^{2}) single sensor, 150 μm thick to reduce material budget and fragmentation probability along the beam path, with 50 μm strip pitch and 2 floating strip readout approach. The pitch adapter to connect strips with the readout channels of the ASIC has been implemented directly on the silicon surface. Beside the interest for the FOOT experiment, the results in terms of cluster signal, signal-to-noise ratio, dynamic range of the readout chips, as well as long-term stability studies in terms of noise, are relevant also for other experiments where the use of thin sensors is crucial

    Correction to: Tocilizumab for patients with COVID-19 pneumonia. The single-arm TOCIVID-19 prospective trial

    No full text
    corecore