269 research outputs found

    Conspicuity and muscle-invasiveness assessment for bladder cancer using VI-RADS: a multi-reader, contrast-free MRI study to determine optimal b-values for diffusion-weighted imaging

    Get PDF
    To (1) compare bladder cancer (BC) muscle invasiveness among three b-values using a contrast-free approach based on Vesical Imaging-Reporting and Data System (VI-RADS), to (2) determine if muscle-invasiveness assessment is affected by the reader experience, and to (3) compare BC conspicuity among three b-values, qualitatively and quantitatively

    Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence

    Get PDF
    Background: Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. While TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. Objectives: To investigate sensitivity, specificity and predictive value of cardiac CT angigography (cCTA), cardiac MRI (CMR), and TTE for recurrence in patients with suspected cardioembolic stroke. Methods: We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMR (n=75) or cCTA (n=76) between January 2013 and May 2017. We evaluated for presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end-point was stroke recurrence. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for recurrent stroke were calculated; the diagnostic accuracy of CMR, cCTA, and TTE was compared between and within groups using area under the curves (AUCs). Results: Twelve and 14 recurrent strokes occurred in the cCTA and CMR groups, respectively. Sensitivity, specificity, PPV and NPV were: 33.3%, 93.7%, 50.0%, and 88.2% for cCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMR; 14.3%, 83.6%, 16.7%, 80.9% for TTE in the CMR group, and 8.3%, 93.7%, 20.0% and 84.5% for TTE in the cCTA group. Accuracy was not different (p>0.05) between cCTA (0.63, 95% CI [0.49, 0.77]), CMR (0.53, [0.42, 0.63]), TTE in CMR group (0.51, [0.40, 0.61], and TTE in cCTA group (0.51, [0.42, 0.59]). In cCTA group, atrial and ventricular thrombus were detected by cCTA in 3 patients and TTE in 1 patient; in CMR group, thrombus was detected by CMR in 1 patient and TTE in 2 patients. Conclusion: cCTA, CMR, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. cCTA and CMR may be valid alternatives to TTE. cCTA may be preferred given potentially better detection of atrial and ventricular thrombus. Clinical impact: cCTA and CMR have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings

    Rituximab Unveils Hypogammaglobulinemia and Immunodeficiency in Children with Autoimmune Cytopenia

    Get PDF
    BACKGROUND: Rituximab (RTX; anti-CD20 mAb) is a treatment option in children with refractory immune thrombocytopenia, autoimmune hemolytic anemia (AHA), and Evans syndrome (ES). Prevalence and clinical course of RTX-induced hypogammaglobulinemia in these patients are poorly known. OBJECTIVE: To evaluate the prevalence and risk factors for persistent hypogammaglobulinemia (PH) after RTX use. METHODS: Clinical and immunologic data from children treated with RTX for immune thrombocytopenia, AHA, and ES were collected from 16 Italian centers and 1 UK center at pre-RTX time point (0), +6 months, and yearly, up to 4 years post-RTX. Patients with previously diagnosed malignancy or primary immune deficiency (PID) were excluded. RESULTS: We analyzed 53 children treated with RTX for immune thrombocytopenia (n = 36), AHA (n = 13), and ES (n = 4). Median follow-up was 30 months (range, 12-48). Thirty-two percent of patients (17 of 53) experienced PH, defined as IgG levels less than 2 SD for age at last follow-up (>12 months after RTX). Significantly delayed B-cell recovery was observed in children experiencing PH (hazard ratio, 0.55; P < .05), and 6 of 17 (35%) patients had unresolved B-cell lymphopenia at last follow-up. PH was associated with IgA and IgM deficiency, younger age at RTX use (51 vs 116 months; P < .01), a diagnosis of AHA/ES, and better response to RTX. Nine patients with PH (9 of 17 [53%]) were eventually diagnosed with a PID. CONCLUSIONS: Post-RTX PH is a frequent condition in children with autoimmune cytopenia; a sizable proportion of patients with post-RTX PH were eventually diagnosed with a PID. In-depth investigation for PID is therefore recommended in these patients

    No improvement of survival with reduced- versus high-intensity conditioning for allogeneic stem cell transplants in Ewing tumor patients

    Get PDF
    Background: Outcomes of Ewing tumor (ET) patients treated with allogeneic stem cell transplantation (allo-SCT) were compared regarding the use of reduced-intensity conditioning (RIC) and high-intensity conditioning (HIC) regimens as well as human leukocyte antigen (HLA)-matched and HLA-mismatched grafts. Patients and methods: We retrospectively analyzed data of 87 ET patients from the European Group for Blood and Marrow Transplantation, Pediatric Registry for Stem Cell Transplantations, Asia Pacific Blood and Marrow Transplantation and MetaEICESS registries treated with allo-SCT. Fifty patients received RIC (group A) and 37 patients received HIC (group B). Twenty-four patients received HLA-mismatched grafts and 63 received HLA-matched grafts. Results: Median overall survival was 7.9 months [±1.24, 95% confidence interval (CI) 5.44-10.31] for group A and 4.4 months (±1.06, 95% CI 2.29-6.43) for group B patients (P = 1.3). Death of complications (DOC) occurred in 4 of 50 (0.08) and death of disease (DOD) in 33 of 50 (0.66) group A and in 16 of 37 (0.43) and 17 of 37 (0.46) group B patients, respectively. DOC incidence was decreased (P < 0.01) and DOD/relapse increased (P < 0.01) in group A compared with group B. HLA mismatch was not generally associated with graft-versus-Ewing tumor effect (GvETE). Conclusions: There was no improvement of survival with RIC compared with HIC due to increased DOD/relapse incidence after RIC despite less DOC incidence. This implicates general absence of a clinically relevant GvETE with current protocol

    Registry of Aortic Diseases to Model Adverse Events and Progression (ROADMAP) in Uncomplicated Type B Aortic Dissection: Study Design and Rationale

    Full text link
    PURPOSE To describe the design and methodological approach of a multicenter, retrospective study to externally validate a clinical and imaging-based model for predicting the risk of late adverse events in patients with initially uncomplicated type B aortic dissection (uTBAD). MATERIALS AND METHODS The Registry of Aortic Diseases to Model Adverse Events and Progression (ROADMAP) is a collaboration between 10 academic aortic centers in North America and Europe. Two centers have previously developed and internally validated a recently developed risk prediction model. Clinical and imaging data from eight ROADMAP centers will be used for external validation. Patients with uTBAD who survived the initial hospitalization between January 1, 2001, and December 31, 2013, with follow-up until 2020, will be retrospectively identified. Clinical and imaging data from the index hospitalization and all follow-up encounters will be collected at each center and transferred to the coordinating center for analysis. Baseline and follow-up CT scans will be evaluated by cardiovascular imaging experts using a standardized technique. RESULTS The primary end point is the occurrence of late adverse events, defined as aneurysm formation (≄6 cm), rapid expansion of the aorta (≄1 cm/y), fatal or nonfatal aortic rupture, new refractory pain, uncontrollable hypertension, and organ or limb malperfusion. The previously derived multivariable model will be externally validated by using Cox proportional hazards regression modeling. CONCLUSION This study will show whether a recent clinical and imaging-based risk prediction model for patients with uTBAD can be generalized to a larger population, which is an important step toward individualized risk stratification and therapy.Keywords: CT Angiography, Vascular, Aorta, Dissection, Outcomes Analysis, Aortic Dissection, MRI, TEVAR© RSNA, 2022See also the commentary by Rajiah in this issue

    The Power Board of the KM3NeT Digital Optical Module: design, upgrade, and production

    Full text link
    The KM3NeT Collaboration is building an underwater neutrino observatory at the bottom of the Mediterranean Sea consisting of two neutrino telescopes, both composed of a three-dimensional array of light detectors, known as digital optical modules. Each digital optical module contains a set of 31 three inch photomultiplier tubes distributed over the surface of a 0.44 m diameter pressure-resistant glass sphere. The module includes also calibration instruments and electronics for power, readout and data acquisition. The power board was developed to supply power to all the elements of the digital optical module. The design of the power board began in 2013, and several prototypes were produced and tested. After an exhaustive validation process in various laboratories within the KM3NeT Collaboration, a mass production batch began, resulting in the construction of over 1200 power boards so far. These boards were integrated in the digital optical modules that have already been produced and deployed, 828 until October 2023. In 2017, an upgrade of the power board, to increase reliability and efficiency, was initiated. After the validation of a pre-production series, a production batch of 800 upgraded boards is currently underway. This paper describes the design, architecture, upgrade, validation, and production of the power board, including the reliability studies and tests conducted to ensure the safe operation at the bottom of the Mediterranean Sea throughout the observatory's lifespa

    KM3NeT broadcast optical data transport system

    Get PDF
    The optical data transport system of the KM3NeT neutrino telescope at the bottom of the Mediterranean Sea will provide more than 6000 optical modules in the detector arrays with a point-to-point optical connection to the control stations onshore. The ARCA and ORCA detectors of KM3NeT are being installed at a depth of about 3500 m and 2500 m, respectively and their distance to the control stations is about 100 kilometers and 40 kilometers. In particular, the two detectors are optimised for the detection of cosmic neutrinos with energies above about 1 TeV (ARCA) and for the detection of atmospheric neutrinos with energies in the range 1 GeV-1 TeV (ORCA). The expected maximum data rate is 200 Mbps per optical module. The implemented optical data transport system matches the layouts of the networks of electro-optical cables and junction boxes in the deep sea. For efficient use of the fibres in the system the technology of Dense Wavelength Division Multiplexing is applied. The performance of the optical system in terms of measured bit error rates, optical budget are presented. The next steps in the implementation of the system are also discussed

    Embedded Software of the KM3NeT Central Logic Board

    Full text link
    The KM3NeT Collaboration is building and operating two deep sea neutrino telescopes at the bottom of the Mediterranean Sea. The telescopes consist of latices of photomultiplier tubes housed in pressure-resistant glass spheres, called digital optical modules and arranged in vertical detection units. The two main scientific goals are the determination of the neutrino mass ordering and the discovery and observation of high-energy neutrino sources in the Universe. Neutrinos are detected via the Cherenkov light, which is induced by charged particles originated in neutrino interactions. The photomultiplier tubes convert the Cherenkov light into electrical signals that are acquired and timestamped by the acquisition electronics. Each optical module houses the acquisition electronics for collecting and timestamping the photomultiplier signals with one nanosecond accuracy. Once finished, the two telescopes will have installed more than six thousand optical acquisition nodes, completing one of the more complex networks in the world in terms of operation and synchronization. The embedded software running in the acquisition nodes has been designed to provide a framework that will operate with different hardware versions and functionalities. The hardware will not be accessible once in operation, which complicates the embedded software architecture. The embedded software provides a set of tools to facilitate remote manageability of the deployed hardware, including safe reconfiguration of the firmware. This paper presents the architecture and the techniques, methods and implementation of the embedded software running in the acquisition nodes of the KM3NeT neutrino telescopes
    • 

    corecore