112 research outputs found

    Unexplained cardiac arrest after near drowning in a young experienced swimmer: insight from cardiovascular magnetic resonance imaging

    Get PDF
    Cardiac magnetic resonance imaging (cMRI) is a well-established noninvasive imaging modality in clinical cardiology. Its ability to provide tissue characterization make it well suited for the study of patients with cardiac diseases. We describe a multi-modality imaging evaluation of a 45-year-old man who experienced a near drowning event during swimming. We underline the unique capability of tissue characterization provided by cMRI, which allowed detection of subtle, clinically unrecognizable myocardial damage for understanding the causes of sudden cardiac arrest and also showed the small damages caused by cardiopulmonary resuscitation

    Low-dose coronary calcium scoring CT using a dedicated reconstruction filter for kV-independent calcium measurements

    Get PDF
    In this prospective, pilot study, we tested a kV-independent coronary artery calcium scoring CT protocol, using a novel reconstruction kernel (Sa36f). From December 2018 to November 2019, we performed an additional research scan in 61 patients undergoing clinical calcium scanning. For the standard protocol (120 kVp), images were reconstructed with a standard, medium-sharp kernel (Qr36d). For the research protocol (automated kVp selection), images were reconstructed with a novel kernel (Sa36f). Research scans were sequentially performed using a higher (cohort A, n = 31) and a lower (cohort B, n = 30) dose optimizer setting within the automatic system with customizable kV selection. Agatston scores, coronary calcium volumes, and radiation exposure of the standard and research protocol were compared. A phantom study was conducted to determine inter-scan variability. There was excellent correlation for the Agatston score between the two protocols (r = 0.99); however, the standard protocol resulted in slightly higher Agatston scores (29.4 [0-139.0] vs 17.4 [0-158.2], p = 0.028). The median calcium volumes were similar (11.5 [0-109.2] vs 11.2 [0-118.0] mm(3); p = 0.176), and the number of calcified lesions was not significantly different (p = 0.092). One patient was reclassified to another risk category. The research protocol could be performed at a lower kV and resulted in a substantially lower radiation exposure, with a median volumetric CT dose index of 4.1 vs 5.2 mGy, respectively (p < 0.001). Our results showed that a consistent coronary calcium scoring can be achieved using a kV-independent protocol that lowers radiation doses compared to the standard protocol

    A highly-detailed anatomical study of left atrial auricle as revealed by in-vivo computed tomography

    Get PDF
    The left atrial auricle (LAA) is the main source of intracardiac thrombi, which contribute significantly to the total number of stroke cases. It is also considered a major site of origin for atrial fibrillation in patients undergoing ablation procedures. The LAA is known to have a high degree of morphological variability, with shape and structure identified as important contributors to thrombus formation. A detailed understanding of LAA form, dimension, and function is crucial for radiologists, cardiologists, and cardiac surgeons.This review describes the normal anatomy of the LAA as visualized through multiple imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and echocardi-ography. Special emphasis is devoted to a discussion on how the morphological characteristics of the LAA are closely related to the likelihood of developing LAA thrombi, including insights into LAA embryology

    Predictive Value of Cardiac CTA, Cardiac MRI, and Transthoracic Echocardiography for Cardioembolic Stroke Recurrence

    Get PDF
    Background: Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. While TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. Objectives: To investigate sensitivity, specificity and predictive value of cardiac CT angigography (cCTA), cardiac MRI (CMR), and TTE for recurrence in patients with suspected cardioembolic stroke. Methods: We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMR (n=75) or cCTA (n=76) between January 2013 and May 2017. We evaluated for presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end-point was stroke recurrence. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for recurrent stroke were calculated; the diagnostic accuracy of CMR, cCTA, and TTE was compared between and within groups using area under the curves (AUCs). Results: Twelve and 14 recurrent strokes occurred in the cCTA and CMR groups, respectively. Sensitivity, specificity, PPV and NPV were: 33.3%, 93.7%, 50.0%, and 88.2% for cCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMR; 14.3%, 83.6%, 16.7%, 80.9% for TTE in the CMR group, and 8.3%, 93.7%, 20.0% and 84.5% for TTE in the cCTA group. Accuracy was not different (p&gt;0.05) between cCTA (0.63, 95% CI [0.49, 0.77]), CMR (0.53, [0.42, 0.63]), TTE in CMR group (0.51, [0.40, 0.61], and TTE in cCTA group (0.51, [0.42, 0.59]). In cCTA group, atrial and ventricular thrombus were detected by cCTA in 3 patients and TTE in 1 patient; in CMR group, thrombus was detected by CMR in 1 patient and TTE in 2 patients. Conclusion: cCTA, CMR, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. cCTA and CMR may be valid alternatives to TTE. cCTA may be preferred given potentially better detection of atrial and ventricular thrombus. Clinical impact: cCTA and CMR have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings

    Registry of Aortic Diseases to Model Adverse Events and Progression (ROADMAP) in Uncomplicated Type B Aortic Dissection: Study Design and Rationale

    Full text link
    PURPOSE To describe the design and methodological approach of a multicenter, retrospective study to externally validate a clinical and imaging-based model for predicting the risk of late adverse events in patients with initially uncomplicated type B aortic dissection (uTBAD). MATERIALS AND METHODS The Registry of Aortic Diseases to Model Adverse Events and Progression (ROADMAP) is a collaboration between 10 academic aortic centers in North America and Europe. Two centers have previously developed and internally validated a recently developed risk prediction model. Clinical and imaging data from eight ROADMAP centers will be used for external validation. Patients with uTBAD who survived the initial hospitalization between January 1, 2001, and December 31, 2013, with follow-up until 2020, will be retrospectively identified. Clinical and imaging data from the index hospitalization and all follow-up encounters will be collected at each center and transferred to the coordinating center for analysis. Baseline and follow-up CT scans will be evaluated by cardiovascular imaging experts using a standardized technique. RESULTS The primary end point is the occurrence of late adverse events, defined as aneurysm formation (≥6 cm), rapid expansion of the aorta (≥1 cm/y), fatal or nonfatal aortic rupture, new refractory pain, uncontrollable hypertension, and organ or limb malperfusion. The previously derived multivariable model will be externally validated by using Cox proportional hazards regression modeling. CONCLUSION This study will show whether a recent clinical and imaging-based risk prediction model for patients with uTBAD can be generalized to a larger population, which is an important step toward individualized risk stratification and therapy.Keywords: CT Angiography, Vascular, Aorta, Dissection, Outcomes Analysis, Aortic Dissection, MRI, TEVAR© RSNA, 2022See also the commentary by Rajiah in this issue

    The dynamic range of the upgraded surface-detector stations of AugerPrime

    Get PDF
    The detection of ultra-high-energy cosmic rays by means of giant detector arrays is often limited by the saturation of the recorded signals near the impact point of the shower core at the ground, where the particle density dramatically increases. The saturation affects in particular the highest energy events, worsening the systematic uncertainties in the reconstruction of the shower characteristics. The upgrade of the Pierre Auger Observatory, called AugerPrime, includes the installation of an 1-inch Small PhotoMultiplier Tube (SPMT) inside each water-Cherenkov station (WCD) of the surface detector array. The SPMT allows an unambiguous measurement of signals down to about 250m from the shower core, thus reducing the number of events featuring a saturated station to a negligible level. In addition, a 3.8m2 plastic scintillator (Scintillator Surface Detector, SSD) is installed on top of each WCD. The SSD is designed to match the WCD (with SPMT) dynamic range, providing a complementary measurement of the shower components up to the highest energies. In this work, the design and performances of the upgraded AugerPrime surface-detector stations in the extended dynamic range are described, highlighting the accuracy of the measurements. A first analysis employing the unsaturated signals in the event reconstruction is also presented

    First results from the AugerPrime Radio Detector

    Get PDF

    Update of the Offline Framework for AugerPrime

    Get PDF

    Combined fit to the spectrum and composition data measured by the Pierre Auger Observatory including magnetic horizon effects

    Get PDF
    The measurements by the Pierre Auger Observatory of the energy spectrum and mass composition of cosmic rays can be interpreted assuming the presence of two extragalactic source populations, one dominating the flux at energies above a few EeV and the other below. To fit the data ignoring magnetic field effects, the high-energy population needs to accelerate a mixture of nuclei with very hard spectra, at odds with the approximate E2^{-2} shape expected from diffusive shock acceleration. The presence of turbulent extragalactic magnetic fields in the region between the closest sources and the Earth can significantly modify the observed CR spectrum with respect to that emitted by the sources, reducing the flux of low-rigidity particles that reach the Earth. We here take into account this magnetic horizon effect in the combined fit of the spectrum and shower depth distributions, exploring the possibility that a spectrum for the high-energy population sources with a shape closer to E2^{-2} be able to explain the observations
    corecore