7 research outputs found

    Case Report of Argininemia: The Utility of the Arginine/Ornithine Ratio for Newborn Screening (NBS)

    Get PDF
    We describe a case of Argininemia detected by Michigan Newborn Screening (NBS). The Secretary’s Advisory Committee on Heritable Disorders in Newborns and Children recommends that every MS/MS newborn screening program include Argininemia as part of their uniform screening panel. While affected infants will be detected by this testing, Arginine levels may take time to accumulate. Thus, some infants may not be detected by this methodology and early sample collection. In Michigan, since initiating testing for Argininemia in 2006, there has been workup of 23 cases for elevated Arginine identified by NBS, with one case identified as affected. We report this affected case. Subsequently, the Arginine/Ornithine ratio was calculated for all cases and was found to be informative with respect to predicting whether a patient is affected by Argininemia

    Improved Identification of Partial Biotinidase Deficiency by Newborn Screening Using Age-Related Enzyme Activity Cutoffs: Reduction of the False-Positive Rate

    No full text
    Background: Biotinidase deficiency is an inherited metabolic disorder that if untreated can result in neurological and cutaneous features. Profound biotinidase deficiency presents in early childhood with severe symptoms, whereas partial biotinidase deficiency can also present with symptoms under times of stress. Symptoms can be prevented by administering biotin. Newborn screening for the disorder is performed using dried blood spots. We examined the relationship between biotinidase activity and age at collection to determine how best to identify infants with partial biotinidase deficiency. Methods: Biotinidase activity in dried blood spots is determined using a quantitative fluorometric assay. Subsequent specimens with biotinidase activity ≀100 U were analyzed by mutation analysis to determine the range of activities expressed in infants with partial biotinidase deficiency. Results: Enzyme activity increased with age, beginning at about three days of age, and rose until plateauing at about 11 days of age. An increase of about 47.6% was observed. A total of 54 specimens had mutation analysis performed identifying 20 affected infants who would not have been identified using the original cutoff activity of 50 U. Conclusion: Biotinidase activity in infants increases with age. Age-related cutoffs assist in selectively identifying infants with partial biotinidase deficiency

    Newborn screening for dihydrolipoamide dehydrogenase deficiency: Citrulline as a useful analyte

    No full text
    Dihydrolipoamide dehydrogenase deficiency, also known as maple syrup urine disease (MSUD) type III, is caused by the deficiency of the E3 subunit of branched chain alpha-ketoacid dehydrogenase (BCKDH), α-ketoglutarate dehydrogenase (αKGDH), and pyruvate dehydrogenase (PDH). DLD deficiency variably presents with either a severe neonatal encephalopathic phenotype or a primarily hepatic phenotype. As a variant form of MSUD, it is considered a core condition recommended for newborn screening. The detection of variant MSUD forms has proven difficult in the past with no asymptomatic DLD deficiency patients identified by current newborn screening strategies. Citrulline has recently been identified as an elevated dried blood spot (DBS) metabolite in symptomatic patients affected with DLD deficiency. Here we report the retrospective DBS analysis and second-tier allo-isoleucine testing of 2 DLD deficiency patients. We show that an elevated citrulline and an elevated allo-isoleucine on second-tier testing can be used to successfully detect DLD deficiency. We additionally recommend that DLD deficiency be included in the “citrullinemia/elevated citrulline” ACMG Act Sheet and Algorithm

    Harmonizing Newborn Screening Laboratory Proficiency Test Results Using the CDC NSQAP Reference Materials

    No full text
    Newborn screening (NBS) laboratories cannot accurately compare mass spectrometry-derived results and cutoff values due to differences in testing methodologies. The objective of this study was to assess harmonization of laboratory proficiency test (PT) results using quality control (QC) data. Newborn Screening Quality Assurance Program (NSQAP) QC and PT data reported from 302 laboratories in 2019 were used to compare results among laboratories. QC materials were provided as dried blood spot cards which included a base pool and the base pool enriched with specific concentrations of metabolites in a linear range. QC data reported by laboratories were regressed on QC data reported by the Centers for Disease Control and Prevention (CDC), and laboratory’s regression parameters were used to harmonize their PT result. In general, harmonization tended to reduce overall variation in PT data across laboratories. The metabolites glutarylcarnitine (C5DC), tyrosine, and phenylalanine were displayed to highlight inter- and intra-method variability in NBS results. Several limitations were identified using retrospective data for harmonization, and future studies will address these limitations to further assess feasibility of using NSQAP QC data to harmonize PT data. Harmonizing NBS data using common QC materials appears promising to aid result comparison between laboratories

    Heptadecanoylcarnitine (C17) a novel candidate biomarker for newborn screening of propionic and methylmalonic acidemias

    No full text
    BACKGROUND: 3-Hydroxypalmitoleoyl-carnitine (C16:1-OH) has recently been reported to be elevated in acylcarnitine profiles of patients with propionic acidemia (PA) or methylmalonic acidemia (MMA) during expanded newborn screening (NBS). High levels of C16:1-OH, combined with other hydroxylated long chain acylcarnitines are related to long-chain 3-hydroxyacyl-CoA dehydrogenase deficiency (LCHADD) and trifunctional protein (TFP) deficiency. METHODS: The acylcarnitine profile of two LCHADD patients was evaluated using liquid chromatography-tandem mass spectrometric method. A specific retention time was determined for each hydroxylated long chain acylcarnitine. The same method was applied to some neonatal dried blood spots (DBSs) from PA and MMA patients presenting abnormal C16:1-OH concentrations. RESULTS: The retention time of the peak corresponding to C16:1-OH in LCHADD patients differed from those in MMA and PA patients. Heptadecanoylcarnitine (C17) has been identified as the novel biomarker specific for PA and MMA patients through high resolution mass spectrometry (Orbitrap) experiments. We found that 21 out of 23 neonates (22 MMA, and 1PA) diagnosed through the Tuscany region NBS program exhibited significantly higher levels of C17 compared to controls. Twenty-three maternal deficiency (21 vitamin B12 deficiency, 1 homocystinuria and 1 gastrin deficiency) samples and 82 false positive for elevated propionylcarnitine (C3) were also analyzed. CONCLUSIONS: We have characterized a novel biomarker able to detect propionate disorders during expanded newborn screening (NBS). The use of this new biomarker may improve the analytical performances of NBS programs especially in laboratories where second tier tests are not performed

    Enhanced interpretation of newborn screening results without analyte cutoff values

    No full text
    A collaboration among 157 newborn screening programs in 47 countries has lead to the creation of a database of 705,333 discrete analyte concentrations from 11,462 cases affected with 57 metabolic disorders, and from 631 heterozygotes for 12 conditions. This evidence was first applied to establish disease ranges for amino acids and acylcarnitines, and clinically validate 114 cutoff target ranges. Objective: To improve quality and performance with an evidence-based approach, multivariate pattern recognition software has been developed to aid in the interpretation of complex analyte profiles. The software generates tools that convert multiple clinically significant results into a single numerical score based on overlap between normal and disease ranges, penetration within the disease range, differences between specific conditions, and weighted correction factors. Design: Eighty-five on-line tools target either a single condition or the differential diagnosis between two or more conditions. Scores are expressed as a numerical value and as the percentile rank among all cases with the condition chosen as primary target, and are compared to interpretation guidelines. Tools are updated automatically after any new data submission (2009- 2011: 5.2 new cases added per day on average). Main outcome measures: Retrospective evaluation of past cases suggest that these tools could have avoided at least half of 277 false positive outcomes caused by carrier status for fatty acid oxidation disorders, and could have prevented 88% of false negative events caused by cutoff 7 values set inappropriately. In Minnesota, their prospective application has been a major contributing factor to the sustained achievement of a false positive rate below 0.1% and a positive predictive value above 60%. Conclusions: Application of this computational approach to raw data could make cutoff values for single analytes effectively obsolete. This paradigm is not limited to newborn screening and is applicable to the interpretation of diverse multi-analyte profiles utilized in laboratory medicine. Abstract wor

    Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: A worldwide collaborative project

    Get PDF
    PURPOSE:: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. METHODS:: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742 deidentified true positive cases are compared to assign clinical significance, which is achieved when the median of a disorder range is, and usually markedly outside, either the 99th or the 1st percentile of the normal population. The cutoff target ranges of analytes and ratios are then defined as the interval between selected percentiles of the two populations. When overlaps occur, adjustments are made to maximize sensitivity and specificity taking all available factors into consideration. RESULTS:: As of December 1, 2010, 130 sites in 45 countries have uploaded a total of 25,114 percentile data points, 565,232 analyte results of true positive cases with 64 conditions, and 5,341 cutoff values. The average rate of submission of true positive cases between December 1, 2008, and December 1, 2010, was 5.1 cases/day. This cumulative evidence generated 91 high and 23 low cutoff target ranges. The overall proportion of cutoff values within the respective target range was 42% (2,269/5,341). CONCLUSION:: An unprecedented level of cooperation and collaboration has allowed the objective definition of cutoff target ranges for 114 markers to be applied to newborn screening of rare metabolic disorders. © 2011 Lippincott Williams & Wilkins
    corecore