12 research outputs found
Science Objectives for an X-Ray Microcalorimeter Observing the Sun
We present the science case for a broadband X-ray imager with high-resolution spectroscopy, including simulations of X-ray spectral diagnostics of both active regions and solar flares. This is part of a trilogy of white papers discussing science, instrument (Bandler et al. 2010), and missions (Bookbinder et al. 2010) to exploit major advances recently made in transition-edge sensor (TES) detector technology that enable resolution better than 2 eV in an array that can handle high count rates. Combined with a modest X-ray mirror, this instrument would combine arcsecondscale imaging with high-resolution spectra over a field of view sufficiently large for the study of active regions and flares, enabling a wide range of studies such as the detection of microheating in active regions, ion-resolved velocity flows, and the presence of non-thermal electrons in hot plasmas. It would also enable more direct comparisons between solar and stellar soft X-ray spectra, a waveband in which (unusually) we currently have much better stellar data than we do of the Sun
Science with Micro-X: the TES Microcalorimeter X-ray Imaging Rocket
Micro-X is a proposed sounding rocket experiment that will combine a transition-edge-sensor X-ray-microcalorimeter array with a conical imaging mirror to obtain high-spectral-resolution images of extended and point X-ray sources. We describe the payload and the science targeted by this mission including the discussion of three possible Micro-X targets: the Puppis A supernova remnant, the Virgo Cluster, and Circinus X-1. For example, a Micro-X observation of the bright eastern knot of Puppis A will obtain a line-dominated spectrum with 90,000 counts collected in 300 seconds at 2 eV resolution across the 0.3-2.5 keV band. Micro-X will utilize plasma diagnostics to determine the thermodynamic and ionization state of the plasma, to search for line shifts and broadening associated with dynamical processes, and seek evidence of ejecta enhancement. For clusters of galaxies, Micro-X can uniquely study turbulence and the temperature distribution function. For binaries, Micro-X's high resolution spectra will separate the different processes contributing to the Fe K lines at 6 keV and give a clear view of the geometry of the gas flows and circumstellar gas
Distributed Transition Edge Sensors for Linearized Position Response in a Phonon-Mediated X-ray Imaging Spectrometer
For future solar X-ray satellite missions, we are developing a phonon-mediated macro-pixel composed of a Ge crystal absorber with four superconducting transition-edge sensors (TES) distributed on the backside. The X-rays are absorbed on the opposite side and the energy is converted into phonons, which are absorbed into the four TES sensors. By connecting together parallel elements into four channels, fractional total energy absorbed between two of the sensors provides x-position information and the other two provide y-position information. We determine the optimal distribution for the TES sub-elements to obtain linear position information while minimizing the degradation of energy resolution
Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays
LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable
Recommended from our members
Development of the manufacturing and QA processes for the magnetic modules of the LCLS-II soft X-ray undulators
A new free electron laser being built at SLAC National Accelerator Laboratory, the Linear Coherent Light Source II (LCLS-II), will use 21 soft x-ray undulators (SXR) and 32 hard x-ray undulators (HGVPU). Lawrence Berkeley National Laboratory (LBNL) is responsible for the design and manufacturing of all variable-gap, hybrid permanent-magnet undulators. The physics requirements for the undulators specify a longitudinal pole misalignment maximum rms error of 25 µm and a vertical pole misalignment maximum error of 50 µm. In addition, magnet positioning critically influences the gap-dependent field properties due to saturation effects at the smallest operational gaps. This paper discusses the manufacturing and QA methods developed to carefully control the longitudinal and vertical pole and magnet positions during undulator production. Inspection results are discussed based on data gathered during construction of a prototype as well as pre-production soft x-ray undulator
Recommended from our members
Micro-X: Mission Overview and Science Goals
Micro-X, the High-Resolution Microcalorimeter X-ray Imaging Rocket, is a sounding rocket space telescope that will combine a transition-edge-sensor (TES) X-ray microcalorimeter array with a conical imaging mirror to obtain high spectral resolution images of extended and point X-ray sources. Microcalorimeters measure the energy of an absorbed photon by sensing the increase in temperature of the sensor from the thermalization of the absorbed photon’s energy. The advantages and scientific promise of this technology have fueled active development for the past 20 years. We will leverage this development and take the next step by producing a flight-qualified system that will serve as a pathfinder for future missions. Our scientific program will initially focus on extended sources, for which our high-spectral-resolution observations have distinct advantages over other technologies. For our initial flight, we will observe the bright eastern knot in the Puppis A remnant, a site of complex cloud-shock interactions and ejecta enrichment. A Micro-X observation of the bright eastern knot of Puppis A will obtain a line-dominated spectrum with 90,000 counts collected in 300 seconds at 2 eV resolution across the 0.3–2.5 keV band
Recommended from our members
Progress on the Micro-X rocket payload
The Micro-X High Resolution Microcalorimeter X-ray Imaging Rocket is sounding rocket experiment that will combine a transition-edge-sensor X-ray-microcalorimeter array with a conical imaging mirror to obtain high-spectral-resolution images of extended and point X-ray sources. Our first target is the Puppis A supernova remnant, which will be observed in January 2011. The Micro-X observation of the bright eastern knot of Puppis A will obtain a line-dominated spectrum with up to 90,000 counts collected in 300 seconds at 2 eV resolution across the 0.3-2.5 keV band. Micro-X will utilize plasma diagnostics to determine the thermodynamic and ionization state of the plasma, to search for line shifts and broadening associated with dynamical processes, and seek evidence of ejecta enhancement. We describe the progress made in developing this payload, including the detector, cryogenics, and electronics assemblies. A detailed modeling effort has been undertaken to design a rocket-bourne adiabatic demagnetization refrigerator with sufficient magnetic shielding to allow stable operation of transition edge sensors, and the associated rocket electronics have been prototyped and tested