22 research outputs found

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    New approach to direct stenting using a novel "all-in-one" coronary stent system via 5 French diagnostic catheters: a pilot study

    No full text
    OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US 600percase(US600 per case (US 212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings

    Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators.

    Full text link
    The purpose of this study was to determine the feasibility, safety, and efficacy of elective stenting with heparin-coated Wiktor stents in patients with coronary artery disease. In experimental studies, heparin coating has been shown to prevent subacute thrombosis and restenosis. Recently, a new method of heparin coating was developed, resulting in a more stable and predictable heparin layer on stent devices. This trial constitutes the first in-human use of this coating procedure, applied on the well-known Wiktor stent device. Heparin-coated Wiktor stent implantation was performed in 132 consecutive patients (132 lesions) in a multicenter international trial from September 1996 to February 1997. Forty-three percent of patients had unstable angina, 33% had previous myocardial infarction, and 10% had diabetes mellitus. Patients were followed for 12 months for occurrence of major adverse cardiovascular events, and 96% of the eligible patients underwent quantitative angiographic control at 6 months. Stent deployment was successful in 95.5% of lesions. Minimal lumen diameter increased by 1.67 +/- 0.48 mm (from 1.02 +/- 0.38 mm before to 2.69 +/- 0.37 mm after the stent implantation). Mean percent diameter stenosis decreased from 67.4 +/- 11.3% before to 18.9 +/- 7.7% after the intervention. A successful intervention (<50% diameter stenosis and no major adverse cardiac events within 30 days) occurred in 97% of the patients. The subacute thrombosis rate was 0.8%, which compares favorably with historical controls of this stent, and a low incidence of postprocedural increase in creatine kinase-MB was noted. At 6 months, event-free survival was 85% and angiographic restenosis rate was 22% with late loss of 0.78 +/- 0.69 mm and a loss index of 0.48 +/- 0.44. Heparin-coated Wiktor stents appeared to be an efficacious device to treat Benestent-like lesions, yielding angiographic and clinical results comparable to a heparin-coated Palmaz-Schatz stent. Despite its use in more complex lesions, the incidence of subacute thrombosis appeared to be lower than historical controls with a similar noncoated stent
    corecore