392 research outputs found

    Subtraction electrocardiography: Detection of ischemia-induced ST displacement without the need to identify the J point

    Get PDF
    AbstractBackgroundWhen triaging a patient with acute chest pain at first medical contact, an electrocardiogram (ECG) is routinely made and inspected for signs of myocardial ischemia. The guidelines recommend comparison of the acute and an earlier-made ECG, when available. No concrete recommendations for this comparison exist, neither is known how to handle J-point identification difficulties. Here we present a J-point independent method for such a comparison.MethodsAfter conversion to vectorcardiograms, baseline and acute ischemic ECGs after 3minutes of balloon occlusion during elective PCI were compared in 81 patients of the STAFF III ECG database. Baseline vectorcardiograms were subtracted from ischemic vectorcardiograms using either the QRS onsets or the J points as synchronization instants, yielding vector magnitude difference signals, ΔH. Output variables for the J-point synchronized differences were ΔH at the actual J point and at 20, 40, 60 and 80ms thereafter. Output variables for the onset-QRS synchronized differences were the ΔH at 80, 100, 120, 140 and 160ms after onset QRS. Finally, linear regressions of all combinations of ΔHJ+… versus ΔHQRS+… were made, and the best combination was identified.ResultsThe highest correlation, 0.93 (p<0.01), was found between ΔH 40ms after the J point and 160ms after the onset of the QRS complex. With a ΔH ischemia threshold of 0.05mV, 66/81 (J-point synchronized differences) and 68/81 (onset-QRS synchronized differences) subjects were above the ischemia threshold, corresponding to sensitivities of 81% and 84%, respectively.ConclusionOur current study opens an alternative way to detect cardiac ischemia without the need for human expertise for determination of the J point by measuring the difference vector magnitude at 160ms after the onset of the QRS complex

    Inappropriate Implantable Cardioverter-Defibrillator Shocks Incidence, Predictors, and Impact on Mortality

    Get PDF
    ObjectivesThe purpose of this study was to assess the incidence, predictors, and outcome of inappropriate shocks in implantable cardioverter-defibrillator (ICD) patients.BackgroundDespite the benefits of ICD therapy, inappropriate defibrillator shocks continue to be a significant drawback. The prognostic importance of inappropriate shocks outside the setting of a clinical trial remains unclear.MethodsFrom 1996 to 2006, all recipients of defibrillator devices equipped with intracardiac electrogram storage were included in the current analysis and clinically assessed at implantation. During follow-up, the occurrence of inappropriate ICD shocks and all-cause mortality was noted.ResultsA total of 1,544 ICD patients (79% male, age 61 ± 13 years) were included in the analysis. During the follow-up period of 41 ± 18 months, 13% experienced ≥1 inappropriate shocks. The cumulative incidence steadily increased to 18% at 5-year follow-up. Independent predictors of the occurrence of inappropriate shocks included a history of atrial fibrillation (hazard ratio [HR]: 2.0, p < 0.01) and age younger than 70 years (HR: 1.8, p = 0.01). Experiencing a single inappropriate shock resulted in an increased risk of all-cause mortality (HR: 1.6, p = 0.01). Mortality risk increased with every subsequent shock, up to an HR of 3.7 after 5 inappropriate shocks.ConclusionsIn a large cohort of ICD patients, inappropriate shocks were common. The most important finding is the association between inappropriate shocks and mortality, independent of interim appropriate shocks

    Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients

    Get PDF
    ObjectivesThis study aimed to assess the prevalence of different types of atrial fibrillation (AF) and their prognostic importance in implantable cardioverter-defibrillator (ICD) patients.BackgroundThe prevalence of AF has taken epidemic proportions in the population with cardiovascular disease. The prognostic importance of different types of AF in ICD patients remains unclear.MethodsData on 913 consecutive patients (79% men, mean age 62 ± 13 years) receiving an ICD at the Leiden University Medical Center were prospectively collected. Among other characteristics, the existence and type of AF (paroxysmal, persistent, or permanent) were assessed at implantation. During follow-up, the occurrence of appropriate or inappropriate device therapy as well as mortality was noted.ResultsAt implantation, 73% of patients had no history of AF, 9% had a history of paroxysmal AF, 7% had a history of persistent AF, and 11% had permanent AF. During 833 ± 394 days of follow-up, 117 (13%) patients died, 228 (25%) patients experienced appropriate device discharge, and 139 (15%) patients received inappropriate shocks. Patients with permanent AF exhibited more than double the risk of mortality, ventricular arrhythmias triggering device discharge, and inappropriate device therapy. Patients with paroxysmal or persistent AF did not show a significant increased risk of mortality or appropriate device therapy but demonstrated almost 3 times the risk of inappropriate device therapy.ConclusionsIn the population currently receiving ICD treatment outside the setting of clinical trials, a large portion has either a history of AF or permanent AF. Both types of AF have prognostic implications for mortality and appropriate as well as inappropriate device discharge

    Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex

    Get PDF
    Aims Current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30% of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with echocardiography. To further elucidate the possible beneficial effect of CRT in heart failure patients with a narrow QRS complex, this two-centre, non-randomized observational study focused on different echocardiographic parameters of LV mechanical dyssynchrony reflecting atrioventricular, interventricular and intraventricular dyssynchrony, and the response to CRT in these patients. Methods and results A total of 123 consecutive heart failure patients with a narrow QRS complex (<120 ms) undergoing CRT was included at two centres. Several widely accepted measures of mechanical dyssynchrony were evaluated: LV filling ratio (LVFT/RR), LV pre-ejection time (LPEI), interventricular mechanical dyssynchrony (IVMD), opposing wall delay (OWD), and anteroseptal posterior wall delay with speckle tracking (ASPWD). Response to CRT was defined as a reduction ≥15% in left ventricular end-systolic volume at 6 months follow-up. Measures of dyssynchrony can frequently be observed in patients with a narrow QRS complex. Nonetheless, for LVFT/RR, LPEI, and IVMD, presence of predefined significant dyssynchrony is <20%. Significant intraventricular dyssynchrony is more widely observed in these patients. With receiver operator characteristic curve analyses, both OWD and ASPWD demonstrated usefulness in predicting response to CRT in narrow QRS patients with a cut-off value of 75 and 107 ms, respectively. Conclusion Mechanical dyssynchrony can be widely observed in heart failure patients with a narrow QRS complex. In particular, intraventricular measures of mechanical dyssynchrony may be useful in predicting LV reverse remodelling at 6 months follow-up in heart failure patients with a narrow QRS complex, but with more stringent cut-off values than currently used in ‘wide' QRS patient

    Left Ventricular Diastolic Dysfunction in Dialysis Patients Assessed by Novel Speckle Tracking Strain Rate Analysis: Prevalence and Determinants

    Get PDF
    Background. Diastolic dysfunction is common among dialysis patients and is associated with increased morbidity and mortality. Novel echocardiographic speckle tracking strain analysis permits accurate assessment of left ventricular diastolic function, independent of loading conditions and taking all myocardial segments into account. The aim of the study was to evaluate the prevalence of diastolic dysfunction in chronic dialysis patients using this novel technique, and to identify its determinants among clinical and echocardiographic variables. Methods. Patients currently enrolled in the ICD2 study protocol were included for this analysis. Next to conventional echo measurements diastolic function was also assessed by global diastolic strain rate during isovolumic relaxation (SRIVR). Results. A total of 77 patients were included (age 67 ± 8 years, 74% male). When defined as E/SRIVR ≥236, the prevalence of diastolic dysfunction was higher compared to more conventional measurements (48% versus 39%). Left ventricular mass (OR 1.02, 95% CI 1.00–1.04, P = 0.014) and pulse wave velocity (OR 1.34, 95% CI 1.07–1.68, P = 0.01) were independent determinants of diastolic dysfunction. Conclusion. Diastolic dysfunction is highly prevalent among dialysis patients and might be underestimated using conventional measurements. Left ventricular mass and pulse wave velocity were the only determinants of diastolic dysfunction in these patients

    Non-Invasive Visualization of the Cardiac Venous System in Coronary Artery Disease Patients Using 64-Slice Computed Tomography

    Get PDF
    ObjectivesThis study was designed to evaluate the value of 64-slice computed tomography (CT) to visualize the cardiac veins and evaluate the relation between variations in venous anatomy and history of infarction.BackgroundCardiac resynchronization therapy (CRT) is an attractive treatment for selected heart failure patients. Knowledge of venous anatomy may help in identifying candidates for successful left ventricular lead implantation.MethodsThe 64-slice CT of 100 individuals (age 61 ± 11 years, 68% men) was studied. Subjects were divided into 3 groups: 28 control patients, 38 patients with significant coronary artery disease (CAD), and 34 patients with a history of infarction. Presence of the following coronary sinus (CS) tributaries was evaluated: posterior interventricular vein (PIV), posterior vein of the left ventricle, and left marginal vein (LMV). Vessel diameters were also measured.ResultsCoronary sinus and PIV were identified in all individuals. Posterior vein of the left ventricle was observed in 96% of control patients, 84% of CAD patients, and 82% of infarction patients. In patients with a history of infarction, a LMV was significantly less observed as compared with control patients and CAD patients (27% vs. 71% and 61%, respectively, p < 0.001). None of the patients with lateral infarction and only 22% of patients with anterior infarction had a LMV. Regarding quantitative data, no significant differences were observed between the groups.ConclusionsNon-invasive evaluation of cardiac veins with 64-slice CT is feasible. There is considerable variation in venous anatomy. Patients with a history of infarction were less likely to have a LMV, which may hamper optimal left ventricular lead positioning in CRT implantation