16 research outputs found

    Degradation of solvent mixture vapors in a biotrickling filter reactor: impact of hydrophilic components loading and loading release dynamic

    Get PDF
    [Abstract] Interactions amongst the degradation rates of toluene, xylenes, methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), n-butyl acetate (n-BA), and acetone (Ac) were investigated in a biotrickling filter reactor. The reactor was packed with polypropylene High-Flow rings in a counter-current airwater mode of operation. Performance evaluation of the reactor with increased hydrophilic compound loading while maintaining a steady loading rate of hydrophobic components, were evaluated. The dynamic responses of the individual solvent components following a drop of the ketone loading rate are also described in a second phase of experiments. The degradation rate of aromatics became partially inhibited at OLKET of 15 g.m-3.h-1; below this level all of the ketones were totally degraded. Once the organic loading exceeded a value of 40 g.m-3.h-1 the removal efficiency of all the components (except n-BA) began to drop sharply. At OLKET of 85 g.m-3.h-1 the RE of aromatics dropped to below 10 %, that of acetone to 10 %, MEK and MIBK to 20 %, but n-BA removal remained above 97 %. A step-decrease of the OLKET from 85 to 5 g.m-3.h-1 resulted in a rapid increase of REAROM to 30 % (in 20 min). After the decrease, the level of REKET quickly reached 90 %, specifically: for MEK this occurred in about 4 min, for MIBK in about 25 min but for acetone, this was not achieved until after a period of 3.5 h. The significantly longer time period of REAc to achieve the original value was a consequence of: (1) its slower degradation rate resulting from a degradation competition with the other components, (2) the inhibitory effect resulting from acetone unlimited water solubility, and (3) a high quantity of acetone being accumulated in a circulating aqueous medium

    Paint solvent components degradation from their mixture along the biotrickling bed height

    Get PDF
    Czech Science Foundation; 104/05/0194Czech Republic. Ministry of Education, Youth and Sports; MSM 6046137305

    Styrene degradation in perlite biofilter: the overall performance characteristics and dynamic response

    Get PDF
    [Abstract] Styrene’s degradation in a perlite biofilter including the long-term operation, dynamic response to step-changes in inlet concentration and non-use periods were tested. The study was performed in a bench-scale biofilter with ID 100 mm and a bed height of 1 m. Perlite with a particle size of 2 – 4 mm was used as a packing material. An enrichment mixed culture was immobilized on the packing. The inoculum was obtained from a styrene biofilter. Two different loading conditions were tested: (1) Loading with a high inlet concentration and a high residence time. (2) Loading with a low inlet concentration and the low residence time. Both conditions are common in industrial practice. The dynamic response to a repeated step-change in the inlet concentration (from 50 to 200 mg.m-3) was tested. The dynamic behaviour of the restarting period after varying periods of non-use was also investigated. The results demonstrate a high biofilter stability under extreme loading conditions and also during the step-changes of the inlet concentration. The non-use periods tested had almost no effect on the biofilter performance. The maximum outlet concentration after the restarting of the load was 4 mg.m-3, when a 95 hours idle period was used. After shorter idle periods, the outlet styrene concentrations did not exceed 0.6 mg.m-3

    Gasoline biofiltration: an analytic model

    Get PDF
    [Abstract] We present an analytical method of solution for a pair of models representing the removal of gasoline from air by biofiltration. The experimental data showed that the aromatic components of the gasoline were more readily digested than the aliphatics. The models, involving two or three fitted parameters, fitted the laboratory data well

    Steady-State Performance of an Activated Carbon Biofilter Degrading Styrene: Effects of Residence Time and Inlet Concentration

    No full text
    A granular-activated-carbon-packed biofilter receiving a constant loading rate of styrene was subjected to changes in residence time and concentration, and the effects on performance characteristics and the composition of biofilm along the bed height in the biofilter were studied. This study was carried out during the last 3 months of the entire biofilter operation of 16 months. The total bed height of the biofilter was physically divided into four individual reactor stages in series. This configuration permitted measurement of the leachate pH in each stage. Also, between-stage mixing of the culture was minimized. Each reactor stage was loaded in an upflow mode. The shortest residence time tested, 1.05 min, resulted in a decrease of removal efficiency to 95% (from 100% achieved at longer residence times). The shorter residence time nonetheless resulted in a higher elimination capacity in the higher stages of the filter bed. In the first two stages, the leachate pH values were 6.4 and 6.6, slightly lower than in higher stages (pH 7). A decrease of the styrene concentration along the bed height significantly affected the total cell number of immobilized cells whereas the number of degraders, Pseudomonads, and eukaryotes changed only a little. Microbial analysis of the mixed culture showed the presence of four bacterial strains and three fungi

    Laboratory scale cultivation of Salinispora tropica in shake flasks and mechanically stirred bioreactors

    No full text
    Objective: Marine actinomycetes from the genus Salinispora have an unexploited biotechnological potential. To accurately estimate their application potential however, data on their cultivation, including biomass growth kinetics, are needed but only incomplete information is currently available. Results: This work provides some insight into the effect of temperature, salinity, nitrogen source, glucose concentration and oxygen supply on growth rate, biomass productivity and yield of Salinispora tropica CBN-440T. The experiments were carried out in unbaffled shake flasks and agitated laboratory-scale bioreactors. The results show that the optimum growth temperature lies within the range 28-30 \ub0C, salinity is close to sea water and the initial glucose concentration is around 10 g/L. Among tested nitrogen sources, yeast extract and soy peptone proved to be the most suitable. The change from unbaffled to baffled flasks increased the volumetric oxygen transfer coefficient (kLa) as did the use of agitated bioreactors. The highest specific growth rate (0.0986 h-1) and biomass productivity (1.11 g/L/day) were obtained at kLa = 28.3 h-1. A further increase in kLa was achieved by increasing stirrer speed, but this led to a deterioration in kinetic parameters. Conclusions: Improvement of S. tropica biomass growth kinetics of was achieved mainly by identifying the most suitable nitrogen sources and optimizing kLa in baffled flasks and agitated bioreactors

    Biofiltration of a styrene/acetone vapor mixture in two reactor types under conditions of styrene overloading

    No full text
    This aim of study was to compare the performance of a biofilter (BF) and trickle bed reactor (TBR) under increased styrene loading with a constant acetone load, 2 gc/m3/h. At styrene loading rates up to 30 gc/m3/h, the BF showed higher styrene removal than TBR. However, the BF efficiency started to drop beyond this threshold loading and could never reach steady state, whereas the TBR continued to yield a 50% styrene removal. The acetone removal remained constant (93-98%) in both the reactors at any styrene loading. Once the overloading was lifted, the BF recovered within 26 min, whereas the TBR efficiency bounced back only to 95%, gradually returning to complete removal only in 10 h
    corecore