2,031 research outputs found

    Against the Linguistic Analogy

    Get PDF
    Recently it has been proposed that humans possess an innate, domain-specific moral faculty, and that this faculty might be fruitfully understood by drawing a close analogy with nativist theories in linguistics. This Linguistic Analogy (LA) hypothesizes that humans share a universal moral grammar. In this paper I argue that this conception is deeply flawed. After profiling a recent and appealing account of universal moral grammar, I suggest that recent empirical findings reveal a significant flaw, which takes the form of a dilemma: either there is something wrong with the moral grammar model because we do not actually possess the innate contents (rules, principles, and concepts) it says we have, or the moral grammar model is simply the wrong model of moral cognition. In light of this dilemma, I conclude we ought to be skeptical that the Linguistic Analogy can adequately serve as a general account of moral cognition

    Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>To examine relationships between severity of echocardiography (echo) -evidenced diastolic dysfunction (DD) and volumetric filling by automated processing of routine cine cardiovascular magnetic resonance (CMR).</p> <p>Background</p> <p>Cine-CMR provides high-resolution assessment of left ventricular (LV) chamber volumes. Automated segmentation (LV-METRIC) yields LV filling curves by segmenting all short-axis images across all temporal phases. This study used cine-CMR to assess filling changes that occur with progressive DD.</p> <p>Methods</p> <p>115 post-MI patients underwent CMR and echo within 1 day. LV-METRIC yielded multiple diastolic indices - E:A ratio, peak filling rate (PFR), time to peak filling rate (TPFR), and diastolic volume recovery (DVR<sub>80 </sub>- proportion of diastole required to recover 80% stroke volume). Echo was the reference for DD.</p> <p>Results</p> <p>LV-METRIC successfully generated LV filling curves in all patients. CMR indices were reproducible (≤ 1% inter-reader differences) and required minimal processing time (175 ± 34 images/exam, 2:09 ± 0:51 minutes). CMR E:A ratio decreased with grade 1 and increased with grades 2-3 DD. Diastolic filling intervals, measured by DVR<sub>80 </sub>or TPFR, prolonged with grade 1 and shortened with grade 3 DD, paralleling echo deceleration time (p < 0.001). PFR by CMR increased with DD grade, similar to E/e' (p < 0.001). Prolonged DVR<sub>80 </sub>identified 71% of patients with echo-evidenced grade 1 but no patients with grade 3 DD, and stroke-volume adjusted PFR identified 67% with grade 3 but none with grade 1 DD (matched specificity = 83%). The combination of DVR<sub>80 </sub>and PFR identified 53% of patients with grade 2 DD. Prolonged DVR<sub>80 </sub>was associated with grade 1 (OR 2.79, CI 1.65-4.05, p = 0.001) with a similar trend for grade 2 (OR 1.35, CI 0.98-1.74, p = 0.06), whereas high PFR was associated with grade 3 (OR 1.14, CI 1.02-1.25, p = 0.02) DD.</p> <p>Conclusions</p> <p>Automated cine-CMR segmentation can discern LV filling changes that occur with increasing severity of echo-evidenced DD. Impaired relaxation is associated with prolonged filling intervals whereas restrictive filling is characterized by increased filling rates.</p

    CO, Water, and Tentative Methanol in η Carinae Approaching Periastron

    Get PDF
    The complex circumstellar environment around the massive binary and luminous blue variable η Carinae is known to harbor numerous light molecules, emitting most strongly in rotational states with upper level energies to ~300 K. In circumstellar gas, the complex organic molecule methanol (CH₃OH) has been found almost exclusively around young stellar objects, and thus regarded as a signpost of recent star formation. Here we report the first potential detection of methanol around a highly evolved high-mass star, while using the Atacama Large Millimeter Array to investigate molecular cloud conditions traced by CO (2–1) in an orbit phase preceding the 2020 periastron. The methanol emission originates from hot (T_(gas) ≃ 700 K) material, ~2'' (0.02 pc) across, centered on the dust-obscured binary, and is accompanied by prominent absorption of continuum radiation in a cooler (T_(gas) ≃ 110 K) layer of gas. We also report a first detection of water in Herschel observations at 557 and 988 GHz. The methanol abundance is several to 50 times higher than observed toward several lower-mass stars, while water abundances are similar to those observed in cool, dense molecular clouds. The very high methanol:water abundance ratio in the core of η Car may suggest methanol formation processes similar to Fischer–Tropsch-type catalytic reactions on dust grains. These observations prove that complex molecule formation can occur in a chemically evolved massive stellar environment, given sufficient gas densities and shielding conditions as may occur in material around massive interacting companions and merger remnants

    Improved Left Ventricular Mass Quantification with Partial Voxel Interpolation – In-Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm

    Get PDF
    Background—CMR typically quantifies LV mass (LVM) via manual planimetry (MP), but this approach is time consuming and does not account for partial voxel components - myocardium admixed with blood in a single voxel. Automated segmentation (AS) can account for partial voxels, but this has not been used for LVM quantification. This study used automated CMR segmentation to test the influence of partial voxels on quantification of LVM. Methods and Results—LVM was quantified by AS and MP in 126 consecutive patients and 10 laboratory animals undergoing CMR. AS yielded both partial voxel (ASPV) and full voxel (ASFV) measurements. Methods were independently compared to LVM quantified on echocardiography (echo) and an ex-vivo standard of LVM at necropsy. AS quantified LVM in all patients, yielding a 12-fold decrease in processing time vs. MP (0:21±0:04 vs. 4:18±1:02 min; pFV mass (136±35gm) was slightly lower than MP (139±35; Δ=3±9gm, pPV yielded higher LVM (159±38gm) than MP (Δ=20±10gm) and ASFV (Δ=23±6gm, both pPV and ASFV correlated with larger voxel size (partial r=0.37, pPV yielded better agreement with echo (Δ=20±25gm) than did ASFV (Δ=43±24gm) or MP (Δ=40±22gm, both pPV and ex-vivo results were similar (Δ=1±3gm, p=0.3), whereas ASFV (6±3g, P\u3c0.001) and MP (4±5 g, P=0.02) yielded small but significant differences with LVM at necropsy

    Present and Future CP Measurements

    Get PDF
    We review theoretical and experimental results on CP violation summarizing the discussions in the working group on CP violation at the UK phenomenology workshop 2000 in Durham.Comment: 104 pages, Latex, to appear in Journal of Physics

    Atrial Fibrillation Burden and Atrial Shunt Therapy in Heart Failure With Preserved Ejection Fraction

    Get PDF
    Background: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). Objectives: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. Methods: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. Results: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. Conclusions: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden.</p

    Search for gravitational wave bursts in LIGO's third science run

    Get PDF
    We report on a search for gravitational wave bursts in data from the three LIGO interferometric detectors during their third science run. The search targets subsecond bursts in the frequency range 100-1100 Hz for which no waveform model is assumed, and has a sensitivity in terms of the root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published in Classical and Quantum Gravit
    corecore