23 research outputs found

    Dynamic impedances of bridge abutments

    Get PDF
    The soil-structure interaction at bridge abutments may introduce important changes in the dynamic properties of short to medium span bridges. The paper presents the results obtained, through the use of the Boundary Element Method (B.E.M.) technique in several typical situations, including semiinfinite and layered media. Both stiffness and damping properties are included

    Simplified modelling of bridge abutments-soil interaction under seismic effects

    Get PDF
    A simplified model is proposed to show the importance that the dynamic soil-abutment interaction can have in the global behavior of bridges submitted to seismic loading. The modification of natural frequency and damping properties is shown in graphic form for typical short span bridges of the integral deck-abutment type for longitudinal vibrations or general ones for transverse vibrations

    Dynamic stiffness analysis of bridge abutments

    Get PDF
    Strong motion records obtained in instrumented short-span bridges show the importance of the abutments in the dynamic response of the structure. Existing models study the pier foundation influence but not the abutment performance. This work proposes two and three dimensional boundary element models in the frequency domain and studies the dimensionless dynamic stiffness of standard bridge abutments

    Instrumentación GPS de pruebas de carga en el Nuevo Puente de Ventas sobre la M-30 en Madrid

    Full text link
    Se muestra en este artículo el trabajo realizado durante las pruebas de carga de puesta en servicio del Nuevo Puente de Ventas sobre la M-30 de Madrid, con el fin de determinar los desplazamientos producidos mediante la aplicación de técnicas GPS, así como la discusión de precisiones obtenidas y posibilidades que encierra este tipo de sistemas de instrumentación de deformaciones en obra civil

    Dynamic Soil-Structure Interaction in Bridge Abutments

    Full text link
    Strong motion obtained in instrumental short-span bridges show the importance of the abutments in the dynamic response of the whole structure. Many models have been used in order to take into account the influence of pier foundations although no reliable ones have been used to analyse the abutment performance. In this work three-dimensional Boundary Element models in frequency domain have been proposed and dimensionless dynamic stiffness of standard bridge abutments have been obtained

    Abutments influence in the dynamic response of bridges

    Get PDF
    A simplified analytical model of a short span bridge is proposed. The inertial interaction effects of pier foundations and abutments has been included in order to evaluate the response sensitivities to different soil-structure interaction variables. The modification of natural frequency and damping properties is shown for typical short span bridges of the integral deck-abutment type for longitudinal vibrations or general bridges for the transverse ones

    Rigidez dinámica de estribos y puentes

    Full text link
    Los datos obtenidos de puentes instrumentados en zonas sísmicas, demuestran la importancia que tienen los estribos en la respuesta dinámica de la estructura. Si bien existen modelos que permiten estudiar la incidencia de las cimentaciones de las pilas, no existe ningún modelo analítico un numérico que permita acotar la incidencia d e los estribos. En este trabajo se presentan modelos de Elementos de Contorno en el dominio de la frecuencia, tanto en dos como en tres dimensiones, así como el cálculo de las rigideces dinámicas delos estribos, en forma adimensional, para las tipologías más habituales. Finalmente, en un modelo analítico sencillo de un tablero de puente en el que se incorporan los efectos de interacción inercial en la cimentación de pilas y estribos, se analizan las variables de la respuesta dinámica modificada

    Application of the Boundary Element Method to the Analysis of Bridge Abutments

    Full text link
    The B.E. technique is applied to an interesting dynamic problem: the interaction between bridges and their abutments. Several two-dimensional cases have been tested in relation with previously published analytical results. A three-dimensional case is also shown and different considerations in relation with the accuracy of the method are described

    Improved Integration Methods for P-Adaptive Boundary Element Techniques

    Full text link
    Non linear transformations are a good alternative for the numerical evaluation of singular and quasisingular integrals appearing in Boundary Element Method specially in the p-adaptive version. Some aspects of its numerical implementation in 2-D Potential codes is discussed and some examples are shown

    Optimización energética de un sistema de climatización condensado con torre de refrigeración

    Get PDF
    El aumento del consumo energético en los últimos años ha propiciado la aparición de políticas de eficiencia energética en numerosos países, cuyo principal objetivo es la disminución de las emisiones de CO2. Este incremento se ha visto afectado por el creciente uso de sistemas de climatización debido a los nuevos estándares de confort. En este ámbito, la condensación evaporativa se presentan como una de las elecciones más eficientes para la disipación de calor ya que opera con bajas temperaturas de agua, y a iguales condiciones de funcionamiento, el consumo y los costes del equipo son menores respecto a otros sistemas como los de condensación por aire. A pesar de su buen comportamiento térmico, las torres de refrigeración han sido sustituidas por sistemas secos debido a sus problemas medioambientales. Si bien el estudio de las torres se ha fundamentado principalmente en el relleno, se han llevado a cabo diversos trabajos en los que se determina su característica térmica para diferentes sistemas de distribución y separadores de gotas, pero no se han encontrado estudios que traten la influencia de diferentes configuraciones en climatización. Este trabajo modeliza en TRNSYS una torre de refrigeración para dos sistemas de distribución de agua y seis separadores de gotas, validando cada combinación a través de datos experimentales térmicos y de consumo eléctrico. Posteriormente se define una enfriadora comercial agua-agua, evaluando el punto óptimo de funcionamiento torreenfriadora para unas condiciones ambientales. Finalmente se simula una instalación de climatización en diferentes ubicaciones geográficas, definiendo un edificio de referencia atendiendo a la normativa vigente y evaluando tanto el consumo energético como el gasto de agua. Los resultados muestran un consumo mínimo para una frecuencia de giro del ventilador de la distinta a la nominal, apreciándose la influencia de los separadores de gotas y los sistemas de distribución tanto en el consumo energético final como en el gasto de agua.Este trabajo se enmarca en el Plan Nacional “Estudio para la mejora de instalaciones de energía solar térmica y enfriamiento evaporativo en edificios y centrales termosolares” (ENE2013-48696-C2-1-R)
    corecore