441 research outputs found
Evidence for the Existence of an Effective Interfacial Tension between Miscible Fluids: Isobutyric Acid-Water and 1-Butanol-Water in a Spinning-Drop Tensiometer
We report definitive evidence for an effective interfacial tension between two types of miscible fluids using spinning-drop tensiometry (SDT). Isobutyric acid (IBA) and water have an upper critical solution temperature (UCST) of 26.3 degrees C. We created a drop of the IBA-rich phase in the water-rich phase below the UCST and then increased the temperature above it. Long after the fluids have reached thermal equilibrium, the drop persists. By plotting the inverse of the drop radius cubed (r(-3)) vs the rotation rate squared (omega(2)), we confirmed that an interfacial tension exists and estimated its value. The transition between the miscible fluids remained sharp instead of becoming more diffuse, and the drop volume decreased with time. We observed droplet breakup via the Rayleigh-Tomotika instability above the UCST when the rotation rate was decreased by 80%, again demonstrating the existence of an effective inter-facial tension. When pure IBA was injected into water above the UCST, drops formed inside the main drop even as the main drop decreased in volume with time. We also studied 1-butanol in water below the solubility limit. Effective interfacial tension values measured over time were practically constant, while the interface between the two phases remains sharp as the volume of the drop declines. The effective interfacial tension was found to be insensitive to changes in temperature and always larger than the equilibrium interfacial tension. Although these results may not apply to all miscible fluids, they clearly show that an effective interfacial tension can exist and be measured by SDT for some systems
Compact 20-pass thin-disk amplifier insensitive to thermal lensing
We present a multi-pass amplifier which passively compensates for distortions
of the spherical phase front occurring in the active medium. The design is
based on the Fourier transform propagation which makes the output beam
parameters insensitive to variation of thermal lens effects in the active
medium. The realized system allows for 20 reflections on the active medium and
delivers a small signal gain of 30 with M = 1.16. Its novel geometry
combining Fourier transform propagations with 4f-imaging stages as well as a
compact array of adjustable mirrors allows for a layout with a footprint of 400
mm x 1000 mm.Comment: 7 pages, 6 figure
Theory of biopolymer stretching at high forces
We provide a unified theory for the high force elasticity of biopolymers
solely in terms of the persistence length, , and the monomer spacing,
. When the force f>\fh \sim k_BT\xi_p/a^2 the biopolymers behave as Freely
Jointed Chains (FJCs) while in the range \fl \sim k_BT/\xi_p < f < \fh the
Worm-like Chain (WLC) is a better model. We show that can be estimated
from the force extension curve (FEC) at the extension
(normalized by the contour length of the biopolymer). After validating the
theory using simulations, we provide a quantitative analysis of the FECs for a
diverse set of biopolymers (dsDNA, ssRNA, ssDNA, polysaccharides, and
unstructured PEVK domain of titin) for . The success of a specific
polymer model (FJC or WLC) to describe the FEC of a given biopolymer is
naturally explained by the theory. Only by probing the response of biopolymers
over a wide range of forces can the -dependent elasticity be fully
described.Comment: 20 pages, 4 figure
Differential cargo mobilisation within Weibel-Palade bodies after transient fusion with the plasma membrane.
Inflammatory chemokines can be selectively released from Weibel-Palade bodies (WPBs) during kiss-and-run exocytosis. Such selectivity may arise from molecular size filtering by the fusion pore, however differential intra-WPB cargo re-mobilisation following fusion-induced structural changes within the WPB may also contribute to this process. To determine whether WPB cargo molecules are differentially re-mobilised, we applied FRAP to residual post-fusion WPB structures formed after transient exocytosis in which some or all of the fluorescent cargo was retained. Transient fusion resulted in WPB collapse from a rod to a spheroid shape accompanied by substantial swelling (>2 times by surface area) and membrane mixing between the WPB and plasma membranes. Post-fusion WPBs supported cumulative WPB exocytosis. To quantify diffusion inside rounded organelles we developed a method of FRAP analysis based on image moments. FRAP analysis showed that von Willebrand factor-EGFP (VWF-EGFP) and the VWF-propolypeptide-EGFP (Pro-EGFP) were immobile in post-fusion WPBs. Because Eotaxin-3-EGFP and ssEGFP (small soluble cargo proteins) were largely depleted from post-fusion WPBs, we studied these molecules in cells preincubated in the weak base NH4Cl which caused WPB alkalinisation and rounding similar to that produced by plasma membrane fusion. In these cells we found a dramatic increase in mobilities of Eotaxin-3-EGFP and ssEGFP that exceeded the resolution of our method (∼ 2.4 µm2/s mean). In contrast, the membrane mobilities of EGFP-CD63 and EGFP-Rab27A in post-fusion WPBs were unchanged, while P-selectin-EGFP acquired mobility. Our data suggest that selective re-mobilisation of chemokines during transient fusion contributes to selective chemokine secretion during transient WPB exocytosis. Selective secretion provides a mechanism to regulate intravascular inflammatory processes with reduced risk of thrombosis
FlashCam: a fully-digital camera for the medium-sized telescopes of the Cherenkov Telescope Array
The FlashCam group is currently preparing photomultiplier-tube based cameras
proposed for the medium-sized telescopes (MST) of the Cherenkov Telescope Array
(CTA). The cameras are designed around the FlashCam readout concept which is
the first fully-digital readout system for Cherenkov cameras, based on
commercial FADCs and FPGAs as key components for the front-end electronics
modules and a high performance camera server as back-end. This contribution
describes the progress of the full-scale FlashCam camera prototype currently
under construction, as well as performance results also obtained with earlier
demonstrator setups. Plans towards the production and implementation of
FlashCams on site are also briefly presented.Comment: 8 pages, 6 figures. In Proceedings of the 34th International Cosmic
Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions
at arXiv:1508.0589
Performance Verification of the FlashCam Prototype Camera for the Cherenkov Telescope Array
The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is
planned to significantly improve upon the sensitivity and precision of the
current generation of Cherenkov telescopes. The observatory will consist of
several dozens of telescopes with different sizes and equipped with different
types of cameras. Of these, the FlashCam camera system is the first to
implement a fully digital signal processing chain which allows for a traceable,
configurable trigger scheme and flexible signal reconstruction. As of autumn
2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears
completion. First results of the ongoing system tests demonstrate that the
signal chain and the readout system surpass CTA requirements. The stability of
the system is shown using long-term temperature cycling.Comment: 5 pages, 13 figures, Proceedings of the 9th International Workshop on
Ring Imaging Cherenkov Detectors (RICH 2016), Lake Bled, Sloveni
The SST-1M camera for the Cherenkov Telescope Array
The prototype camera of the single-mirror Small Size Telescopes (SST-1M)
proposed for the Cherenkov Telescope Array (CTA) project has been designed to
be very compact and to deliver high performance over thirty years of operation.
The camera is composed of an hexagonal photo-detection plane made of custom
designed large area hexagonal silicon photomultipliers and a high throughput,
highly configurable, fully digital readout and trigger system (DigiCam). The
camera will be installed on the telescope structure at the H.
Niewodnicza{\'n}ski institute of Nuclear Physics in Krakow in fall 2015. In
this contribution, we review the steps that led to the development of the
innovative photo-detection plane and readout electronics, and we describe the
test and calibration strategy adopted.Comment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.05894; Full consortium author list at http://cta-observatory.or
The Influence of Molecular Adsorption on Elongating Gold Nanowires
Using molecular dynamics simulations, we study the impact of physisorbing
adsorbates on the structural and mechanical evolution of gold nanowires (AuNWs)
undergoing elongation. We used various adsorbate models in our simulations,
with each model giving rise to a different surface coverage and mobility of the
adsorbed phase. We find that the local structure and mobility of the adsorbed
phase remains relatively uniform across all segments of an elongating AuNW,
except for the thinning region of the wire where the high mobility of Au atoms
disrupts the monolayer structure, giving rise to higher solvent mobility. We
analyzed the AuNW trajectories by measuring the ductile elongation of the wires
and detecting the presence of characteristic structural motifs that appeared
during elongation. Our findings indicate that adsorbates facilitate the
formation of high-energy structural motifs and lead to significantly higher
ductile elongations. In particular, our simulations result in a large number of
monatomic chains and helical structures possessing mechanical stability in
excess of what we observe in vacuum. Conversely, we find that a molecular
species that interacts weakly (i.e., does not adsorb) with AuNWs worsens the
mechanical stability of monatomic chains.Comment: To appear in Journal of Physical Chemistry
Single-molecule experiments in biological physics: methods and applications
I review single-molecule experiments (SME) in biological physics. Recent
technological developments have provided the tools to design and build
scientific instruments of high enough sensitivity and precision to manipulate
and visualize individual molecules and measure microscopic forces. Using SME it
is possible to: manipulate molecules one at a time and measure distributions
describing molecular properties; characterize the kinetics of biomolecular
reactions and; detect molecular intermediates. SME provide the additional
information about thermodynamics and kinetics of biomolecular processes. This
complements information obtained in traditional bulk assays. In SME it is also
possible to measure small energies and detect large Brownian deviations in
biomolecular reactions, thereby offering new methods and systems to scrutinize
the basic foundations of statistical mechanics. This review is written at a
very introductory level emphasizing the importance of SME to scientists
interested in knowing the common playground of ideas and the interdisciplinary
topics accessible by these techniques. The review discusses SME from an
experimental perspective, first exposing the most common experimental
methodologies and later presenting various molecular systems where such
techniques have been applied. I briefly discuss experimental techniques such as
atomic-force microscopy (AFM), laser optical tweezers (LOT), magnetic tweezers
(MT), biomembrane force probe (BFP) and single-molecule fluorescence (SMF). I
then present several applications of SME to the study of nucleic acids (DNA,
RNA and DNA condensation), proteins (protein-protein interactions, protein
folding and molecular motors). Finally, I discuss applications of SME to the
study of the nonequilibrium thermodynamics of small systems and the
experimental verification of fluctuation theorems. I conclude with a discussion
of open questions and future perspectives.Comment: Latex, 60 pages, 12 figures, Topical Review for J. Phys. C (Cond.
Matt
- …