106 research outputs found

    Three-dimensional echocardiography for left ventricular quantification: fundamental validation and clinical applications

    Get PDF
    One of the earliest applications of clinical echocardiography is evaluation of left ventricular (LV) function and size. Accurate, reproducible and quantitative evaluation of LV function and size is vital for diagnosis, treatment and prediction of prognosis of heart disease. Early three-dimensional (3D) echocardiographic techniques showed better reproducibility than two-dimensional (2D) echocardiography and narrower limits of agreement for assessment of LV function and size in comparison to reference methods, mostly cardiac magnetic resonance (CMR) imaging, but acquisition methods were cumbersome and a lack of user-friendly analysis software initially precluded widespread use. Through the advent of matrix transducers enabling real-time three-dimensional echocardiography (3DE) and improvements in analysis software featuring semi-automated volumetric analysis, 3D echocardiography evolved into a simple and fast imaging modality for everyday clinical use. 3DE provides the possibility to evaluate the entire LV in three spatial dimensions during the complete cardiac cycle, offering a more accurate and complete quantitative evaluation the LV. Improved efficiency in acquisition and analysis may provide clinicians with important diagnostic information within minutes. The current article reviews the methodology and application of 3DE for quantitative evaluation of the LV, provides the scientific evidence for its current clinical use, and discusses its current limitations and potential future directions

    The impact of atrial fibrillation on prognosis in aortic stenosis

    Get PDF
    Background: Atrial fibrillation (AF) and aortic stenosis (AS) are both highly prevalent and often coexist. Various studies have focused on the prognostic value of AF in patients with AS, but rarely considered left ventricular (LV) diastolic function as a prognostic factor. Objective: To evaluate the prognostic impact of AF in patients with AS while correcting for LV diastolic function. Methods: Patients with first diagnosis of significant AS were selected and stratified according to history of AF. The endpoint was all-cause mortality. Results: In total, 2849 patients with significant AS (mean age 72 +/- 12 years, 54.8% men) were evaluated, and 686 (24.1%) had a history of AF. During a median follow-up of 60 (30-97) months, 1182 (41.5%) patients died. Ten-year mortality rate in patients with AF was 46.8% compared to 36.8% in patients with sinus rhythm (SR) (log-rank P P P = 0.026), AF was independently associated with mortality. However, when correcting for indexed left atrial volume, E/e' or both, AF was no longer independently associated with all-cause mortality. Conclusion: Patients with significant AS and AF have a reduced survival as compared to patients with SR. Nonetheless, when correcting for markers of LV diastolic function, AF was not independently associated with outcomes in patients with significant AS.</p

    Left ventricular remodelling patterns in patients with moderate aortic stenosis

    Get PDF
    Aims: Moderate aortic stenosis (AS) is associated with an increased risk of adverse events. Because outcomes in patients with AS are ultimately driven by the condition of the left ventricle (LV) and not by the valve, assessment of LV remodelling seems important for risk stratification. This study evaluated the association between different LV remodelling patterns and outcomes in patients with moderate AS.Methods and results: Patients with moderate AS (aortic valve area 1.0-1.5 cm2) were identified and stratified into four groups according to the LV remodelling pattern: normal geometry (NG), concentric remodelling (CR), concentric hypertrophy (CH), or eccentric hypertrophy (EH). Clinical outcomes were defined as all-cause mortality and a composite endpoint of all-cause mortality and aortic valve replacement (AVR). Of 1931 patients with moderate AS (age 73 ± 10 years, 52% men), 344 (18%) had NG, 469 (24%) CR, 698 (36%) CH, and 420 (22%) EH. Patients with CH and EH showed higher 3-year mortality rates (28% and 32%, respectively) when compared with patients with NG (19%) (P Conclusion: In patients with moderate AS, those who develop CH already have an increased risk of all-cause mortality. Assessment of the LV remodelling patterns may identify patients at higher risk of adverse events, warranting closer surveillance, and possibly earlier intervention.</p

    Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience

    Get PDF
    <p>Abstract</p> <p>Aim of the work</p> <p>To evaluate the feasibility and possible additional value of transthoracic real-time three-dimensional echocardiography (RT3D-TTE) for the assessment of cardiac structures as compared to 2D-TTE.</p> <p>Methods</p> <p>320 patients (mean age 45 ± 8.4 years, 75% males) underwent 2D-TTE and RT3D-TTE using 3DQ-Q lab software for offline analysis. Volume quantification and functional assessment was performed in 90 patients for left ventricle and in 20 patients for right ventricle. Assessment of native (112 patients) and prosthetic (30 patients) valves morphology and functions was performed. RT3D-TTE was performed for evaluation of septal defects in 30 patients and intracardiac masses in 52 patients.</p> <p>Results</p> <p>RT3D-TTE assessment of left ventricle was feasible and reproducible in 86% of patients while for right ventricle, it was (55%). RT3D-TTE could define the surface anatomy of mitral valve optimally (100%), while for aortic and tricuspid was (88% and 81% respectively). Valve area could be planimetered in 100% for the mitral and in 80% for the aortic. RT3D-TTE provided a comprehensive anatomical and functional evaluation of prosthetic valves. RT3D-TTE enface visualization of septal defects allowed optimal assessment of shape, size, area and number of defects and evaluated the outcome post device closure. RT3D-TTE allowed looking inside the intracardiac masses through multiple sectioning, valuable anatomical delineation and volume calculation.</p> <p>Conclusion</p> <p>Our initial experience showed that the use of RT3D-TTE in the assessment of cardiac patients is feasible and allowed detailed anatomical and functional assessment of many cardiac disorders.</p

    Reverse left ventricular remodeling is more likely in non ischemic cardiomyopathy patients upgraded to biventricular stimulation after chronic right ventricular pacing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Chronic right ventricular (RV) apical pacing may lead to left ventricular (LV) dyssynchrony and LV dysfunction. In heart failure due to RV pacing, upgrading to biventricular stimulation (CRT) can improve NYHA Class and LV function. A proportion of patients do not respond to upgrading. Aim was to assess whether etiology of LV dysfunction accounts for responses to CRT in RV-paced patients.</p> <p>Methods</p> <p>Sixty-two patients treated by CRT, under RV pacing from 50.2 ± 5.4 months, were studied. Cause of LV dysfunction was non-ischemic (NIC) in 28 and ischemic cardiomyopathy (IC) in 34 patients. Clinical and conventional echocardiographic parameters were available within 1 month before RV pacing, within 1 month before CRT and at 12 ± 2 months of follow-up (FU).</p> <p>Results</p> <p>Decreased LVEF (from 37.0 ± 8.8 to 25.6 ± 6.1%, p <0.001), increased LV end-systolic dimensions (LVESD) (from 48.1 ± 8.6 to 55.2 ± 7.9 mm, p <0.001) and worsened NYHA Class (from 1.9 ± 1.1 to 3.2 ± .6, p < 0.005) were found before CRT, compared to pre RV-pacing. After CRT, 44/62 patients showed a ≥ 1 NYHA Class improvement; >10% decrease in LVESD was observed in 24 patients: 5 with IC, 19 with NIC (p < .0.001). The association between cause of LV dysfunction with >10% decrease in LVESD remained highly significant (p < 0.001) adjusting for pre-CRT QRS duration, NYHA Class, LVEF, LVESD, treatment or RV pacing duration.</p> <p>Conclusions</p> <p>CRT improves functional class even after long-lasting pacing. Reverse remodeling is evident in a small population, more likely with NIC.</p

    Automated left ventricular diastolic function evaluation from phase-contrast cardiovascular magnetic resonance and comparison with Doppler echocardiography

    Get PDF
    International audienceBACKGROUND: Early detection of diastolic dysfunction is crucial for patients with incipient heart failure. Although this evaluation could be performed from phase-contrast (PC) cardiovascular magnetic resonance (CMR) data, its usefulness in clinical routine is not yet established, mainly because the interpretation of such data remains mostly based on manual post-processing. Accordingly, our goal was to develop a robust process to automatically estimate velocity and flow rate-related diastolic parameters from PC-CMR data and to test the consistency of these parameters against echocardiography as well as their ability to characterize left ventricular (LV) diastolic dysfunction. RESULTS: We studied 35 controls and 18 patients with severe aortic valve stenosis and preserved LV ejection fraction who had PC-CMR and Doppler echocardiography exams on the same day. PC-CMR mitral flow and myocardial velocity data were analyzed using custom software for semi-automated extraction of diastolic parameters. Inter-operator reproducibility of flow pattern segmentation and functional parameters was assessed on a sub-group of 30 subjects. The mean percentage of overlap between the transmitral flow segmentations performed by two independent operators was 99.7 ± 1.6%, resulting in a small variability ( 0.71) and receiver operating characteristic (ROC) analysis revealed their ability to separate patients from controls, with sensitivity > 0.80, specificity > 0.80 and accuracy > 0.85. Slight superiority in terms of correlation with echocardiography (r = 0.81) and accuracy to detect LV abnormalities (sensitivity > 0.83, specificity > 0.91 and accuracy > 0.89) was found for the PC-CMR flow-rate related parameters. CONCLUSIONS: A fast and reproducible technique for flow and myocardial PC-CMR data analysis was successfully used on controls and patients to extract consistent velocity-related diastolic parameters, as well as flow rate-related parameters. This technique provides a valuable addition to established CMR tools in the evaluation and the management of patients with diastolic dysfunction
    corecore