46 research outputs found

    Effect of Setup Configurations of Split Computer Keyboards on Wrist Angle

    Get PDF
    Alternative computer keyboards whose halves can be slanted toward each other can reduce a risk factor (ulnar deviation) for work-related musculoskeletal disorders (WMSDs) affecting the upper limbs. Two questions that computer keyboard operators face when using keyboards that can be separated into halves (split keyboards) are: (1) At what angle should the keyboard halves be opened? and (2) At what distance apart should the keyboard halves be placed? The objective of this study was to investigate the effects of the opening angle and separation distance between halves of a split keyboard on wrist ulnar deviation and typing efficiency. Methods. Eleven experienced computer keyboard operators participated in this study and used a split keyboard that was set up in a conventional (nonsplit) format and also in 3 alternative configurations: (1) centers of keyboard halves were separated at 20-cm distance, (2) keyboard halves were separated half of the distance of shoulder width, and (3) keyboard halves were separated at shoulder width distance. Results. The 3 alternative configurations resulted in ulnar deviation of both wrists that were less than ulnar deviation from typing on a conventional setup. There were no differences in ulnar deviations among the 3 alternative configurations. Discussion and Conclusion. The results of this research provide physical therapists and ergonomists with a set of configurations of a split keyboard that they can recommend to their patients or clients. All of the alternative configurations of the split keyboard are beneficial in promoting a neutral wrist position, which theoretically would decrease exposure to WMSDs such as tenosynovitis in the wrist and carpal tunnel syndrome. [Marklin RW, Simoneau GG. Effect of setup configurations of split computer keyboards on wrist angle. Phys Ther. 2001;81:1038 –1048.

    Effect of Computer Keyboard Slope on Wrist Position and Forearm Electromyography of Typists Without Musculoskeletal Disorders

    Get PDF
    Positioning a computer keyboard with a downward slope reduces wrist extension needed to use the keyboard and has been shown to decrease pressure in the carpal tunnel. However, whether a downward slope of the keyboard reduces electromyographic (EMG) activity of the forearm muscles, in particular the wrist extensors, is not known. Subjects and Methods. Sixteen experienced typists participated in this study and typed on a conventional keyboard that was placed on slopes. Electromyographic activity of the extensor carpi ulnaris (ECU), flexor carpi ulnaris (FCU), and flexor carpi radialis (FCR) muscles was measured with surface electrodes, while the extension and ulnar deviation angles of the right and left wrists were measured with electrogoniometers. Results. Wrist extension angle decreased from approximately 12 degrees of extension while typing on a keyboard with a 7.5-degree slope to 3 degrees of flexion with the keyboard at a slope of –15 degrees. Although the differences were in the range of 1% to 3% of maximum voluntary contraction (MVC), amplitude probability distribution function (APDF) of root-mean-square EMG data points from the ECU, FCU, and FCR muscles varied across keyboard slopes. Discussion and Conclusion. Wrist extension decreased as the keyboard slope decreased. Furthermore, a slight decrease in percentage of MVC of the ECU muscle was noted as the keyboard slope decreased. Based on biomechanical modeling and published work on carpal tunnel pressure, both of these findings appear to be positive with respect to comfort and fatigue, but the exact consequences of these findings on the reduction or prevention of injuries have yet to be determined. The results may aid physical therapists and ergonomists in their evaluations of computer keyboard workstations and in making recommendations for interventions with regard to keyboard slope angle. [Simoneau GG, Marklin RW, Berman JE. Effect of computer keyboard slope on wrist position and forearm electromyography of typists without musculoskeletal disorders. Phys Ther. 2003;83:816–830.

    Biomechanical Effects of Mobile Computer Location in a Vehicle Cab

    Get PDF
    Objective: The objective of this research is to determine the best location to place a conventional mobile computer supported by a commercially available mount in a light truck cab. Background: U.S. and Canadian electric utility companies are in the process of integrating mobile computers into their fleet vehicle cabs. There are no publications on the effect of mobile computer location in a vehicle cab on biomechanical loading, performance, and subjective assessment. Method: The authors tested four locations of mobile computers in a light truck cab in a laboratory study to determine how location affected muscle activity of the lower back and shoulders; joint angles of the shoulders, elbows, and wrist; user performance; and subjective assessment. A total of 22 participants were tested in this study. Results: Placing the mobile computer closer to the steering wheel reduced low back and shoulder muscle activity. Joint angles of the shoulders, elbows, and wrists were also closer to neutral angle. Biomechanical modeling revealed substantially less spinal compression and trunk muscle force. In general, there were no practical differences in performance between the locations. Subjective assessment indicated that users preferred the mobile computer to be as close as possible to the steering wheel. Conclusion: Locating the mobile computer close to the steering wheel reduces risk of injuries, such as low back pain and shoulder tendonitis. Application: Results from the study can guide electric utility companies in the installation of mobile computers into vehicle cabs. Results may also be generalized to other industries that use trucklike vehicles, such as construction

    Stable Spheromak Formation By Merging In An Oblate Flux Conserver

    Get PDF
    An axisymmetric spheromak formed by the dynamic merging of two smaller spheromaks of the same magnetic helicity in the Swarthmore Spheromak Experiment (SSX) [M. R. Brown, Phys. Plasmas 6, 1717 (1999)] has been observed and characterized. The spheromak is formed in an oblate (tilt stable), trapezoidal, 6 mm wall copper flux conserver in SSX, which is 0.5 m in diameter and L=0.4 m in length at its largest dimensions. This configuration is formed by cohelicity merging of two spheromaks (either both right-handed or both left-handed) in which the merging poloidal fluxes are parallel (i.e., no field reversal for reconnection to occur initially). After a period of dynamic and nonaxisymmetric activity, the configuration ultimately relaxes to an axisymmetric state. A nonaxisymmetric tilted state, very close in total energy to the axisymmetric state, is also sometimes observed. This configuration is characterized by a suite of magnetic probe arrays for magnetic structure B(r,t), ion Doppler spectroscopy for T(i) and flow, and interferometry for ne. The magnetic structures of both states match well to computed eigenstates. (C) 2010 American Institute of Physics. [doi:10.1063/1.3334324

    Observation Of A Helical Self-Organized State In A Compact Toroidal Plasma

    Get PDF
    A nonaxisymmetric stable magnetohydrodynamic (MHD) equilibrium within a prolate cylindrical conducting boundary has been produced experimentally. It has m=1 azimuthal symmetry, helical distortion, and flat lambda profile, all in agreement with the computed magnetically relaxed minimum magnetic energy Taylor state. Despite varied initial conditions determined by two helicity injectors on the device, this same equilibrium consistently emerges as the final state. These results therefore describe a new example of self-organization in an MHD plasma

    Effect of Keyswitch Design of Desktop and Notebook Keyboards Related to Key Stiffness and Typing Force

    Get PDF
    This study aimed to compare and analyse rubber-dome desktop, spring column desktop and notebook keyboards in terms of key stiffness and fingertip typing force. The spring-column keyboard resulted in the highest mean peak contact force (0.86N), followed by the rubber dome desktop (0.68N) and the notebook (0.59N). All these differences were statistically significant. Likewise, the spring-column keyboard registered the highest fingertip typing force and the notebook keyboard the lowest. A comparison of forces showed the notebook (rubber dome) keyboard had the highest fingertip-to-peak contact force ratio (overstrike force), and the spring-column generated the least excess force (as a ratio of peak contact force). The results of this study could aid in optimizing computer key design that could possibly reduce subject discomfort and fatigue

    Observation Of A Nonaxisymmetric Magnetohydrodynamic Self-Organized State

    Get PDF
    A nonaxisymmetric stable magnetohydrodynamic(MHD) equilibrium within a prolate cylindrical conducting boundary has been produced experimentally at Swarthmore Spheromak Experiment (SSX) [M. R. Brown et al., Phys. Plasmas6, 1717 (1999)]. It has m=1toroidal symmetry, helical distortion, and flat λ profile. Each of these observed characteristics are in agreement with the magnetically relaxed minimum magnetic energy Taylor state. The Taylor state is computed using the methods described by A. Bondeson et al. [Phys. Fluids24, 1682 (1981)] and by J. M. Finn et al. [Phys. Fluids24, 1336 (1981)] and is compared in detail to the measured internal magnetic structure. The lifetime of this nonaxisymmetric compact torus (CT) is comparable to or greater than that of the axisymmetric CTs produced at SSX; thus suggesting confinement is not degraded by its nonaxisymmetry. For both one- and two-spheromak initial state plasmas, this same equilibrium consistently emerges as the final state

    Utilizing computed tomography volumetry for size matching prior to lung transplantation: A case series

    Get PDF
    BACKGROUND: Appropriate size matching between donor and recipient is critical for successful pulmonary transplantation. Although surrogate measurements such as height and gender are often utilized to approximate predicted lung volume, these methods provide only a gross estimation with wide variability and poor predictive value. CASE DESCRIPTION: A single center exploratory study was conducted in which four patients underwent lung transplantation (LT) with pre-operative computed tomography (CT) volumetry obtained in both the donor and recipient to facilitate decision making regarding organ size and suitability. In four cases in which CT volumetry was used, the lung volumes calculated using surrogate measurements significantly overestimated both donor and recipient lung volumes quantified by CT volumetric analysis. All recipients underwent successful LT without necessary graft downsizing. CONCLUSIONS: This is an initial report of prospectively utilizing CT volumetry as an adjunct to decision-making regarding suitability of donor lungs. In these cases, CT volumetry facilitated the confident acceptance of donor lungs that were initially predicted to be oversized based on other clinical measures

    Economic evaluation of the specialized donor care facility for thoracic organ donor management

    Get PDF
    Background: Over the last decade two alternative models of donor care have emerged in the United States: the conventional model, whereby donors are managed at the hospital where brain death occurs, and the specialized donor care facility (SDCF), in which brain dead donors are transferred to a SDCF for medical optimization and organ procurement. Despite increasing use of the SDCF model, its cost-effectiveness in comparison to the conventional model remains unknown. Methods: We performed an economic evaluation of the SDCF and conventional model of donor care from the perspective of U.S. transplant centers over a 2-year study period. In this analysis, we utilized nationwide data from the Scientific Registry of Transplant Recipients and controlled for donor characteristics and patterns of organ sharing across the nation\u27s organ procurement organizations (OPOs). Subgroup analysis was performed to determine the impact of the SDCF model on thoracic organ transplants. Results: A total of 38,944 organ transplants were performed in the U.S. during the study period from 13,539 donors with an observed total organ cost of 1.36billion.IfeveryOPOassumedthecostandeffectivenessoftheSDCFmodel,apredicted39,155organtransplants(+211)wouldhavebeenperformedwithapredictedtotalorgancostof1.36 billion. If every OPO assumed the cost and effectiveness of the SDCF model, a predicted 39,155 organ transplants (+211) would have been performed with a predicted total organ cost of 1.26 billion (-100million).SubgroupanalysisofthoracicorgansrevealedthattheSDCFmodelwouldleadtoapredicted156additionaltransplantswithacostsavingof100 million). Subgroup analysis of thoracic organs revealed that the SDCF model would lead to a predicted 156 additional transplants with a cost saving of 24.6 million. Conclusions: The U.S. SDCF model may be a less costly and more effective means of multi-organ donor management, particularly for thoracic organ donors, compared to the conventional hospital-based model

    Carpal tunnel syndrome and the use of computer mouse and keyboard: A systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This review examines evidence for an association between computer work and carpal tunnel syndrome (CTS).</p> <p>Methods</p> <p>A systematic review of studies of computer work and CTS was performed. Supplementary, longitudinal studies of low force, repetitive work and CTS, and studies of possible pathophysiological mechanisms were evaluated.</p> <p>Results</p> <p>Eight epidemiological studies of the association between computer work and CTS were identified. All eight studies had one or more limitation including imprecise exposure and outcome assessment, low statistical power or potentially serious biases. In three of the studies an exposure-response association was observed but because of possible misclassification no firm conclusions could be drawn. Three of the studies found risks below 1. Also longitudinal studies of repetitive low-force non-computer work (n = 3) were reviewed but these studies did not add evidence to an association. Measurements of carpal tunnel pressure (CTP) under conditions typically observed among computer users showed pressure values below levels considered harmful. However, during actual mouse use one study showed an increase of CTP to potentially harmful levels. The long term effects of prolonged or repeatedly increased pressures at these levels are not known, however.</p> <p>Conclusion</p> <p>There is insufficient epidemiological evidence that computer work causes CTS.</p
    corecore