140 research outputs found
Multiplicity fluctuations in nuclear collisions at 158 A GeV
System size dependence of multiplicity fluctuations of charged particles
produced in nuclear collisions at 158 A GeV was studied in the NA49 CERN
experiment. Results indicate a non-monotonic dependence of the scaled variance
of the multiplicity distribution with a maximum for semi-peripheral Pb+Pb
interactions with number of projectile participants of about 35. This effect is
not observed in a string-hadronic model of nuclear collision HIJING.Comment: Presented at "Focus on Multiplicity", 17-19 of June, Bari, Ital
System size and centrality dependence of the balance function in A+A collisions at sqrt[sNN]=17.2 GeV
Electric charge correlations were studied for p+p, C+C, Si+Si, and centrality selected Pb+Pb collisions at sqrt[sNN]=17.2 GeV with the NA49 large acceptance detector at the CERN SPS. In particular, long-range pseudorapidity correlations of oppositely charged particles were measured using the balance function method. The width of the balance function decreases with increasing system size and centrality of the reactions. This decrease could be related to an increasing delay of hadronization in central Pb+Pb collisions
System size and centrality dependence of the balance function in A + A collisions at sqrt s NN = 17.2 GeV
Electric charge correlations were studied for p+p, C+C, Si+Si and centrality selected Pb+Pb collisions at sqrt s_NN = 17.2$ GeV with the NA49 large acceptance detector at the CERN-SPS. In particular, long range pseudo-rapidity correlations of oppositely charged particles were measured using the Balance Function method. The width of the Balance Function decreases with increasing system size and centrality of the reactions. This decrease could be related to an increasing delay of hadronization in central Pb+Pb collisions
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
We describe the design and performance the calorimeter systems used in the
ECCE detector design to achieve the overall performance specifications
cost-effectively with careful consideration of appropriate technical and
schedule risks. The calorimeter systems consist of three electromagnetic
calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and
two hadronic calorimeters. Key calorimeter performances which include energy
and position resolutions, reconstruction efficiency, and particle
identification will be presented.Comment: 19 pages, 22 figures, 5 table
ECCE Sensitivity Studies for Single Hadron Transverse Single Spin Asymmetry Measurements
We performed feasibility studies for various single transverse spin
measurements that are related to the Sivers effect, transversity and the tensor
charge, and the Collins fragmentation function. The processes studied include
semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions
and kaons) were detected in addition to the scattered DIS lepton. The data were
obtained in {\sc pythia}6 and {\sc geant}4 simulated e+p collisions at 18 GeV
on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector
configuration. Typical DIS kinematics were selected, most notably
GeV, and cover the range from to . The single spin
asymmetries were extracted as a function of and , as well as the
semi-inclusive variables , and . They are obtained in azimuthal moments
in combinations of the azimuthal angles of the hadron transverse momentum and
transverse spin of the nucleon relative to the lepton scattering plane. The
initially unpolarized MonteCarlo was re-weighted in the true kinematic
variables, hadron types and parton flavors based on global fits of fixed target
SIDIS experiments and annihilation data. The expected statistical
precision of such measurements is extrapolated to 10 fb and potential
systematic uncertainties are approximated given the deviations between true and
reconstructed yields. The impact on the knowledge of the Sivers functions,
transversity and tensor charges, and the Collins function has then been
evaluated in the same phenomenological extractions as in the Yellow Report. The
impact is found to be comparable to that obtained with the parameterized Yellow
Report detector and shows that the ECCE detector configuration can fulfill the
physics goals on these quantities.Comment: 22 pages, 22 figures, to be submitted to joint ECCE proposal NIM-A
volum
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
The ECCE detector has been recommended as the selected reference detector for
the future Electron-Ion Collider (EIC). A series of simulation studies have
been carried out to validate the physics feasibility of the ECCE detector. In
this paper, detailed studies of heavy flavor hadron and jet reconstruction and
physics projections with the ECCE detector performance and different magnet
options will be presented. The ECCE detector has enabled precise EIC heavy
flavor hadron and jet measurements with a broad kinematic coverage. These
proposed heavy flavor measurements will help systematically study the
hadronization process in vacuum and nuclear medium especially in the
underexplored kinematic region.Comment: Open heavy flavor studies with the EIC reference detector design by
the ECCE consortium. 11 pages, 11 figures, to be submitted to the Nuclear
Instruments and Methods
ECCE unpolarized TMD measurements
We performed feasibility studies for various measurements that are related to
unpolarized TMD distribution and fragmentation functions. The processes studied
include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons
(pions and kaons) were detected in addition to the scattered DIS lepton. The
single hadron cross sections and multiplicities were extracted as a function of
the DIS variables and , as well as the semi-inclusive variables ,
which corresponds to the momentum fraction the detected hadron carries relative
to the struck parton and , which corresponds to the transverse momentum of
the detected hadron relative to the virtual photon. The expected statistical
precision of such measurements is extrapolated to accumulated luminosities of
10 fb and potential systematic uncertainties are approximated given the
deviations between true and reconstructed yields.Comment: 12 pages, 9 figures, to be submitted in joint ECCE proposal NIM-A
volum
- …