    Shaping ability of Reciproc and TF Adaptive systems in severely curved canals of rapid microCT-based prototyping molar replicas

    Get PDF
    Objective: To evaluate the shaping ability of Reciproc and Twisted-File Adaptive systems in rapid prototyping replicas. Material and Methods: Two mandibular molars showing S-shaped and 62-degree curvatures in the mesial root were scanned by using a microcomputed tomography (μCT) system. The data were exported in the stereolitograhic format and 20 samples of each molar were printed at 16 µm resolution. The mesial canals of 10 replicas of each specimen were prepared with each system. Transportation was measured by overlapping radiographs taken before and after preparation and resin thickness after instrumentation was measured by μCT. Results: Both systems maintained the original shape of the apical third in both anatomies (P>;0.05). Overall, considering the resin thickness in the 62-degree replicas, no statistical difference was found between the systems (P>;0.05). In the S-shaped curvature replica, Reciproc significantly decreased the thickness of the resin walls in comparison with TF Adaptive. Conclusions: The evaluated systems were able to maintain the original shape at the apical third of severely curved mesial canals of molar replicas

    Radiopacity evaluation of root-end filling materials by digitization of images

    Get PDF
    The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compared to that of the aluminum stepwedge using VIXWIN 2000 software in millimeters of aluminum (mm Al). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Radiopacity values varied from 3 mm Al to 5.9 mm Al. Sealer 26 and IRM presented the highest radiopacity values (

    Effect of ultrasonic streaming on intra-dentinal disinfection and penetration of calcium hydroxide paste in endodontic treatment

    Get PDF
    Objective The antimicrobial effect of ultrasonic agitation of calcium hydroxide (CH) pastes in infected bovine dentin and their penetrability were evaluated using confocal laser scanning microscopy (CLSM) and microbiological culture. Material and Methods Fifty-two bovine teeth were infected with Enterococcus faecalis using a new contamination protocol; then they received CH paste and were divided into groups with or without ultrasound. Ultrasonic agitation was conducted for 1 min with a plain point insert. After 15 d, the CLSM analyzed the viable and dead bacteria with Live and Dead assay. The dentinal wall debris was collected by burs, and the colony forming units (CFU/mL) were counted. The penetrability of the paste inside dentinal tubules was tested using the B-rodamine dye. Results The calcium hydroxide paste showed better results with the use of ultrasonic agitation (

    Influence of cervical preflaring and root canal preparation on the fracture resistance of endodontically treated teeth

    Get PDF
    Background: Evaluate the fracture resistance of endodontically treated teeth after cervical preflaring and root canal preparation and to assess the volume of the root canal and the amount of remaining root dentin before and after cervical preflaring. Methods: Forty-four mandibular incisors were selected using micro-CT scanning and distributed into 4 groups (n = 11) according to the instrument used for cervical preflaring: control group - no cervical preflaring; Gates Glidden – burs size #2 and #3; WXN – 25.07 Navigator instrument; and Easy – 25.08 ProDesign S instrument. Coronal opening was performed, and the canals were prepared with Wave One Gold Primary and filled with an epoxy-resin based sealer and gutta-percha cones. Micro-CT scans were performed before and after root canal instrumentation. All images were reconstructed and assessed for the thickness of mesial and distal root dentin at 3 mm and 5 mm from the cement -enamel junction and for the volume of cervical portion of the canal after preparation. Fracture resistance test was performed applying compressive loads at a crosshead speed of 0.5 mm/min, applied on the palatal aspect of specimens at 135° along the long axis of the tooth. The data were analyzed using ANOVA and Tukey’s test (P = .05). Results: Cervical preflaring and canal preparation reduced the dentin thickness (P < .05) and increased the canal volume (P < .05) in all groups at 3 mm an 5 mm. Cervical preflaring with Gates Gliden burs reduced the fracture resistance of endodontically treated teeth (P < .05). Conclusions: All instruments reduced the dentin thickness and increased the canal volume in the cervical at 3 mm and 5 mm. Gates Glidden reduced fracture resistance of mandibular incisors submitted to cervical preflaring, whereas NiTi instruments did not

    Shaping ability of Reciproc and TF Adaptive systems in severely curved canals of rapid microCT-based prototyping molar replicas

    Get PDF
    Objective: To evaluate the shaping ability of Reciproc and Twisted-File Adaptive systems in rapid prototyping replicas. Material and Methods: Two mandibular molars showing S-shaped and 62-degree curvatures in the mesial root were scanned by using a microcomputed tomography (μCT) system. The data were exported in the stereolitograhic format and 20 samples of each molar were printed at 16 µm resolution. The mesial canals of 10 replicas of each specimen were prepared with each system. Transportation was measured by overlapping radiographs taken before and after preparation and resin thickness after instrumentation was measured by μCT. Results: Both systems maintained the original shape of the apical third in both anatomies (P>0.05). Overall, considering the resin thickness in the 62-degree replicas, no statistical difference was found between the systems (P>0.05). In the S-shaped curvature replica, Reciproc significantly decreased the thickness of the resin walls in comparison with TF Adaptive. Conclusions: The evaluated systems were able to maintain the original shape at the apical third of severely curved mesial canals of molar replicas

    Apical sealing of root canal fillings performed with five different endodontic sealers: analysis by fluid filtration

    No full text
    OBJECTIVES: To evaluate the sealing ability of five root canal sealers, including two experimental cements (MBP and MTA-Obtura) using the fluid filtration method. MATERIAL AND METHODS: Teeth were divided into 5 study groups: G1-AH Plus; G2-Acroseal; G3Sealapex; G4-MBP; G5-MTA-Obtura; and two controls. Chemical-mechanical preparation was performed with ProFile rotary nickel-titanium instruments 1 mm short of the apical foramen. The sealing ability was evaluated by fluid filtration at 15, 30, and 60 days. RESULTS: The statistical analysis showed significant difference between the materials at different periods (p<0.05). AH Plus and MBP had similar leakage values at 15 and 60 days, alternating with significant reduction at 30 days, while the other materials showed progressive increase in leakage values. Acroseal and Sealapex presented the best results at 15 days and the worst at 60 days. CONCLUSIONS: All sealers evaluated presented fluid leakage, with AH Plus and MBP showing the best results at the end of the experimental period. Acroseal, Sealapex, and MTA-Obtura presented increase in leakage values at longer observation periods

    Testes de biocompatibilidade in vitro de duas formas comerciais do agregado de trióxido mineral

    No full text
    Recently, regular and white mineral trioxide aggregate (MTA) are being used in Dentistry as retrofilling materials. Genotoxicity and cytotoxicity tests form an important part of cancer research and risk assessment of potential carcinogens. Thus, the goal of this study was to examine the genotoxicity and cytotoxicity of regular and white MTA in vitro by the single cell gel (comet) assay and trypan blue exclusion test, respectively. Mouse lymphoma cells were exposed to two presentation forms of MTA at final concentrations ranging from 1 to 1,000 μg/mL for 3 h at 37°C. The results showed that both compounds tested did not produce genotoxic effects at all concentrations evaluated. Likewise, no statistically significant differences (p > 0.05) were observed in cytotoxicity. Taken together, our results suggest that regular and white MTA are not genotoxins and are not able to interfere in cellular viability as assessed by single cell gel (comet) assay and trypan blue assay, respectively