    Variability of cardioinhibition in vasovagal syncope:differences between subgroups during cardioinhibition and beyond

    Get PDF
    Purpose: We compared hemodynamic parameters between subjects with marked, intermediate and minimal cardioinhibition during vasovagal syncope.Methods: The study included subjects with a decrease in heart rate while experiencing a complete vasovagal syncope during tilt-table testing. The subjects were classified as having marked, intermediate or minimal cardioinhibition, based on tertile values of the decrease in heart rate. Hemodynamic parameters between these groups were compared before tilt in the supine position, shortly after tilt and during cardioinhibition. Results:A total of 149 subjects with a median age of 43 (interquartile range 24–60) years were included in the study. Among the three groups with different levels of cardioinhibition, the highest heart rate was observed in subjects with marked cardioinhibition both before and shortly after tilt and at the start of cardioinhibition. The heart rate decrease in these subjects was both larger and faster compared to subjects with minimal and intermediate cardioinhibition. Conclusion: Subjects with marked cardioinhibition have both a larger and faster decrease in heart rate compared to subjects with intermediate and minimal cardioinhibition, as early as from the start of cardioinhibition. Marked cardioinhibition is related to differences in hemodynamic profiles already present well before the start of cardioinhibition.</p

    Patient preference regarding assessment of clinical follow-up after percutaneous coronary intervention: the PAPAYA study

    Get PDF
    Aims: To keep patients in long-term clinical follow-up programmes after percutaneous coronary intervention (PCI), knowledge of the patient-preferred mode for follow-up assessment is crucial. We systematically assessed patient preference, and explored potential relationships with age and gender.Methods and results: In the prospective, observational PAPAYA study (ClinicalTrials.gov: NCT02189070), 2,566 patients, treated by PCI between June 2008 and May 2012, were invited to participate in a postal survey on the patient-preferred mode (postal questionnaire, telephone or e-mail consultation) and frequency of follow-up assessment. A total of 1,797 (70.0%) patients responded. The vast majority preferred completing postal questionnaires (1,248 [69.9%]) as compared to telephone (240 [13.4%]) or e-mail-based approaches (227 [12.7%]) (p<0.001). With increasing age, there was a gradual decline in preference for e-mail (p<0.001); the youngest patients (≤60 years) preferred e-mail-based follow-up more often than the oldest (21.1% vs. 3.1%). Nevertheless, 79.9% of the youngest preferred to be approached in ways other than by e-mail. Women more often preferred approaches other than e-mail (94.1% vs. 87.3%, p<0.001).Conclusions: Patients showed a distinct preference for completing postal questionnaires rather than being approached by telephone or e-mail. Younger patients accepted e-mail-based follow-up more often, but the majority of the youngest patients still preferred approaches other than by e-mail - See more at: http://www.pcronline.com/eurointervention/ahead-of-print/201510-06/patient-preference-regarding-assessment-of-clinical-follow-up-after-percutaneous-coronary-intervention-the-papaya-study

    Coronary–aortic interaction during ventricular isovolumic contraction

    Get PDF
    In earlier work, we suggested that the start of the isovolumic contraction period could be detected in arterial pressure waveforms as the start of a temporary pre-systolic pressure perturbation (AICstart, start of the Arterially detected Isovolumic Contraction), and proposed the retrograde coronary blood volume flow in combination with a backwards traveling pressure wave as its most likely origin. In this study, we tested this hypothesis by means of a coronary artery occlusion protocol. In six Yorkshire × Landrace swine, we simultaneously occluded the left anterior descending (LAD) and left circumflex (LCx) artery for 5 s followed by a 20-s reperfusion period and repeated this sequence at least two more times. A similar procedure was used to occlude only the right coronary artery (RCA) and finally all three main coronary arteries simultaneously. None of the occlusion protocols caused a decrease in the arterial pressure perturbation in the aorta during occlusion (P > 0.20) nor an increase during reactive hyperemia (P > 0.22), despite a higher deceleration of coronary blood volume flow (P = 0.03) or increased coronary conductance (P = 0.04) during hyperemia. These results show that the pre-systolic aortic pressure perturbation does not originate from the coronary arteries

    TCT-251 Abnormal glucose metabolism and adverse event rates 12 months after treatment with contemporary drug-eluting stents:Insights from the BIO-RESORT Silent Diabetes study

    Get PDF
    BACKGROUND: Patients with abnormal glucose metabolism, including patients with undetected and thus untreated diabetes, may have higher event risks after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES). We assessed the prevalence and clinical impact of abnormal glucose metabolism in allcomer patients without previously known diabetes undergoing PCI. METHODS: The BIO-RESORT Silent Diabetes study, performed at Thoraxcentrum Twente, is a substudy of the randomized BIO-RESORT trial (NCT01674803). We performed an additional analysis identifying patients with an abnormal glucose metabolism by means of oral glucose tolerance testing (OGTT), and assessment of glycated hemoglobin A1c (HbA1c) with fasting plasma glucose (FPG) and clinical outcome at 12 months. RESULTS: Assessment of glucose metabolism revealed that of the 988 participants a total 330 (33.4%) patients had an abnormal metabolism, while 658 (66.6%) patients had a normal metabolism. Patients with abnormal glucose metabolism showed higher rates of the primary endpoint Target Vessel Failure (6.4% vs. 2.7%; p0.01), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Multivariate analysis demonstrated that an abnormal glucose metabolism independently predicted adverse event risk (HR 2.2, 95%-CI:1.2-4.2). CONCLUSION: Abnormal glucose metabolism was detected in one out of three PCI all-comer patients and independently associated with a more than 2-fold higher event risk. Future intervention studies should determine whether meaningful benefits may accrue from routine glycaemia testing in such patients

    TCT-588 2-Year Clinical Outcome of the Randomized, Multicenter DUTCH PEERS (TWENTE II) Trial, Comparing Cobalt-Chromium Zotarolimus-Eluting Resolute Integrity Stents and Platinum-Chromium Everolimus-Eluting Promus Element Stents in “All-Comer” Patients

    Get PDF
    Background: The multicenter, prospective, randomized, single-blinded, investigator-initiated DUTCH PEERS (TWENTE II) “All Comers” Trial demonstrated at 1-year follow-up the non-inferiority of third-generation Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, CA) versus Promus Element everolimus-eluting stents (Boston Scientific, Natick, MA), based on a similar incidence of the primary endpoint target vessel failure (TVF), a composite of cardiac death, target vessel revascularization (TVR), or myocardial infarction (MI). No other follow-up data beyond 12 months have been published from a randomized head-to-head comparison of both stents. Methods: In 4 study centers in the Netherlands, 1,811 patients were 1:1 randomly assigned to treatment with one of both stents. Patients with any clinical syndrome, any lesion type, and any number of lesions or vessels to be treated were included. Study monitoring and clinical event adjudication were performed by two independent Dutch contract research organizations (Diagram, Zwolle, and Cardialysis, Rotterdam, respectively). Results: DUTCH PEERS examines an all-comer patient population that included 59% of patients with acute coronary syndromes (20% of all patients presented with an acute STEMI) and 66% of patients with complex target lesions. We will compare for both stent groups the 2-year incidence of TVF (primary endpoint) and various secondary endpoints, including individual components of the primary endpoint, the incidence of stent thrombosis, and other composite endpoints, such as target lesion failure, major adverse cardiac events, and the patient-oriented composite endpoint. In addition, we will report the outcome of patients with longitudinal stent deformation after discontinuation of dual anti-platelet therapy. Conclusions: Clinical outcome of the DUTCH PEERS trial at 2-year follow-up will be presented

    Impact of analyzing fewer image frames per segment during offline volumetric radiofrequency-based intravascular ultrasound measurements of target lesions prior to percutaneous coronary interventions

    Get PDF
    In the present study, we evaluated the impact of a 50% reduction in number of image frames (every second frame) on the analysis time and variability of offline volumetric radiofrequency-based intravascular ultrasound (RF-IVUS) measurements in target lesions prior to percutaneous coronary interventions (PCI). Volumetric RF-IVUS data of vessel geometry and plaque composition are generally obtained by a semi-automated analysis process that includes time-consuming manual contour editing. A reduction in the number of frames used for volumetric analysis may speed up the analysis, but could increase measurement variability. We repeatedly performed offline volumetric analyses in RF-IVUS image sets of 20 mm-long coronary segments that contained 30 de novo lesions prior to PCI. A 50% reduction in frames decreased the analysis time significantly (from 57.5 ± 7.3 to 35.7 ± 3.7 min; P < 0.0001) while geometric and compositional RF-IVUS measurements did not differ significantly from measurements obtained from all frames. The variability between measurements on the reduced number of frames versus all frames was comparable to the intra-observer measurement variability. In target lesions prior to PCI, offline volumetric RF-IVUS analyses can be performed using a reduced number of image frames (every second frame). This reduces the time of analysis without substantially increasing measurement variability

    Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis

    Get PDF
    Volumetric radiofrequency-based intravascular ultrasound (RF–IVUS) data of coronary segments are increasingly used as endpoints in serial trials of novel anti-atherosclerotic therapies. In a relatively time-consuming process, vessel and lumen contours are defined; these contours are first automatically detected, then visually checked, and finally (in most cases) manually edited to generate reliable volumetric data of vessel geometry and plaque composition. Reduction in number of cross-sectional images for volumetric analysis could save analysis time but may also increase measurement variability of volumetric data. To assess whether a 50% reduction in number of frames per segment (every second frame) alters the reproducibility of volumetric measurements, we performed repeated RF–IVUS analyses of 15 coronary segments with mild-to-moderate atherosclerosis (20.2 ± 0.2 mm-long segments with 46 ± 13% plaque burden). Volumes were calculated based on a total of 731 image frames. Reducing the number of cross-sectional image frames for volumetric measurements saved analysis time (38 ± 9 vs. 68 ± 17 min/segment; P < 0.0001) and resulted for only a few parameters in (borderline) significant but mild differences versus measurements based on all frames (fibrous volume, P < 0.05; necrotic-core volume, P = 0.07). Compared to the intra-observer variability, there was a mild increase in measurement variability for most geometrical and compositional volumetric RF–IVUS parameters. In RF–IVUS studies of mild-to-moderate coronary disease, analyzing less image frames saved analysis time, left most volumetric parameters greatly unaffected, and resulted in a no more than mild increase in measurement variability of volumetric data